4lite GU10 Fire Rated Downlight Gimbal Instruction Manual

June 5, 2024
4lite

4lite GU10 Fire Rated Downlight Gimbal

4lite-GU10-Fire-Rated-Downlight-Gimbal-PRODUCT

Installation Instruction

General Installation Instructions
These instructions should be read carefully prior to any installation and retained after completion for further reference and maintenance. Please give these instructions to the building owner/occupier after installation.

Important Safety

  1. Before installation, maintenance, or lamp replacement, ensure that the mains supply to the luminaire is switched off and the circuit supply fuses are removed or the circuit breaker is turned off is recommended that only a qualified electrical contractor carries out the installation of this luminaire and that the luminaire is installed in compliance with the current edition of the IEE Wiring
  2. Regulations The person carrying out the installation is to check and verify that the total load on the circuit, including that of this luminaire, does not exceed the rating of the circuit cable, fuse, or circuit breaker Where a luminaire incorporates discharge control gear (inductive load), the circuit o avoid nuisance tripping of the protective device used in the installation.
  3. Where a luminaire incorporates discharge control gear (inductive load). the circuit capacity and ratings require careful sizing to avoid nuisance tripping of the protective device used in the installation
  4. Where applicable, careful consideration should be taken during installation to ensure that all fixings and/or suspensions are of a suitable size for the luminaire being installed.

Ratings

  1. All luminaires are manufactured & tested in compliance with the requirement contained within BS EN 60598 and are CE marked.
  2. All luminaires that are of Class 1 construction and that are marked accordingly, MUST be earthed
  3. All luminaires are designed to operate at 230Volts AC 6%/+10% 216Vots to 252Volts. Do not operate outside these voltages
  4. All luminaires are only suitable for applications within their rated Ingress Protection limits as stated.
  5. This luminaire is designed for internal use only.

Exclusions to Warranty
Please Note: The limited warranty shall be null and void in the following circumstances Failure by the installer, end-user, or any third party to exercise caution to protect any covered product or part from outside damage, adverse temperature (normal operating ambient temperature 0-25°C), humidity conditions, fluctuations in the electrical system or physical abuse as well as failure related to the workmanship in the installation of the products or parts.

Installation

Select a suitable mounting location to install the luminaire. Care should be given to ensure adequate ventilation for the luminaire as this luminaire operates at high temperatures. Check that sufficient depth is available in the ceiling void and there is adequate free air ventilation around the luminaire Ensure the luminaire is not located in close proximity to ceiling joists, electrical cables, and pipe work or insulation materials. Luminaires should not be installed where the illuminated surface is within 0.Sm from the front of the fitting. Cut an 80mm diameter round hole in the ceiling material. This luminaire is suitable for installation in ceiling material thicknesses from 10mm to 25mm. GU10 Mains (230V) Terminate the 230V supply cable max 2 x 1.5mm loop in-Loop out, ensuring the correct polarity is observed. This luminaire is designed to accept up to a 50W GU10 Lamp.
THIS LUMINAIRE IS CLASS I CONSTRUCTION USED WITH GU10 LED MAINS LAMPS, AND MUST BE EARTHED
offer the luminaire through the aperture, bend back the springs and push gently into the ceiling. Do not install the luminaire onto new plaster or wet paint. Remove the Twistiock lamp retaining ring by twisting it in an anti- clockwise direction. Insert the appropriate lamp type, and position the lamp into the retaining clip. Return the retaining ring into the luminaire housing and twist firmly in a clockwise direction to lock the ring into position. Restore the power supply. switch on and test for correct operation. Important Installation Advice: It is recommended to allow a void of space around the downlight. When used with 50W GU10 not suitable to be installed into flammable material.

Maintenance

  1. Lamp Cap GU10. Maximum wattage 50w
  2. 4Lite recommends the use of recognized branded lamps Disposal of Electronic Equipment WEEE Directive 2002/96/EC This product falls within the scope of the Waste Electrical & Electronic
  3. Equipment Directive (WEEE), which means the product should not be disposed of as normal household waste.
  4. Ensure that this luminaire and lamp are disposed of in accordance with the WEEE Directive.
  5. Contact a local Council Waste Dept. Local Amenity Site, or the Environment Agency for further information. RoHS All components and materials used in this product are RoHS 2002/95/EC compliant

Wireless specification

Wireless RF mode frequency bendt 2400-24835 MH Maximum transmitted power 20 dBm Operating channels Wi-Fi 13/9 channel Operating channels Bluetooth 40 channels Products shall not be used with dimmers for dimming ue the WiZ application On/off functionality available without Wi-Fi connectivity W-Fi is registered trademark of Wi-Fi Alliance WPA s a trademark of W-Fi Alliance WPA2 I trademark of Wi-FYI Alliance. Tne Wi-Fi CERTIFIED TM Logo is e certification mark of Wi-Fi Alliance Amazon, Alee and all related logos are trademarks of Amazon.com./nc or its effects Google is a trademark of Google LLCSini is a registered trademark of Apple Inc The Bluetooth word end logic ere registered trademarks owned by Bluetooth SIGINT Hereby [WZ Connected Lighting Co, Limited] declares that the radio equipment type WIZ Performance lempe]s in compliance with Directive 2014/53/EU The full text of the EU declaration of conformity is available at the following internet address wizconnected.com

QUICK USER GUIDE

  • INSTALL YOUR PRODUCT
  • DOWNLOAD THE Wiz APP
  • FOLLOW THE EASY GUIDE ON THE APP
  • ENJOY YOUR CONNECTED LIGHTS

TROUBLESHOOTING

My lights won’t pair in the Wiz Connected App. For an optimal pairing experience with Wiz Connected products, make sure your WiFi router is operating on 2.4GHz or alternatively follow the in-App support to pair the products manually or chat with the support team.

Check that the lamp or bulb is within Wi-Fi range. Check that your phone is connected to the 2.4 GHz Wi-Fi on your home router. You can switch back to 5 GHz after pairing is done. Follow the prompts on your app screen. How do I make sure my lights are in pairing mode? When you repeatedly power ON your light, it should start to pulse in blue (color light) or white (tunable white or dimmable light). The pulsing means your light is ready to pair f no light is found, try Manual Setup l am not sure how to connect to the 24 GHz network. What should I do? Tap on Try manual setup. Wait for the next screen to open and follow the instructions, which will make you open the Wi-Fi settings of your phone and connect to WiHF WIZConfig XXXX When the light is in Manual Setup mode and emits a W-Fi signal it will pulse in purple (color light) or white (tunable white or dimmable light). Still, having problems? Cantact suppart team via in-app chat.

Warning: Dimmer switches are not supported by WiZ lights and may damage the product. f you want to use it regardless, make sure the dimmer is at 100s Tip! Metallic/enclosed shades or fixtures may hamper connectivity.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals