dbx 1046 Quad Compressor Limiter User Manual

June 5, 2024
dbx

dbx logo

dbx 1046 Quad Compressor Limiter

MODEL 1046
PROFESSIONAL PRODUCTS 

A Harman International Company
OPERATION MANUAL

CAUTION
THE RISK OF ELECTRIC SHOCK DOES NOT OPEN

ATTENTION: RISQUE DE CHOC ELECTRIQUE – NE PAS OUVRIR

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE
The symbols shown above are internationally accepted symbols that warn of potential hazards with electrical products. The lightning flash with an arrow point in an equilateral triangle means that there are dangerous voltages present within the unit. The exclamation point in an equilateral triangle indicates that it is necessary for the user to refer to the owner’s manual.
These symbols warn that there are no user-serviceable parts inside the unit. Do not open the unit. Do not attempt to service the unit yourself. Refer all servicing to qualified personnel. Opening the chassis for any reason will void the manufacturer’s warranty. Do not get the unit wet. If the liquid is spilled on the unit, shut it off immediately and take it to the dealer for service. Disconnect the unit during storms to prevent damage.

WARNING
FOR YOUR PROTECTION, PLEASE READ THE FOLLOWING:

WATER AND MOISTURE: Appliance should not be used near water (e.g. near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through openings.
POWER SOURCES: The appliance should be connected to a power supply only of the type described in the operating instructions or as marked on the appliance. GROUNDING OR POLARIZATION : Precautions should be taken so that the grounding or polarization means of an appliance are not defeated.
POWER CORD PROTECTION : Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the appliance.
SERVICING: To reduce the risk of fire or electric shock, the user should not attempt to service the appliance beyond that described in the operating instructions. All other servicing should be referred to qualified service personnel.
FOR UNITS EQUIPPED WITH EXTERNALLY ACCESSIBLE FUSE RECEPTACLE: Replace the fuse with the same type and rating only.

U.K. MAINS PLUG WARNING

A molded mains plug that has been cut off from the cord is unsafe. Discard the mains plug at a suitable disposal facility. NEVER UNDER ANY CIRCUMSTANCES SHOULD YOU INSERT A DAMAGED OR CUT MAINS PLUG INTO A 13 AMP POWER SOCKET. Do not use the mains plug without the fuse cover in place. Replacement fuse covers can be obtained from your local retailer. Replacement fuses are 13 amps and MUST be ASTA approved to BS1362.

ELECTROMAGNETIC COMPATIBILITY

This unit conforms to the Product Specifications noted in the Declaration of Conformity.
Operation is subject to the following two conditions:

  • this device may not cause harmful interference, and
  • this device must accept any interference received, including interference that may cause undesired operation. Operation of this unit within significant electromagnetic fields should be avoided.
  • use only shielded interconnecting cables.

SAFETY INSTRUCTIONS

NOTICE FOR CUSTOMERS IF YOUR UNIT IS EQUIPPED WITH A POWER CORD.
WARNING: THIS APPLIANCE MUST BE EARTHED.
The cores in the mains lead are colored in accordance with the following code:

GREEN and YELLOW – Earth BLUE – Neutral BROWN – Live As the colors of the cores in the mains lead of this appliance may not correspond with the colored markings  identifying the terminals in your plug, proceed as follows:

  • The core which is colored green and yellow must be connected to the terminal in the plug marked with the letter E, or with the earth symbol, or colored green, or green and yellow.
  • The core which is colored blue must be connected to the terminal marked N or colored black.
  • The core which is colored brown must be connected to the terminal marked L or colored red. This equipment may require the use of a different line cord, attachment plug, or both, depending on the available power source at installation. If the attachment plug needs to be changed, refer servicing to qualified service personnel who should refer to the table below. The green/yellow wire shall be connected directly to the unit’s chassis.
CONDUCTOR WIRE COLOR
Normal Alt
L LIVE
N NEUTRAL
E EARTH GND

WARNING: If the ground is defeated, certain fault conditions in the unit or in the system to which it is connected can result in full line voltage between chassis and earth  round. Severe injury or death can then result if the chassis and earth ground are touched simultaneously.

DECLARATION OF CONFORMITY

Manufacturer’s Name:
Manufacturer’s Address:| dbx Professional Products
8760 S. Sandy Parkway Sandy, Utah 84070, USA
---|---

declares that the product dbx 1046 conforms to the following Product Specifications:

Safety:  60065 (1993)IEC 65 (1985) with  Amendments 1, 2, 3
EMC:  55013 (1990)

55020 (1991)

Supplementary Information:

The products herewith comply with the requirements of the EMC  Directive 89/336/EEC (1989), as amended by the CE marking directive 93/68/EEC (1993).

dbx  Professional Products   President 8760 S. Sandy Parkway Sandy, Utah 84070, USA April 22, 1996
European Contact: Your local dbx Sales and Service Office or Harman Music Group
8760 South Sandy Parkway Sandy, Utah 84070 USA
Ph: 801-566-8800 Fax:801-568-7583

Introduction

Congratulations and thank you for your purchase of the dbx 1046 Quad Compressor Limiter. The dbx 1046 is a high-performance multifunctional unit designed to deliver all the flexibility and power that a professional user demands. The dbx 1046 incorporates the new advanced dbx V2™ VCA for high system performance. We recommend you take a moment to read through this Operation manual. It provides information that will assist you in system set- up.

Inspection

Verify that the 1046’s package contains the following:

  • 1046 Unit (according to Model number marked on the package)
  • AC Power Cord
  • Operation Manual
  • Registration Card
  • 4 Rack Mount Screws and Washers
    If any of these items are missing, contact dbx customer service at 801-568-7660.

Warranty

  1. The warranty registration card that accompanies this product must be mailed within 30 days after the purchase date to validate this warranty. Proof of purchase is considered to  e a burden of the consumer.
  2. dbx warrants this product, when bought and used solely within the U.S., to be free from defects in materials and workmanship under normal use and service.
  3. dbx liability under this warranty is limited to repairing or, at our discretion, replacing defective materials that show evidence of defect, provided the product is returned to  bx WITH RETURN AUTHORIZATION from the factory, where all parts and labor will be covered up to a period of two years. A Return Authorization number must be obtained from dbx by telephone. The company shall not be liable for any consequential damage as a result of the product’s use in any circuit or assembly.
  4. dbx reserves the right to make changes in design or make additions to or improvements upon this product without incurring any obligation to install the same additions or improvements on products previously manufactured.
  5. The foregoing is in lieu of all other warranties, expressed or implied, and dbx neither assumes nor authorizes any person to assume on its behalf any obligation or liability in connection with the sale of this product. In no event shall dbx or its dealers be liable for special or consequential damages or from any delay in the performance of this arranty due to causes beyond their control.

Connecting 1046 to your system

To connect 1046 to your system, refer to the following steps:

  • Turn off all equipment before making any connections.

  • Mount 1046 in a rack
    Install 1046 in a rack with the rack screws provided. It can be mounted above or below anything that does not generate excessive heat. Ambient temperatures should to exceed 113˚ F (45˚ C) when equipment is in use. Although the unit is shielded against radio frequency and electromagnetic interference, extremely high fields of RF and  MI  should be avoided.

  • Make audio connections via XLR, 1/4” TRS, or 1/4” TS plugs.
    Both types of connectors for the inputs and outputs can be used for balanced or unbalanced connections. The use of more than one connector at a  time for the input/output pair could unbalance balanced lines, cause phase cancellations, short a conductor to ground, or cause damage to other equipment connected to 1046.

  • Apply power to the 1046
    Connect the AC power cord to the AC power receptacle on the back of the unit. Route the AC power cord to a convenient power outlet away from  udio lines. The unit may be turned on and off via the rear panel power switch or from a master equipment power switch.

Operating Controls

Front Panel
Gain Reduction Meter – This 8 stage meter shows the amount of gain reduction due to both  compression and/or Intelligent Predictive Limiting™, displaying gain reduction from 0 to 30 dB.

dbx 1046 Quad Compressor Limiter - Front Panel
Compressor Threshold Control – This control sets the level above which compression occurs, and has  a 60 dB range.
OverEasy® Switch – OverEasy® provides a smooth transition from the compressor’s linear region to the compressed region. This smooth transition greatly reduces compression artifacts and allows higher compression ratios while still maintaining the natural characteristics of the signal. The switch lights indicate OverEasy® processing is enabled. When conventional hard knee processing is desired, disable the OverEasy® function. See Figure 1 below.
Figure 1: Hard Knee Compression Curve and OverEasy® Compression Curve.

dbx 1046 Quad Compressor Limiter - Figure
Compressor Ratio Control – This control selects the ratio between input and output levels for signals above the level set by the COMPRESSION THRESHOLD control. It is adjustable between 1:1 and ∞:1. Note, when OverEasy® processing is selected, the ratio transitions smoothly from the linear to the compressed region. As the signal exceeds the threshold, the ratio approaches the ratio set by the COMPRESSOR RATIO control.

Figure 2 shows the effect of 2:1 compression on a signal as it rises above and falls below the threshold. Below the threshold, the signal is not affected. Above the threshold, the output signal increases by only half of the increase (in dB) of the input signal level. In other words, with a 2 dB increase in input level, the output increases by only 1 dB, hence the 2:1 compression ratio.

dbx 1046 Quad Compressor Limiter - Signal Signal Level (dBu) Signal Level (dBu

Figure 2: Compression Effect on Signal Level with a 2:1 Ratio at a -20 dBu Threshold

Input/Output Level Meter – This 8-stage meter directly reads the input and output levels when the rear panel OPERATING LEVEL SWITCH is in the  4 dB position. In the -10 dBV position, the input signal is boosted by 11.8 dB (the difference between +4 dBu and -10 dBV) to convert a semi-pro -10  BV  level signal to the professional +4 dBu internal level of 1046, while the output signal is attenuated by 11.8 dB to convert back to a -10 dBV level.  ince the meter is calibrated for +4 dBu operation, it reads about 12 dB higher than the actual input and output signal levels when the OPERATING  EVEL  WITCH is set to -10 dBV.

Input/Output Meter Switch – This switch selects the signal for metering by the INPUT/OUTPUT LEVEL

Operating controls

METER. The switch lights indicate the input signal is currently being sent to the meter. When the switch is in the out position, the output signal is selected for metering, and the switch will not be illuminated.

Output Gain Control – This control sets the output gain of the compressor. It can be continuously adjusted between -20 dB and +20 dB. Use this control to compensate for the signal level loss due to compression and to adjust the nominal output level of the unit.

Bypass Switch – This switch bypasses the unit completely, “hard-wiring” the input directly to the output, and the signal is not processed in any way. The switch will light indicating that the unit is currently bypassed.

PeakStopPlus™ Level Control – This control sets the level to which the output signal is reduced whenever it exceeds this level. It can be adjusted between +4 dBu and +22 dBu (OFF). This PeakStopPlus™ limiter uses a proprietary dbx two-stage limiting process. The first stage is the Instantaneous Transient Clamp™ which clamps the signal with a soft logarithmic clamp function. This logarithmic function assures that the signal will not exceed the level set by the PeakStopPlus™ LEVEL control by more than 2 dB typically and that it will not introduce harsh artifacts. The second stage is a unique program limiter featuring Intelligent Predictive Limiting™. Its function is to monitor the input signal and intelligently predict the amount of gain reduction needed to keep the output signal below the ceiling set by the Instantaneous Transient Clamp™. The PeakStopPlus™ limiter must come after the OUTPUT GAIN control. If the OUTPUT GAIN is set too high as compared to the PeakStopPlus™ LEVEL control, continuous limiting can occur. While PeakStopPlus™ is typically used as a protective function, creative effects can be achieved by intentionally driving the signal into heavy PeakStopPlus™ limiting. Great care has gone into the design of the PeakStopPlus™ limiter to keep it acoustically transparent. Appropriate use of it can protect your gear while keeping the signal free of artifacts.

PeakStopPlus™ Threshold (+) LED Indicator – This LED illuminates when the output signal exceeds the level set by the PeakStopPlus™ LEVEL control indicating that PeakStopPlus™ limiting is occurring.

Figure 3 illustrates the protective action of the PeakStopPlus™ limiter. The signal with the thin line weight represents an unaltered input signal. As you can see, peaks of the input signal exceed the clamping level. The signal with the heavier line weight represents the output signal. The peaks of the input signal which exceeded the clamping level are not allowed to exceed this level at the output. This instantaneous protective action is invaluable for driver protection in speaker systems and for digital recording where it is desirable to record as “hot” as possible, while still avoiding the disastrous result of running out of headroom. Following this clamping action, Intelligent Predictive Limiting™ takes over, typically within 5ms, as long as the input signal continues to exceed the PeakStopPlus™ threshold. This program limiter quickly attenuates the input signal to a level safely below the clamping level, typically 2 dB lower than the clamping level. The PeakStopPlus™ level control is calibrated to this lower level, so if an absolute ceiling is required, set the level 2 to 3 dB below the front panel setting.

The attack and release times of the Instantaneous Transient Clamp™ are zero, while the Intelligent Predictive Limiting™ attack and release times are program-dependent. That is, for larger excursions over the threshold, the attack time speeds up, and for smaller excursions over the threshold, the attack time slows down. Similarly, for large excursions over the threshold which cause more PeakStopPlus™ gain reduction, the release time increases and is roughly proportional to the amount of gain reduction that occurred.

dbx 1046 Quad Compressor Limiter - Output Signal

Stereo Couple Switch – These switches change 1046 from four independent compressors into two stereo compressors. In stereo mode, Channel 1 is the master and Channel 2 is its client, Channel 3 is the master and channel 4 is its client. Each of the Channel 2 and 4 controls and switch functions will be overridden and controlled by the Channel 1 and 3 controls and switches, respectively, except for the I/O Meter and Bypass switches. Also, Channel 2’s and 4’s Compressor Threshold, and PeakStopPlus™ Threshold meters will be disabled, while these client channels’ Gain Reduction meters will indicate the amount of gain reduction occurring, as on their masters’ Gain Reduction Meters. All 4 channels have equal precedence as far as signal processing is concerned. The dbx 1046 uses True RMS Power Summing™, an extremely accurate and musical way to combine detector outputs in a stereo situation. The switch will light to indicate that 1046 is in the Stereo Couple mode.

Rear Panel Operations

Rear Panel
dbx 1046 Quad Compressor Limiter - Rear Panel

AC Power Receptacle – Use the supplied AC cable to connect the unit to AC power. The AC receptacle includes an integral pull-out fuse drawer that contains two fuses; the active fuse and a spare fuse. Replace the fuse with the same type and rating only.as indicated on the rear panel.
Audio Inputs – Each channel features both XLR and 1/4” TRS electronically balanced inputs. Inputs may be used in a balanced or unbalanced configuration.
Note that the XLR and 1/4’ inputs may NOT be used simultaneously.
Audio Outputs – Each channel features both XLR and 1/4” TRS servo- balanced outputs. Outputs may be used in a balanced or unbalanced configuration. like the inputs of both the XLR and the 1/4” outputs may be used simultaneously.
Operating Level Switch – This switch selects between a -10 dBV and +4 dBu nominal operating level. When the switch is in the in position, a -10 dBV operating level is selected. When it is in the out position, +4 dBu is selected. This switch affects both the input and the output levels.

Applications

Fattening Kick Drums and Compressing Other Drums Weak, flabby kick drums often have too much boom and not enough slap. To tighten them up, start with the 1046 adjusted for a medium to high RATIO (e.g., 6:1), adjust the THRESHOLD control so that the GAIN REDUCTION meters show 15 dB of gain reduction, then increase the RATIO if necessary. In OverEasy® mode, 1046 takes slightly longer to react than in Hard Knee mode, and will therefore emphasize the slap at the beginning of the note and reduce the boominess of its body. 1046 also works well for tightening snare drums and tom-toms and can be used with drum machines to effectively alter the character of any electronic drum sound.

Raising a Signal Out of a Mix
Since reducing dynamic range increases the average signal level by a small amount, a single track can be raised out of a mix by boosting its level slightly and applying compression. Start with a 2:1 RATIO and a relatively low THRESHOLD setting (-20 dBu). Adjust both controls as necessary. Compressors have lso been used to bring vocals to the forefront of a mix in volume- restricted studios (e.g. home studios). Start by adding a foam windscreen to the mic (if it  oesn’t have one). Set the RATIO to 10:1 and the THRESHOLD to -10 dBu. With your mouth approximately 2 inches from the mic, sing the vocal part, but ith less volume than normal. Use phrasing to give the part some intensity. An equalizer (e.g., a dbx 242 Parametric Equalizer, dbx 30 Series Graphic equalizers) or a vocal effects device (e.g., a dbx 290 digital reverb) can be added to further define the performance.

Note: When compressing a stereo program with a 1046, the factors affecting a compression curve and the actual RATIO and THRESHOLD settings are the same as those previously covered with reference to single channels of program material. However, it will generally be found that large amounts of compression are more audible in a mixed stereo program than they might be on the separate tracks that were mixed to create the program.

Smoothing out Microphone Levels
When distance is created between the vocalist and the microphone there will be a variation in the signal level. Start with low compression (around 2:1) to smooth out any variations. Limiting also benefits intelligibility by allowing low-level input signals to be reproduced through the system at a higher volume.

Smoothing out Musical Instrument Levels
Compression smooths out the variations of loudness among instruments. Using 1046 can also increase the instrument’s sustain. Compress the instrument’s output with a ratio of about 4:1.

Speaker Protection
Compressors are frequently used to prevent excessive program levels from distorting power amps and/or damaging drivers in a sound-reinforcement system (whether you’re doing auditorium, church, or club sound engineering, or are a mobile DJ, or like to push the limits of your home’s audio entertainment center). Set 1046 for limiting (Hard Knee mode On, with a RATIO of 10:1 or greater) and adjust the THRESHOLD to provide 15 dB or more of compression (just a few dB below the input clip). For low-level signals, 1046 won’t change again, but if large signals come along, the gain will be reduced to prevent clipping and save sensitive system components from excessive heat buildup or other types of damage.

Note: PeakStopPlus™ Limiting can also be used to prevent speaker damage.

Preventing Digital Recording Overload
Some digital recorders and samplers produce audible distortion when they exceed their maximum operating level. 1046 can be used to ensure that audio nput does not overload a digital recorder’s A/D (analog-to-digital) converters. 1046 can perform this function quietly enough for all digital media. To use 1046 so that no changes in gain occur unless an emergency arises (wildly excessive levels), set Hard Knee mode On, the RATIO to ∞:1,  nd the THRESHOLD highest level before digital overload.

Note: PeakStopPlus™ limiting can also be used to prevent raucous-sounding digital overload.

Installation Considerations

Hookups and Cabling: 1046 is designed for nominal -10 dBV or +4 dBu levels. 1046 can be used with either balanced or unbalanced sources and the outputs can be used with either balanced or unbalanced loads, provided the proper cabling is used.

Normal Balanced Connections for Inputs and Outputs

Connection XLR TRS 1/4″ Jack
Ground: Pin 1 Sleeve
High: Pin 2 Tip
Low: Pin 3 Ring

Connection
Ground:
High:
Low (ground):| XLR
Pin 1
Pin 2
Pin 3| TRS 1/4” Jack
Sleeve
Tip
Ring| TS 1/4” Jack
Sleeve
Tip
Sleeve
---|---|---|---

Tie pin 3 to the ground for unity gain in/out of 1046 when using unbalanced input connections to balanced output connections or balanced input connections to unbalanced output connections. To do otherwise won’t hurt the unit but will result in unmatched input to output levels, and the level control will not be properly calibrated.