Midea U 1.0hp Window Type Inverter User Manual

June 5, 2024
Midea

Midea U 1.0hp Window Type Inverter User Manual

Midea U 1.0hp Window Type Inverter User Manual

IMPORTANT NOTE:

  • Before using your air conditioner, please read this manual carefully and keep it for future reference.

Important Safety Instructions

READ THIS MANUAL
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You’ll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all.
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications.

Midea U 1.0hp Window Type Inverter User Manual -
Warning

WARNING

  • Plug in power plug properly. Otherwise, it may cause electric shock or fire due to excess heat generation. Do not operate or stop the unit by inserting or pulling out the power plug. It may cause electric shock or fire due to heat generation. Do not damage or use an unspecified power cord. It may cause electric shock or fire. If the power cord is damaged, it must be replaced by the manufacturer or an authorised service centre or a similarly qualified person in order to avoid a hazard.
  • Always install circuit breaker and a dedicated power circuit. Incorrect installation may cause fire and electric shock. Do not operate with wet hands or in damp environment. It may cause electric shock Do not direct airflow at room occupants only. This could damage your health.
  • Always ensure effective grounding. Incorrect grounding may cause electric shock. Do not allow water to run into electric parts. It may cause failure of machine of electric shock. Do not modify power cord length or share the outlet with other appliances. It may cause electric shock or fire due to heat generation.
  • Unplug the unit if strange sounds, smell, or smoke comes from it. It may cause fire and electric shock. Do not use the socket if it is loose or damaged. It may cause fire and electric shock. Do not open the unit during operation. It may cause electric shock.
  • Keep firearms away. It may cause fire. Do not use the power cord close to heating appliances It may cause fire and electric shock. Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc. It may cause an explosion or fire.
  • Ventilate room before operating air conditioner if there is a gas leakage from another appliance. It may cause explosion, fire and, burns. Do not disassemble or modify unit. It may cause failure and electric shock.

CAUTION

  • When the air filter is to be removed, do not touch the metal parts of the unit. It may cause an injury. Do not put a pet or house plant where it will be exposed to direct air flow. This could injure the pet or plant. Ventilate the room well when used together with a stove, etc. An oxygen shortage may occur.
  • Do not use strong detergent such as wax or thinner but use a soft cloth. Appearance may be deteriorated due to change of product color or scratching of its surface. Do not clean the air conditioner with water. Water may enter the unit and degrade the insulation. It may cause an electric shock. Do not use for special purposes. Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects. It may cause deterioration of quality, etc.
  • Stop operation and close the window in storm or hurricane. Operation with windows opened may cause wetting of indoor and soaking of household furniture. When the unit is to be cleaned, switch off, and turn off the circuit breaker. Do not clean unit when power is on as it may cause fire and electric shock, it may cause an injury. Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure. If bracket is damaged, there is concern of damage due to falling of unit.
  • Always insert the filters securely. Clean filter once every two weeks. Operation without filters may cause failure. Hold the plug by the head of the power plug when taking it out. It may cause electric shock and damage. Turn off the main power switch when not using the unit for a long time. It may cause failure of product or fire.
  • Do not place obstacles around air-inlets or inside of air-outlet. It may cause failure of appliance or accident. Do not place heavy object on the power cord and ensure that the cord is not compressed. There is danger of fire or electric shock. Do not drink water drained from air conditioner. It contains contaminants and could make you sick.
  • Use caution when unpacking and installing. Sharp edges could cause injury.
  • If water enters the unit, turn the unit off at the power outlet and switch off the circuit breaker. Isolate supply by taking the power-plug out and contact a qualified service technician.

CAUTION

  • This appliance is not intended for use by persons (including children) with reduced physical , sensory or mental capabilities or lack of experience and knowledge, unless they have been givens prevision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • The appliance shall be installed in accordance with national wiring regulations.
  • Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
  • The appliance with electric heater shall have at least 1meter space to the combustible materials.
  • Contact the authorised service technician for repair or maintenance of this unit.
  • Contact the authorised installer for installation of this unit.

NOTE:
The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire. Please refer to the section Operation of Current Device for details. In the event that the power supply cord is damaged, it cannot be repaired-it must be replaced with acord from the Product Manufacturer.

WARNING
Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.

Grounding type wall receptacle

WARNING
For Your Safety Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Prevent Accidents To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following:

  • Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the the cabinet and behind the grille.
  • If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass first. If the window is a triple tricky pew it has careen panel included, remove the screen completely before installation.
  • Be sure the airconditionerh as been securely and correctly in stalled according to the installation instructions in this manual. Save this manual for possible future use in removing or installing this unit.
  • When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.

Electrical Information
The complete electrical rating of your new room air conditioner is stated on the serial plate. Refer to the rating when checking the electrical requirements.

  • Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
  • Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle. Ensure the receptacle is accessible after the unit installation.
  • Do not run air conditioner without side protective cover in place. This could result in mechanical damage within the air conditioner.
  • Do not use an extension cord or an adapter plug.

Operation of Current Device (Applicable to the unit adopts current detection device only )
The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord do the following:

  1. Plug in the Air Conditioner.
  2. The power supply cord will have TWO buttons on the plug head. Press the TEST button, you will notice a click as the RESET button pops out.
  3. Press the RESET button, again you will notice a click as the button engages.
  4. The power supply cord is now supplying electricity to the unit. (On some products this it also indicated by a light on the plug head.)

NOTE:

  • Do not use this device to turn the unit on or off.
  • Always make sure the RESET button is pushed in for correct operation.
  • The power supply must be replaced if it fails reset when either the TEST button is pushed, or it cannot be reset. A new one can be obtained from the product manufacturer.
  • If power supply cord is damaged, it cannot be repaired. It MUST be replaced by one obtained from the product manufacturer.
    NOTE: This air conditioner is designed to be operated under condition as follow s:

Midea U 1.0hp Window Type Inverter User Manual - Cooling
operation

Note: Performance may be reduced outside of these operating t emperatures.

WARNING: (for using R290/R32 refrigerant only)

-Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
-The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance) and ignition sources or (for example: an operating electric heater) close to the appliance. The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
-Do not pierce or burn.
-Be aware that the refrigerants may not contain an odour.
-Compliance with national gas regulations shall be observed.
-Keep ventilation openings clear of obstruction.
-The appliance shall be stored so as to prevent mechanical damage from occurring.
-A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
-Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorises their competence to handle refrigerants safely in accordance with an industry recognised assessment specification.
-Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
-DO NOT modify the length of the power cord or use an extension cord to power the unit. DO NOT share a single outlet with other electrical appliances. Improper power supply can cause fire or electrical shock.
-Please follow the instruction carefully to handle, install, clear, service the air conditioner to avoid any damage or hazard.
– Flammable Refrigerant R32 is used within air conditioner. When maintaining or disposing the air conditioner, the refrigerant (R32 or R290) shall be recovered properly, shall not discharge to air directly. -No any open fire or device like switch which may generate spark/arcing shall be around air conditioner to avoid causing ignition of the flammable refrigerant used. Please follow the instruction carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.
-Flammable refrigerant -R32 is used in air conditioner. Please follow the instruction carefully to avoid any hazard.

Caution: Risk of fire/ flammable materials (Required for R32/R290 units only)

IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.

Explanation of symbols displayed on the unit(For the unit adopts R32/ R290 Refrigerant only):

Midea U 1.0hp Window Type Inverter User Manual - Explanation of
symbols

WARNINGS (for using R290/R32 refrigerant only)

  1. Transport of equipment containing flammable refrigerants See transport regulations

  2. Marking of equipment using signs See local regulations

  3. Disposal of equipment using flammable refrigerants See national regulations.

  4. Storage of equipment/ appliances The storage of equipment should be in accordance with the manufacturer’s instructions.

  5. Storage of packed (unsold) equipment Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.

  6. Information on servicing

  7. Checks to the area
    Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.

  8. Work procedure Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed.

  9. General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.

  10. Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.

  11. Presence of fire extinguisher If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.

  12. No ignition sources No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. No Smoking signs shall be displayed.

  13. ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.

  14. Checks to the refrigeration equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: The charge size is in accordance with the room size within which the refrigerant containing parts are installed; The ventilation machinery and outlets are operating adequately and are not obstructed; If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant; Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected; Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.

  15. Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised. Initial safety checks shall include: That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking; That there no live electrical components and wiring are exposed while charging, recovering or purging the system; That there is continuity of earth bonding.

  16. Repairs to sealed components

  17. During repairs to sealed components, all electrical supplies shall be disconnected from the
    equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.

  18. Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc. Ensure that apparatus is mounted securely. WARNINGS (for using R290/R32 refrigerant only)
    Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications.
    NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them.

  19. Repair to intrinsically safe components Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.

  20. Cabling Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.

  21. Detection of flammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.

  22. Leak detection methods The following leak detection methods are deemed acceptable for systems containing flammable refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum) is confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/ extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.

  23. Removal and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used. However, it is important that best practice is followed since flammability is a consideration. Opening of the refrigeration systems shall not be done by brazing. The following procedure shall be adhered to: Remove refrigerant; Purge the circuit with inert gas; Evacuate; Purge again with inert gas; Open the circuit by cutting or brazing. The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be flushed with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task. Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipe-work are to take place. Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.

  24. Charging procedures In addition to conventional charging procedures, the following requirements shall be followed. Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them. Cylinders shall be kept upright. Ensure that the refrigeration system is earthed prior to charging the system with refrigerant. Label the system when charging is complete (if not already). Extreme care shall be taken not to overfill the refrigeration system. Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.

  25. Decommissioning Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.
    a)Become familiar with the equipment and its operation. b)Isolate system electrically.
    c)Before attempting the procedure ensure that: Mechanical handling equipment is available, if required, for handling refrigerant cylinders; All personal protective equipment is available and being used correctly; The recovery process is supervised at all times by a competent person; Recovery equipment and cylinders conform to the appropriate standards.
    d)Pump down refrigerant system, if possible.
    e)If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
    f)Make sure that cylinder is situated on the scales before recovery takes place.
    g)Start the recovery machine and operate in accordance with manufacturer’s instructions.
    h)Do not overfill cylinders. (No more than 80 % volume liquid charge).
    i)Do not exceed the maximum working pressure of the cylinder, even temporarily.
    j)When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off. k)Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.

  26. Labelling Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.

  27. Recovery When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.

Installation Instructions

NOTE: The unit you purchased may be look like the following:

BEFORE YOU BEGIN
Read these instructions completely and carefully. MPORTANT-Save these instructions for local inspector’s use. IMPORTANT-Observe all governing codes and ordnances.
Note to Installer- Be sure to leave these instructions with the Consumer. Note to Consumer- Keep these instructions for future reference. Skill level- Installation of this appliance requires basic mechanical skills. Completion time- Approximately 1 hour. We recommend that two people install this product. Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the Warranty. You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.

NOTE:
All the illustrations in this manual are for explanation purpose only. The air conditioner you have may be slightly different. The actual shape shall prevail.
Page 13

Additional Instruction for mounting the unit with the bracket.

Midea U 1.0hp Window Type Inverter User Manual - Additional Instruction for
mounting the unit with the bracket

WALL-MOUNTED INSTRUCTIONS
Note: Remove the air conditioner and hardware’s from the carton and place on a flat surface. Save Carton and these Installation Instructions for future reference. The carton is the best way to store unit during winter, or when not in use.

Suggested tools

  1.  Screw driver (medium size Phillips)
  2. Tape measure or ruler
  3. Knife or scissors
  4. Level gauge

Hardware(Packed with the unit)

Midea U 1.0hp Window Type Inverter User Manual -
Hardware

Select the best location

  1. To avoid vibration and noise, make sure the unit is installed securely and firmly.
  2. Install the unit where the sunlight does not shine directly on the unit. If the unit receives direct sunlight, build an awning to shade the cabinet.
  3. There should be no obstacle, such as a fence or wall, within 50cm from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling and heating efficiency of the air conditioner.
  4. Install the unit a little obliquely outward not to leak the condensed water into the room (about 3~4 With level).
  5. Install the unit with its bottom portion 75~150cm above the floor level.
  6. The power cord must be connected to an independent circuit. The yellow/green wire must be grounded.

CAUTION
All side louvers of the cabinet must remain exposed to the outside of the structure.
Note: After installing, make sure the air conditioner is tilted 3~4° to the outside to allow water drainage and perfect cooling efficiency.

Select the best location
Note: Unit may be supported by a solid frame from below or by a hanger from a solid overhead support.

Installations of the unit into the wall

Midea U 1.0hp Window Type Inverter User Manual - Installations of the unit
into the wall

Normal Sounds

Midea U 1.0hp Window Type Inverter User Manual - Normal
Sounds

NOTE:
All the illustrations in this manual are for explanation purpose only. The air conditioner you have may be slightly different. The actual shape shall prevail.

Air Conditioner Features

WARNING
To reduce the risk of fire, electric shock, or injury to persons, read the IMPORTANT SAFETY INSTRUCTIONS before operating this appliance.

CAUTION
Please always wait 3 minutes when turning unit off then on again, and when changing from cool to fan and back to cool. This prevents compressor from overheating & possible circuit breaker tripping.

To begin operating the air conditioner, follow these steps:

  1. Set the thermostat to the highest number (coldest or cooler setting).
  2. Set the selector control to the highest COOL setting.
  3. Adjust the louver for comfortable air flow (see Air Directional Louvers).
  4. Once the room has cooled, adjust the
    thermostat to the setting you find most comfortable. 5. Make sure that the air flow inside and outside are not obstructed by anything.

Air Directional Louvers Lever
Midea U 1.0hp Window Type Inverter User Manual - Air Directional
Louvers
The louvers will allow you to direct the airflow Up or Down(on some models) and Left or Right throughout the room as needed. Pivot horizontal louvers until the desired Up/Down direction is obtained. Move the Lever(s) from side to side until the desired Left/Right direction is obtained.

ELECTRONIC CONTROL OPERATING INSTRUCTIONS
NOTE:
Different models have different control buttons and indicator lights. Not all the control buttons and indicator lights describing below are available for the unit you purchased. Please check the control panel of the unit you purchased.

The unit can be controlled by the unit control alone or with the remote.

Midea U 1.0hp Window Type Inverter User Manual - ELECTRONIC CONTROL
OPERATING INSTRUCTIONS

Operation buttons

  1. ON/OFF : Press ON/OFF button to turn unit on or off. NOTE: The unit will initiate automatically the Energy Saver function under Cool, Dry and Auto modes.

  2. CONNECT button: For the first time to use WLAN function, press the button for 3 seconds to initiate the WLAN connection mode. The LED DISPLAY shows ‘AP’ to indicate you can set WLAN connection. If connection(router) is successful within 8 minutes, the unit will exit WLAN connection mode automatically and the CONNECT indicator illuminates. If connection is failure within 8 minutes, the unit exits WLAN connection mode automatically. After WLAN connection is successful, you can press and hold CONNECT and DOWN ( ) buttons at the same time for 3 seconds to turn off WLAN function and the LED DISPLAY shows ‘OF’ for 3 seconds, press CONNECT and UP( ) buttons at the same time to
    turn on WLAN function and the LED DISPLAY shows ‘On’ for 3 seconds.

  3.  TIMER button
    • Press Timer button, the TIMER ON or TIMER OFF indicator light illuminates. it indicates the Auto Start or Auto Stop program is initiated. For some units, keep pressing the Timer button will cancel the timer settings.
    • Press or hold the UP or DOWN button to change the Auto time by 0.5 hour increments, up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining until start.
    • The selected time will register in 5 seconds, and the system will automatically revert back to display the previous temperature setting or room temperature when the unit is on.(when the unit is off, there is no display.)
    • Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Auto Start/Stop timed program.

  4. ECO button Press ECO button to initiate this function. This function is available on COOL, DRY, AUTO (only AUTOCOOLING and AUTO-FAN) modes. The fan will continue to run for 3 minutes after the compressor shuts off. The fan then cycles on for 2 minutes at 10 minute intervals until the room temperature is above the set temperature, at which time the compressor turns back on and Cooling Starts.

  5. MODE button To choose operating mode, press Mode button. Each time you press the button, a mode is selected in a sequence that goes from Auto, Cool, Dry and Fan. The indicator light beside will be illuminated and remained on once the mode is selected. The unit will initiate automatically the Energy Saver function under Cool, Dry, Auto(only Auto-Cooling and Auto-Fan)modes.
    1.To operate on Auto feature:
    • When you set the air conditioner in AUTO mode, it will automatically select cooling, or fan only operation depending on what temperature you have selected and the room temperature.
    •  The air conditioner will control room temperature automatically round the temperature point set by you.
    • In this mode, the fan speed cannot be adjusted, it starts automatically at a speed according to the room temperature.
    To operate on COOL mode:
    •  Choose Cool Mode to set the cooling function. Use the Up and Down buttons to choose the desired temperature. When Cool Mode is selected, the fan speed can be adjusted by pressing the fan button.
    To operate on Dry mode:
    • In this mode, the air conditioner will generally operate in the form of a dehumidifier. Since the conditioned space is a closed or sealed area, some degree of cooling will continue. On Dry mode, the automatic wind is not adjustable. 4. To operate on Fan Only:
    • Use this function only when cooling is not desired, such as for room air circulation or to exhaust stale air(on some models). (Remember to open the vent during this function, but keep it closed during cooling for maximum cooling efficiency.) You can choose any fan speed you prefer.
    • In Fan only mode ,the temperature is not adjusted.

  6.  button Press ” “or” ” button to change temperature setting.
    NOTE: Press or hold either ” “or” “button until the desired temperature is shown on the display. This temperature will be automatically maintained anywhere between 60(16) and 86(30). If you want the display to read the actual room temperature, see “To Operate on Fan Only “section.

  7. FAN button Press Fan button to select the Fan Speed in four steps-Auto, Low, Med or High. Each time the button is pressed, the fan speed mode is shifted. For some models, the fan speed can not be adjusted.

  8. SLEEP button Press Sleep button to initiate the sleep mode. In this mode the selected temperature will increase (cooling) by 2/1 (or 2) 30 minutes after the mode is selected. The temperature will then increase (cooling) by another 2/1 (or 2) after an additional 30 minutes. This new temperature will be maintained for 7 hours before it returns to the originally selected temperature. This ends the Sleep mode and the unit will continue to operate as originally programmed. The Sleep mode program can be cancelled at any time during operation by pressing the Sleep button again.

  9. SWING button Used to initiate the Auto swing feature. When the operation is ON, press the SWING button can stop the louver at the desired angle. Press SWING button for 3 seconds to initiate the filter feature. This feature is a reminder to clean the Air Filter for more efficient operation. The LED(the light above the button) will illuminate after 250 hours of operation.

DISPLAYS

DIS P L AYS :
DISPLAYS: Shows the set temperature in ” ” or ” ” and the Auto-timer settings. While on Fan only mode, it shows the room temperature. If the room temperature is too high or low, it will display ” HI” or ” LO”.

Error codes:
The unit may stop operation or continue to run safely. If the error codes appear, wait for about 10 minutes. The problem may resolve itself. If not, disconnect the power, then connect it again. Turn the unit on. If the problem persists, disconnect the power and contact your nearest customer service center. Error code appears and begins with the letters as the following in the window display of indoor unit: EH(xx), EL(xx), EC(xx) , PH(xx), PL(xx), PC(xx)

NOTE: If your problem persists after performing the checks and diagnostics above, turn off your unit immediately and contact an authorized service center.

NOTE:
If the unit breaks off unexpectedly due to the power cut, it will restart with the previous function setting automatically when the power resumes.

ADDITIONAL THINGS YOU SHOULD KNOW
Now that you have mastered the operating procedure, here are more features in your control that you should become familiar with.

  • The Cool circuit has an automatic 3 minutes time delayed start if the unit is turned off and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping. The fan will continue to run during this time.
  • The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius. To convert from one to the other, press and hold the Up and Down buttons at the same time for 3 seconds.

Care and Cleaning

CAUTION
Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards.

Air Filter Cleaning

The air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils.

  • Push the vent handle to the Vent Closed position (where applicable). Open the front panel.
  • Take the filter by the center and pull up and out.
  • Wash the filter using liquid dishwashing detergent and warm water. Rinse filter thoroughly. Gently shake excess water from the filter. Be sure the filter is thoroughly dry before replacing. Instead of washing, you may vacuum the filter clean.

Note: Never use hot water over 40°C(104°F) to clean the air filter. Never attempt to operate the unit without the air filter.

Cabinet Cleaning
Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry. Never use harsh cleaners, wax or polish on the cabinet front. Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the air conditioner. Plug in air conditioner.

Winter Storage
If you plan to store the air conditioner during the winter, remove it carefully from the window according to the installation instructions. Cover it with plastic or return it to the original carton.

TROUBLESHOOTING TIPS

Before calling for service, review this list. It may save your time and expense. This list includes common occurrences that are not the result of defective workman-ship or materials in this appliance.

Midea U 1.0hp Window Type Inverter User Manual - TROUBLESHOOTING
TIPS Midea U 1.0hp Window
Type Inverter User Manual - TROUBLESHOOTING TIPS Midea U 1.0hp Window Type Inverter User Manual -
TROUBLESHOOTING TIPS

The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to the service website, please check for the latest version.
CW008UI-QB

REMOTE CONTROLLER
OWNER’S MANUAL
IMPORTANT NOTE: Thank you for purchasing our air conditioner. Please read this manual carefully before operating your new air conditioning unit. Make sure to save this manual for future reference.

Remote Controller Specifications

Midea U 1.0hp Window Type Inverter User Manual - Remote Controller
Specifications

Quick Start Guide

Midea U 1.0hp Window Type Inverter User Manual - Quick Start
Guide

NOT SURE WHAT A FUNCTION DOES?
Refer to the How to Use Basic Functions and How to Use Advanced Functions sections of this manual for a detailed description of how to use your air conditioner.

SPECIAL NOTE

  • Button designs on your unit may differ slightly from the example shown.
  • If the indoor unit does not have a particular function, pressing that function’s button on the remote control will have no effect.
  • When there are wide differences between “Remote controller Manual” and “USER’S MANUAL” on function description, the description of “USER’S MANUAL” shall prevail.

Handling the Remote Controller

Inserting and Replacing Batteries
Your air conditioning unit may come with two batteries(some units). Put the batteries in the remote control before use.

  1. Slide the back cover from the remote control downward, exposing the battery compartment.
  2. Insert the batteries, paying attention to match up the (+) and (-) ends of the batteries with the symbols inside the battery compartment.
  3. Slide the battery cover back into place.

BATTERY NOTES
For optimum product performance:

  • Do not mix old and new batteries, or batteries of different types.
  • Do not leave batteries in the remote control if you don’t plan on using the device for more than 2 months.

BATTERY DISPOSAL
Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal of batteries.

TIPS FOR USING REMOTE CONTROL

  • The remote control must be used within 8 meters of the unit.
  • The unit will beep when remote signal is received.
  • Curtains, other materials and direct sunlight can interfere with the infrared signal receiver.
  • Remove batteries if the remote will not be used more than 2 months.

CAUTIONS FOR USING REMOTE CONTROL
The device could comply with the local national regulations.

  • In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
  • In USA, this device complies with part 15 of the

FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
  • Changes or modifications not expressly approved by the party responsible for compliance could void user’s authority to operate the equipment.

Buttons and Functions

Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the How to Use Basic Functions section of this manual.

Midea U 1.0hp Window Type Inverter User Manual - Buttons and
Functions Midea U 1.0hp
Window Type Inverter User Manual - Buttons and Functions ![Midea U 1.0hp Window Type Inverter User Manual

  • Buttons and Functions](https://manuals.plus/wp- content/uploads/2022/06/Midea-U-1.0hp-Window-Type-Inverter-User-Manual- Buttons-and-Functions-3.jpg) ![Midea U 1.0hp Window Type Inverter User Manual
  • Buttons and Functions](https://manuals.plus/wp- content/uploads/2022/06/Midea-U-1.0hp-Window-Type-Inverter-User-Manual- Buttons-and-Functions-4.jpg)

Midea U 1.0hp Window Type Inverter User Manual - Model
M

TEMP ▼ : Decreases temperate in 1°F/1°C increments. Min. temperature is 60°F(16°C).
TEMP ▲ : Increases temperate in 1°F/1°C increments. Max. temperature is 86°F(30°C). NOTE: Press and hold TEMP and buttons at the same time for 3 seconds to switch °C to °F.

FAN SPEED: Selects fan speeds in the following order: AUTO LOW (MED) HIGH
NOTE: For some models, the MED fan speed can not be selected.(RG51H2(2)/EFU1-M, R51H3(2)/EU1-M)

MODE: Scrolls through operation modes as follows: (AUTO) COOL (DRY) (HEAT) FAN NOTE: Please do not select HEAT mode if the machine you purchased is cooling only type. Heat mode is not supported by the cooling only appliance. For model F (RG51G(2)/CEFU1) , the AUTO mode can not be selected. For model I(RG51G5(2)/EU1) , the AUTO and DRY mode can not be selected.
SLEEP: Saves energy during sleeping hours .
SHORT CUT: Sets and activates your favorite pre-settings.

TIMER ON: Sets timer to turn unit on (see How to Use Basic Functions for instructions). I SENSE: Temperature sensing and room temperature display button. TIMER OFF: Sets timer to turn unit off (see How to Use Basic Functions for instructions). LED DISPLAY: Press this button to turn on and turn off the display on the indoor unit.
: Press this button to alternate the temperature display between the °C & °F.
SWING: Starts and stops the horizontal louver movement. Hold down for 2 seconds to initiate vertical louver auto swing feature(some units) .
FRESH: The ion generators energized and will help to purify the air inside ENERGY SAVER: Press Energy saver button to initiate this function. This function is available on COOL, DRY, AUTO (only AUTO-COOLING and AUTO-FAN) modes. The fan will continue to run for 3 minutes after the compressor shuts off. The fan then cycles on for 2 minutes at 10 minute intervals until the room temperature is above the set temperature, at which time the compressor turns back on and Cooling Starts.
NOTE: Press together the two buttons simultaneously for 5 seconds to lock the keyboard. Press together the two buttons for 2 seconds to unlock the keyboard.

Remote Screen Indicators

Information are displayed when the remote controller is power up.

Note: All indicators shown in the figure are for the purpose of clear presentation. But during the actaul operation, only the relative function signs are shown on the display window.

How to Use Basic Functions

ATTENTION Before operation, please ensure the unit is plugged in and power is available.

AUTO Mode

NOTE:

  1. In AUTO mode, the unit will automatically select the COOL, FAN, or HEAT function based on the set temperature.
  2. In AUTO mode, fan speed can not be set.

COOL or HEAT

DRY Mode

Midea U 1.0hp Window Type Inverter User Manual - DRY
Mode

NOTE: In DRY mode, fan speed can not be set since it has already been automatically controlled.

FAN Mode

Midea U 1.0hp Window Type Inverter User Manual - FAN
Mode

NOTE: In FAN mode, you can’t set the temperature. As a result , no temperature displays in remote screen.

Setting the TIMER

TIMER ON/OFF – Set the amount of time after which the unit will automatically turn on/off.

TIMER ON setting
Midea U 1.0hp Window Type Inverter User Manual - TIMER ON
setting

TIMER OFF setting

Midea U 1.0hp Window Type Inverter User Manual - TIMER OFF
setting

NOTE:

  1. When setting the TIMER ON or TIMER OFF, the time will increase by 30 minutes increments with each
    press, up to 10 hours. After 10 hours and up to 24, it will increase in 1 hour increments. (For example, press 5 times to get 2.5h, and press 10 times to get 5h,) The timer will revert to 0.0 after 24.

  2. Cancel either function by setting its timer to 0.0h.

TIMER ON & OFF setting(example)
Keep in mind that the time periods you set for both functions refer to hours after the current time.

Midea U 1.0hp Window Type Inverter User Manual - TIMER ON & OFF
setting

How to Use Advanced Functions

Swing function(some units)
Press Swing button
Midea U 1.0hp Window Type Inverter User Manual - Swing
function

SLEEP function

The SLEEP function is used to decrease energy use while you sleep (and don t need the same temperature settings to stay comfortable). This function can only be activated via remote control. The sleep function is not available in Fan or Dry mode. Please refer to the OWNER’S MANUAL for more details.

I SENSE function (some units)

When the I SENSE function is activated, the remote display is actual temperature at its location. The remote control will send this signal to the air conditioner every 3 minutes interval until press the I SENSE button again.

NOTE: Press this button for seven seconds to start/stop memory feature of I SENSE function.

  • If the memory feature is activated, ” On ” displays for 3 seconds on the screen.
  • If the memory feature is stopped, ” OF ” displays for 3 seconds on the screen.
  • While the memory feature is activated, press the ON/OFF button, shift the mode or power failure will not cancel the I SENSE function.

SHORTCUT function(some units)

Used to restore the current settings or resume previous settings.

Push this button when remote controller is on, the system will automatically revert back to the previous settings including operating mode, setting temperature, fan speed level and sleep feature(if activated). If pushing more than 2 seconds, the system will automatically restore the current operation settings including operating mode, setting temperature, fan speed level and sleep feature (if activated ).

FP function(some units)

Midea U 1.0hp Window Type Inverter User Manual - FP
function Note: This function is for heat pump air conditioner only. Press this button 2 times during one second under HEAT Mode and setting temperature of 16 C/60 F to activate FP function. Press On/Off, Sleep, Mode, Fan and Temp. button while operating will cancel this function.

The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.
CR278-RG51(F-H-G)(2)

Customer Care
Email: customercare@midea.com.
ph Toll free: 1-800-10-863-5522
Landline: (02) 8863-55-22 SMS: 0917-8425555

For more information, please visit our website www.midea.com.ph

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals