QUNBAO QD3632B 4-Channel Soil Temperature and Humidity Recorder User Manual
- June 5, 2024
- qunbao
Table of Contents
- QUNBAO QD3632B 4-Channel Soil Temperature and Humidity Recorder
- Technical Parameters
- Product Size
- How to wiring?
- Application solution
- Rapid measurement
- Buried measurement method
- How to use?
- KEY POSITION& SCREEN DISPLAY DESCRIPTION
- Disclaimer
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
QUNBAO QD3632B 4-Channel Soil Temperature and Humidity Recorder
QD3632B using the standard USB,easy access to PLC,DCS and other instruments or systems for monitoring temperature,humidity state quantities.The internal use of high-precision sensing core and related devices to ensure high reliability and excellent long-term stability,can be customized RS232,RS485,CAN,4-20mA,DC0~5V\10V,ZIGBEE,Lora,WIFI,GPRS and other output methods.
Technical Parameters
Technical parameter | Parameter value |
---|---|
Brand | TRANBALL |
Temperature measuring range | -30℃~80℃ |
Temperature measuring accuracy | ±0.5℃ @25℃ |
Humidity measuring range | 0~100%RH |
Humidity accuracy | ±3%RH @25℃ |
Communication Interface | USB |
Default baud rate | 9600 8 n 1 |
Power | DC3.3~4.2V |
Storage | 512000bits |
Running temperature | -40~80°C |
Working humidity | 5%RH~90%RH |
Product Size
How to wiring?
Note : When wiring, connect the positive and negative poles of the power supply first, and then connect the signal vwire.
Application solution
A: After opening the software, enter the main interface, select the
corresponding product model at the time of purchase, and save the settings
after selection, in case you need to reselect it after opening it next time.
B: Use the USB converter to insert the computer’s USB2.0 interface, the
driver will be installed automatically,
If the installation fails, you can install it in the driver wizard software.
After connecting to the computer,
Select the serial port number: USB-SERIAL CH340 (COM5),set the baud rate
Click to open the serial port to complete the connection.
CD: After opening the serial port, click online collection (C) to see the
real-time measurement data (D).
E: Enter the parameter setting interface
F: A variety of parameters can be set in the parameter setting, such as
temperature and humidity correction, baud rate, upload time and other
parameters. For the parameters on the right, you can click on “read all” to
set the parameters on the recorder.
G: Enter the record operation interface
H: Click “Read Data” to start transferring the data on the recorder to
the software.
I: After the step (H), the number of reading data, the total number of
data, and the number of pages will be displayed at the top of the reading.
J: The read data will be displayed on it
K: You can export the read data in Excel or text format
Single module application scheme
Multi-module application scheme
Rapid measurement
Choose a suitable measurement location, avoid rocks, cut the surface soil according to the depth required for measurement, maintain the original tightness of the underlying soil, hold the sensor vertically and insert it into the soil.
Buried measurement method
Dig a pit with a diameter of about 20cm vertically, and insert the sensor needle into the pit horizontally according to the measurement requirements, and fill the pit to ensure close contact with the soil. After the sensor is stable for a period of time, continuous long-term measurement and recording can be carried out
How to use?
KEY POSITION& SCREEN DISPLAY DESCRIPTION
-
Upload interval display, up to 100 seconds can be set This item is set by SET
-
When the button is pressed, when the icon becomes the timing stops on the left
When the button is pressed, when the icon becomes the timing starts on the left -
Number of records: The number of records will be increased once at the end of the countdown on the left
Press “SET” to enter the clock setting Use to shift, adjust the value up and down
Press the second “SET” to enter the storage interval setting
The upper limit can be set to 100 seconds/time
Press the third “SET” to enter the record start point setting The upper limit can be set to 65101
Disclaimer
This document provides all information about the product, does not grant any license to intellectual property, does not express or imply, and prohibits any other means of granting any intellectual property rights, such as the statement of sales terms and conditions of this product, other issues. No liability is assumed. Furthermore, our company makes no warranties, express or implied, regarding the sale and use of this product, including the suitability for the specific use of the product, the marketability, or the infringement liability for any patent, copyright or other intellectual property rights, etc. Product specifications and product descriptions may be modified at any time without notice.
Contact Us
Company: Shanghai Sonbest Industrial Co., Ltd TRANBALL Brand Division Address:
Building 8, No.215 North east road, Baoshan District, Shanghai,China Web:
http://www.qunbao.com
Web: http://www.tranball.com
SKYPE: soobuu
Email: sale@sonbest.com
Tel: 86-021-51083595 / 66862055 / 66862075 / 66861077
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>