Alecto SA-300 Smoke Detector for Domestic User Manual

June 5, 2024
Alecto

Alecto SA-300 Smoke Detector for Domestic User Manual

Alecto SA-300 Smoke Detector for Domestic

The SA-300 is a smoke detector set for discovery of fire in the first stage. If smoke develops, the SA-300 will give a loud beep of at least 85dB (A). As part of the link function all the smoke alarms within range will sound the alarm. We advice to test the smoke detectors weekly using the test button on the detectors. Save this manual in a safe place or inside of the electricity meter cupboard.

RECOMMENDED INSTALLATION LOCATIONS FOR THE SA-300:

  • Install the first smoke detector near the bedroom. Ensure that it is placed so, if it would detect fire, at least one exit route would still be accessible. We recommend to place one alarm near each potential blockade of your exit route, so you are alerted before a fire would block off escape.
  • Use multiple smoke detectors to increase safety and ensure an alert before the escape route is blocked.
  • Install at least one smoke detector on each floor of your house.
  • Install at least one smoke detector in each room where people smoke or where there is equipment that may potentially cause a fire.
  • Smoke and heat will first move upwards towards the ceiling; after that the smoke and heat will travel horizontally.
  • Install the detector on the ceiling. Except for rooms smaller than 1m, you should stay at least 50 cm away from the wall and 61cm from any corner. Smoke and heat do not gather in such corners, preventing the detector from alerting you on time.

DO NOT INSTALL IN THE FOLLOWING LOCATIONS:

  • The kitchen; Steam from cooking might give a false alarm.
  • The shower or bathroom; water damp might cause a false alarm and the moist environment might damage the detector.
  • The garage: The car exhaust might cause a false alarm.
  • In front of a fan or nearby the exhaust of an air conditioner or heater.
  • In a ceiling nook.
  • In rooms where the temperature could reach below -10°C or beyond 40°C.
  • Do not paint or otherwise cover this smoke detector.

INSTALLATION INFORMATION:

Attach the ceiling plate using the included plugs and screws to the ceiling on a location of choice. Wall mounting is not recommended for smoke detection. Then put the detector to the ceiling plate and, twist clockwise to lock it in place. It will emit a beep and be ready for use. Perform a first test by holding the key for three seconds. Also see the paragraph: “Testing

USING, TESTING AND MAINTENANCE:

Using:

The smoke detector works if the smoke detector has been mounted to the ceiling. A red LED will light up and the smoke detector will beep briefly to let you know that it has been activated, because the ceiling plate has switched a lever on the inside.
The red LED will now flash every 40 seconds. Once smoke is detected, the alarm will sound. Once the smoke disappears, the smoke alarm will stop automatically.

Test:

Hold the button for at least 3 seconds. The operation is still correct if you hear 2 or three signal tones. Check the smoke detectors weekly. In alarm status the smoke detector
will generate about 85dB(A). Do not use candles, open fire or cigarettes to test the smoke detector.

Time-out function:

This function will deactivate the alarm for about 10 minutes. This function can be enabled by pushing the HUSH/TEST button very shortly. The LED will now blink once every 8 seconds to indicate the deactivated smoke alarm. After 10 minutes, the alarm will be fully active once again. If there is (still) any smoke in the environment, the alarm will go off again.
This function can be used repeatedly.

ATTENTION:

  • If the cause of an alarm is unclear, assume it’s caused by fire. Immediately evacuate the building.
  • Keep the smoke detectors out of range of children.
  • Protect against dust during rennovations. Without protection the smoke detectors will lose their functionality.

Maintenance:

The smoke detector is maintenance-free. In very dusty rooms they may be cleaned by vacuum.

PLAN AN ESCAPE ROUTE:

  • Make a map and mark all locations of doors and windows and a possible escape route. Note that you may need an escape ladder on high floors.
  • Ensure everyone in the house knows the sound the smoke alarms produce and regularly practice use of the escape route.
  • Leave the house immediately according to the plan when hearing the alarm. Every second counts: so respond quickly. If you do not notice smoke or heat, check if everyone in the house is in a secure location.
  • Do not open any doors without feeling wether the door is warm or if there is smoke coming from underneath the doors. If it is, do not open that door. If the door is cold, put your shoulder firmly against the door and open it a small amount to check for any heat or smoke first.
  • If there is much smoke, keep low and take shallow breaths, preferably through a moist towel. Call the fire department as soon as you are safe outside.

REPLACING THE BATTERIES:

The detector is supplied using a built-in lithium battery. Under normal conditions the battery will last at least ten years. If the detector is about to need replacement, the smoke detector will make a chirping sound every 40 seconds for at least 30 days. If the smoke detector does not function, please contact your supplier.

ENVIRONMENT:

Do not throw away used batteries, but recycle them using your local chemical depot. Product may not be thrown out as normal waste, but must be recycled as electrical waste.

DECLARATION OF PERFORMANCE:

Is available at the following internet address: http://DOC.hesdo.com/SA- 300_DOP_1.pdf

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals