Mimaki UJF-3042MKII Desktop Size UV LED Flatbed Printer Instruction Manual

June 5, 2024
Mimaki

Mimaki UJF-3042MKII Desktop Size UV LED Flatbed Printer

Instruction Manual

Before using

For note and safety, refer to the instruction manual of the UJF- 3042MkIIseries/6042MkIIseries printer. Before using, be sure to read the “Warning and Note” of this manual and fully understand its contents. The unauthorized reproduction of any portion of this document is strictly prohibited.
© 2016 MIMAKI ENGINEERING Co., Ltd. It is recommended to check the effect of removing electricity in advance.

  • It is possible that enough effect cannot be achieved depending on your user environment or the media.
  • Do not touch directly on the electrode probe during use or in the middle of static elimination. There is a risk of injury. Please work with care.
  • Do not touch the electrode probe in hard material, such as a tool during use or in the middle of static elimination. This may cause a malfunction or accident.

Setting the Ionizer

When setting the ionizer “ON” in the MACHINE SETUP, it will perform the static elimination operation before print.

  1. Press (MENU) ( > >) in local.
  2. Press to select “MACHINE SETUP” and press the key.
  • MACHINE SETUP MENU will be displayed.
  1. Press to select “IONISER” and press the key.
  • The “IONISER” setting will be selected.
  1. Press to select “ON” and press the key.
  • When set to “ON”, the table moves the entire surface according to the print data in order to eliminate static prior to print.
  1. Press the key several times to end the setting.

About daily care

  • Before taking care of it, be sure to turn off the main power switch of the main body.
  • You may get an electric shock. Also, you may get injured collaterally.
  • Do not touch the electrode probe directly. You may get injured. Be careful to work.
  • After cleaning, fully dry it and then attach it to the ionizer to use.
  • When washing liquid remains on the electrode probe, it may cause an accident or failure of the machine. The cleaning alcohol may touch your skin or get in your eyes.
  • Do not touch the electrode probe with a hard thing such as a tool. It may cause an accident or failure of the machine.

Tools required for maintenance

  • Electrode Probe Cleaning Kit (SPA-0237/SPA-0239)
  • Goggles
  • Alcohol
  • Gloves

Cleaning the Electrode Probe

Check the electrode probe before operation and clean it if it is dirty.

  • Do not touch the electrode probe directly. You may get injured. Be careful to work.
  • Do not touch the electrode probe with a hard thing such as a tool. It may cause an accident or failure of the machine.

Remove the electrode probe from the ionizer.

  • By using the attached electrode probe replacement kit, you can remove it easily.
  1. Put the replacement kit to the electrode probe.
  2. Remove the electrode probe.

Wipe off the electrode probe and around it with a cotton swab immersed in alcohol

  • Recommended: ethyl alcohol.

When it is very dirty

  • Use an ultrasonic bath. Also, you can use alcohol as a washing liquid.

Clean with Electrode Probe Cleaning Kit (SPA-0237)

Explain how to clean using Electrode Probe Cleaning Kit (SPA-0237).

  • Do not touch the electrode probe directly. You may get injured. Be careful to work.
  • Do not touch the electrode probe with a hard thing such as a tool. It may cause an accident or failure of the machine.
  1. Soak the filter of the electrode probe cleaning kit for the cleaning unit in alcohol.
  2. Cover the electrode probe cleaning kit, and gently turn it two or three times.
  • The filter of the electrode probe cleaning kit wipes away stains on the electrode probe.
  • If it is very dirty, replace the filter and clean it again.

Soak the Electrode Probe Cleaning Kit

  • Lids are included with the cleaning kit to prevent dust from entering the cleaning kit during storage. Always put the lids on when storing.
  • Also, a cord can be passed through the strap hole so that the kit can be hung on a wall. Be sure to put on the lids during this storage method as well. (Please prepare a strap on your own.)

Installing the Filter

Explain the filter exchange method of the Electrode Probe Cleaning Kit (SPA-0237).

Cleaning Kit Replacement Filter

  • After the filter is used to clean multiple electrode probes, dust becomes attached to the filter and the cleaning abilities are reduced.
  • If the filter is dirty, replace with Electrode Probe Cleaning Kit included instead filter or exchange it for an optional cleaning kit of filters, (SPC-0238).
  1. Remove the used filter and insert the new filter into the hole at the center of the electrode probe cleaning kit.
  • Be careful of the way the filter is facing. Install the filter with the hole side up.
  1. Push the filter all the way into the cleaning kit.
  • Mounting position of the filter to be set in ±1mm to the end faces.
  • Push the filter completely inside to prevent it from bending.

Clean the electrode inner wall

Electrode Probe Cleaning Kit 2 (SPA-0239) is used to clean the inner wall of the electrode probe cap. When clean the tip of the electrode Probe, please use Electrode Cleaning Kit (SPA-0237).

Tools required for maintenance

  1. Electrode Probe Cleaning Kit 2 (SPA-0239)
  2. Goggles
  3. Alcohol
  4. Gloves
  • Do not touch the electrode probe directly. You may get injured. Be careful to work.
  • Do not touch the electrode probe with a hard thing such as a tool. It may cause an accident or failure of the machine.
  1. Soak the filter of electrode probe cleaning kit 2 for the cleaning unit in alcohol.
  2. Cover the electrode probe cleaning kit 2, and gently turn two or three times.
  • The filter of electrode probe cleaning kit 2 wipes away stains on the electrode probe.
  • If it is very dirty, replace the filter and clean it again.

Installing the Filter

Explain how to replace the filter of Electrode Probe Cleaning Kit 2(SPA-0239).

Cleaning Kit 2 Replacement Filter

  • After the filter is used to clean multiple electrode probes, dust becomes attached to the filter and the cleaning abilities are reduced.
  • If the filter is dirty, replace it with Electrode Probe Cleaning Kit 2 included instead filter or exchange for optional cleaning kit of filters, (SPC-0240).
  1. Remove the used filter and insert the new filter into the hole at the center of the electrode probe cleaning kit 2.
  • Be careful of the way the filter is facing. Install the filter with the diagonal tip side up.
  1. Push the filter using tweezers all the way into the electrode probe cleaning kit 2.
  • The mounting position of the filter is to be set between 0 to 2mm to the end faces.
  • Push the filter completely inside to prevent it from bending.

Alarm output function

This ionizer has the function to output alarms.

Alarm output partMimaki-UJF-3042MKII-Desktop-Size-UV-LED-Flatbed-Printer-
fig-21

Alarm function

Item Alarm (ALM) Ion level (ION) Condition (COND)
Indication Indicator light blinks three times about every second.
Indicator light blinks twice about every second. Indicator light blinks. once

about every second


Status etc.

| ****

Internal circuit has been broken. Abnormal discharge occurs.

| Due to blot on the electrode probe and wear of it, ion production has decreased.

Use this as a guide for time to take care of the electrode probe.

| The installed environment (temperature, humidity, peripheral metals, etc.) have affected the performance to remove electricity.
Removing electricity| Removing electricity stops.| Removing electricity continues.| Removing electricity continues.


Countermeasure

| ****

Contact a distributor in your district or our office.

| Take care of the electrode probe.*1

If the status cannot be improved, replace the relevant electrode probe.

| ****

Check the environment and peripheral metals.

Replacement part| ****| SPA-0208

Tungsten electrode probes for ionizer (including 4)

| ****

Before taking care of the electrode probe, turn off the main power of the main body, and be careful to perform the work.

Angle adjustment of the ionizer

The ionizer can be adjusted in angle. If it is hard to access to the work at the back side of the table, move the ionizer on the upper side.Mimaki-UJF-
3042MKII-Desktop-Size-UV-LED-Flatbed-Printer-fig-22

D203082-20-15042022
© 2016 MIMAKI ENGINEERING CO., LTD. All rights reserved

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals