Gude GP 1100.1 Automatic Garden Water Pump Instructions
- June 5, 2024
- Gude
Table of Contents
Translation of the original instructions
Pump series
GP 1100.1
93905| HWA 1100.1 VF
93907| HWW 1100.1 VF
93906
HWW 1400.2 VF
93908
HWW 1400.3 VF INOX
93909
---|---|---
GÜDE GmbH & Co. KG
74549 Wolpertshausen
Please read the instructions carefully before starting the machine.
GP 1100.1
93905| HWA 1100.1 VF
93907| HWW 1100.1 VF
93906
HWW 1400.2 VF
93908
HWW 1400.3 VF INOX
93909
starting-up the device|
---|---
Operation|
Wartung & Reinigung Maintenance & Cleaning|
Transport & Lagerung
Transport & Storage|
EC Declaration of Conformity|
GP 1100.1
HWA 1100.1 VF
HWW 1400.2 VF
HWW 1400.3 VF INOX
HWW 1100.1 VF
GP 1100.1
HWA 1100.1 VF
HWW 1400.2 VF
HWW 1400.3 VF INOX
HWW 1100.1 VF
Suction hose with check valve
- teflon sealing tape
|
---|---
GP 1100.1 HWA 1100.1 VF
HWW 1400.2 VF
HWW 1400.3 VF INOX
HWW 1100.1 V
GP 1100.1
HWA 1100.1 VF
HWW 1400.2 VF
HWW 1400.3 VF INOX
HWW 1100.1 VF
| |
---|---|---
| |
In “Ever on mode” and “Time mode” neither the dry run
protection nor the automatic switch-off function is active!
| |
---|---|---
| |
Technical Data
Garden pump | GP 1100.1 |
---|---|
Art. No | 93905 |
Rated voltage | 220 – 240 V |
Frequency | 50 Hz |
Motor power P1 | 1100 W |
Insulation class | F |
Degree of protection | IP X4 |
Q m a x Max. delivered quantity | 4.600 l/h |
H min min. Head height | 2 m |
H m a x Max. head of delivery | 46 m |
Max. suction head | 8 m |
Max. Water temperature | 35 °C |
Service connection | IG 1 “ |
Dry run protection | No |
Net/gross weight | 11,1 / 12,8 kg |
Dimensions L x W x H | 470 x 215 x 300 mm |
Domestic water supply system | HWA 1100.1 VF |
--- | --- |
Art. No | 93907 |
Rated voltage | 220 – 240 V |
Frequency | 50 Hz |
Motor power P1 | 1100 W |
Insulation class | F |
Degree of protection | IP X4 |
Q m a x Max. delivered quantity | 4.600 l/h |
H min min. Head height | 2 m |
H m a x Max. head of delivery | 46 m |
Max. suction head | 8 m |
Max. Water temperature | 35 °C |
Service connection | IG 1 “ |
Dry run protection | Yes |
Net/gross weight | 11,2 kg / 12,9 kg |
Dimensions L x W x H | 470 x 215 x 300 mm |
Domestic water supply unit | HWW 1100.1 VF |
HWW 1400.3 VF INOX
---|---|---|---
Art. No| 93906| 93908| 93909
Rated voltage| 220 – 240 V| 220 – 240 V| 220 – 240 V
Frequency| 50 – 60 Hz| 50 Hz| 50 Hz
Motor power P1| 1100 W| 1400 W| 1400 W
Insulation class| F| F| F
Degree of protection| IP X4| IP X4| IP X4
Q m a x Max. delivered quantity| 4.600 l/h| 4.800 l/h| 4.800
l/h
H min min. Head height| 2 m| 2 m| 2 m
H m a x Max. head of delivery| 46 m| 48 m| 48 m
Max. suction head| 8 m| 8 m| 8 m
Max. Water temperature| 35 °C| 35 °C| 35 °C
Service connection| IG 1 “| IG 1 “| IG 1 “
Tank capacity| 24 l| 24 l| 24 l
Dry run protection| No| Yes
Yes
Net/gross weight| 15,8 kg / 18,5 kg| 15,9 kg / 18,6 kg| 15,9 kg / 18,6 kg
Dimensions L x W x H| 500 x 265 x 600 mm|
500 x 265 x 600 mm
| 500 x 265 x 600 mm
Read and understand the operating instructions before using the appliance. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties. In case of any doubts about connection and operation refer please to our customer center
Specified Conditions of Use
The pump is designed for pumping clean water only to supply the home with
water and to use it at home, in garden, courtyard and for fields. Respecting
technical data and safety precautions.
Do not use this product in any other way as stated for normal use. Not
observing general regulations in force and instructions from this manual does
not make the manufacturer liable for damages.
The pump is not suitable for long-term operation (e.g. as a circulating pump
in ponds or for brooks). If this type of operation is carried out, the service
life will be reduced accordingly.
Do not leave the pump unattended while in operation in order to prevent
subsequent damages caused by eventual malfunctions. Make sure to disconnect
the device from the grid if you do not plan on using it.
Do not use the pump for drinking water!
The pump must not be connected to the existing water-supply network as a
pressure-boosting device.
Never use the pump as a pool circulation pump.
Safety Warnings
WARNING! Electric shock! There is a risk of an injury caused by electric
shock! This appliance is not intended for use by persons (including children)
with limited physical, sensory or mental capabilities or insufficient
experience and/or knowledge unless they are supervised by a person who is
responsible for their safety or have been instructed by them in the safe use
of the appliance. Children should be supervised in order to ensure that they
do not play with the tool. Always keep children and unauthorised persons out
of reach of the appliance.
Operation is only allowed with a safety switch against stray current (RCD max.
stray current of 30mA).
Before putting into operation, a qualified electrician must check whether
electric safety measures required are in place. Any national regulations in
this regard must be complied with. Electric connection to a socket. Do not
expose tools to rain. Do not use tools in damp or wet locations. It is
necessary to make sure the connecting socket was not near water and humidity
and the plug was protected against humidity. Avoid installing the appliance in
wet shafts (risk of short circuit, corrosion effects)! Check the voltage.
Technical data given on the type label must correspond with electric network
voltage. Only use splash proof extension cables approved for outdoor purposes.
Do not grab the feeder cable, plunge the pump, lift or carry it while it is
connected to the grid! Check the cable and/or socket for damages before the
appliance putting into operation. To avoid danger, a damaged mains supply pipe
must be replaced by the manufacturer. Do not under any circumstances attempt
any repair yourself. Protect the feeder cable from excessive temperatures, oil
and sharp edges.
If the pump is in operation, neither people nor animals can be present or
plunged in the pumped liquid (e.g. pools, cellars, etc.).
The pump must not in any case run without fillings Do not leave the pump
unattended while in operation in order to prevent subsequent damages caused by
eventual malfunctions. Make sure to disconnect the device from the grid if you
do not plan on using it. The temperature of the drained liquid must not exceed
+35 °C. When using the pump for domestic water supply, always observe the
local regulations of water management authorities and the waste water
drainage. If the pump is used in ponds, wells, etc. and appropriate pumping
stations, standards valid for pumps in the given country must unconditionally
be observed. Do not use pump at outside temperatures over 40 °C or under 0 °C
In cold weather, the pumping body motor should not be wrapped in a blanket or
another piece of textile with intent to prevent the water freezing. The user
is responsible to third parties if pump (dumping stations, etc.) is used.
Water escapes between the motor and pump, mechanical seal leaks (approx. 35
drops of water per day is considered insignificant, this leakage is functional
with a mechanical seal).
Requirements for operating staff
The operating staff must carefully read the Operating Instructions before
using the appliance.
Qualification: Apart from the detailed instructions by a professional, no
special qualification is necessary for appliance using.
Minimum age: Persons over 16 years of age can only work on the appliance. An
exception includes youngsters trained in order to reach knowledge under
supervision of the trainer during occupational education.
Training: Using the appliance only requires corresponding training by a
professional or the Operating Instructions. No special training is necessary.
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. For the sake of eventual accident, in accordance with DIN 13164, a workplace has to be fitted with a first-aid kit. It is essential to replace any used material in the first-aid kit immediately after it has been used. If you seek help, state the following pieces of information
- Accident site
- Accident type
- Number of injured persons
- Injury type(s)
Maintenance
Before any adjustment, cleaning and maintenance work, switch off the device
and disconnect it from the power supply. Prior to every use, visually check
the machine to rule out any defects, in particular on the power cable and the
plug. The appliance must not be used if damaged or safety equipment is
defective. Replace any worn-out and damaged parts.
Repairs and works specified in these Instructions may only be performed by
qualified authorized staff. Use only original accessories and original spare
parts. Caution! Depending on the design, water that is left standing for a
longer period of time may cause corrosion in the pump housing! (Brown
coloration) For winter storage, ensure that there is no water in the device.
Otherwise, frost exposure may cause irreparable damage to the device. The pump
must be stored in a completely empty and frost-proof state. You can reduce the
chance of the mechanical seals sticking by flushing out the pump with suitable
oil (e.g. vegetable oil). Only a regularly maintained and treated appliance
can serve as a satisfactory aid. Insufficient maintenance and care can lead to
unforeseen accidents and injuries.
Guarantee
The warranty period of 12 months applies to commercial use and 24 months applies to private use and commences on the day of purchase of the device. The guarantee solely covers inadequacies caused by a material defect or manufacturing defects. An original payment voucher with the date of the sale needs to be submitted for any claim in the guarantee period. The guarantee does not cover any unauthorized use such as appliance overloading, use of violence, damage as a result of any unauthorized interference or caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee. GÜDE cannot be held responsible for damages incurred in a consequence of unqualified installation or unskilled handling of the pump. The device has to be checked on a regular basis to ensure perfect functioning. Let us refer to the fact we do not assume any responsibility – according to standards in force – for damage eventually caused by our appliances in the below-mentioned cases: Unprofessional repairs executed by unauthorized service centres; Use in conflict with the designed purpose, or failure to observe the use as designed; Pump overload with a continuous run; Damage as a result of icing or any other fault caused by climatic influences; Identical regulations apply for accessory parts. To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the owner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).
Service
Do you have any technical questions?
Any claim? Do you need any spare parts or operating instructions?
We will quickly help you and without needles bureaucracy at our web pages at
www.guede.com in the Servicing part. Please help us be
able to help you. In order to identify your device in case of claim, we need
the serial No., product No. and year of production. All this data can be found
on the type label.
Serial No.:………
Art. No:……………….
Year of production:……….
SYMBOLS
| Read the operating instructions to reduce the risk of injury.
---|---
| Machine to be always unplugged before any adjustment and servicing work on
it.
| Insert the mains plug
| Staying in the transportation medium prohibited
| Warning against dangerous voltage
| Warning about automatic start-up
| Any damaged or disposed electric or electronic devices must be delivered to
appropriate collection centres.
| CE marking
| TÜV / GS conformity mark
Inspection and maintenance plan
Time interval | Description | Any other details |
---|---|---|
As needed | Clean the check valve and the prefilter. | Check the check valve |
function.
As required| Check pressure pipe and intake pipe for leakage and seal if
necessary| Check for any leaks
As required| Check and correct tank pressure| See page 16; Tank pressure 1,5 –
1,8 Bar
Failure removal
Failures | Causes | Removal |
---|---|---|
Engine does not start | No power supply. | |
Blocked pump wheel | Removal |
Turn the engine shaft with screwdriver through the fan
cover (to release friction circles sealing that may be stuck together).
Pump does not suck| Missing, loose or blocked check valve
Check valve is not in water.
No water in the pump shell.
Too high suction head.
Air bubbles in the suction pipeline.
Connections not sealed, pump sucks air,
pump is not deaerated.
Prefilter clogged| Fix or clean the check valve.
Immerse the check valve into water.
Fill the pump shell with water.
Check the suction head.
Check the tighten of suction pipeline.
Carefully repeat connection according to
the chapter „Connection“!
Clean the prefilter. 17
Thermal detector switching the pump off 4| The pump is overheated and switched
off by the thermal overloading protection.
No electric power supply.
Impurity particles (e.g. pebbles) have
settled down in the suction hole.| Let the device get cool! Check power
supply.
Disassemble and clean the suction hose, preventing from the suction of foreign
substances.
Insufficient amount of
water pumped| Too high suction head.
Strainer of the check valve dirty
Water level quickly drops down| Check the suction head.
Clean the strainer., Position the check valve
lower. Check water level
Reduced switching intervals| Air pressure in the receiver too low| Control air
pressure. 16
Water is coming out of the tank valve| Membrane defective| Replace/repair
(specialist workshop)
Translation of the EC-Declaration of Conformity
We, hereby declare the conception and construction of the below mentioned
appliances correspond – at the type of construction being launched – to
appropriate basic safety and hygienic requirements of EC Directives. In case
of any change to the appliance not discussed with us the Declaration expires.
Garden pump
93905 GP 1100.1
Appropriate EU Directives
| 2014/35/EU| | 2014/30/EU
---|---|---|---
| 1935/2004/EC| | 1907/2006/EC
| 2011/65/EU&2015/863/EU| | 2016/426/EU
| 2016/425/EU PPE| | 2014/29/EU
| 2006/42/EC| | 2015/1188/EU
Annex IV
Notified Body Name:………..
Adress:……………………
No:………………………….
Type Ex. Cert.-No.:………………….
2016/1628/EU
Emission No.:……………..
2000/14/EC_2005/88/EC
Method of compliance assessment
Annex VI
Wolpertshausen,
27.08.2020
Harmonised standards used
60335-2-41:2003/A2:2010
60335-1:2012/A2:2019
62233:2008 AfPS GS 2019:01 PAK
55014-1:2017
55014-2:2015
IEC 61000-3-2:2019
61000-3-3:2013/A1:2019
60335-2-41:2003+A1+A2
60335-1:2012+A11+A13+A1+A14+A2
62233:2008 AfPS GS 2019:01 PAK
55014-1:2017
55014-2:2015
IEC 61000-3-2:2019
61000-3-3:2013+A1
Guaranteed sound power level
LWA dB (A) 81 78,9
Managing Director
Authorized to compile the technical file
Domestic water supply system
GÜDE GmbH & Co. KG
Birkichstrasse 6
74549 Wolpertshausen
Deutschland
Tel.: +49-(0)7904/700-0
Fax.: +49-(0)7904/700-250
eMail: info@guede.com
93905, 93906, 93907, 93908, 93909 2020-10-27
Read User Manual Online (PDF format)