Gude 94246 GDT 901 Clean Water Pump Instruction Manual
- June 5, 2024
- Gude
Table of Contents
- Gude 94246 GDT 901 Clean Water Pump
- HOW TO USE
- SeRVice cOnnecTiOn
- STaRTinG-UP The Machine
- aUTOMaTic OPeRaTiOn / nOn-STOP OPeRaTiOn
- nOn-STOP OPeRaTiOn
- TRanSPORT / STORaGe
- Technical Data
- specified Conditions of Use
- safety instructions
- requirements for operating staff
- emergency procedure
- Maintenance
- guarantee
- service
- symbols
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Gude 94246 GDT 901 Clean Water Pump
HOW TO USE
- SeRVice connection
- STaRTinG-UP The Machine
- enGine PROTecTiOn
- aUTOMaTic OPeRaTiOn / nOn-STOP OPeRaTiOn
- TRanSPORT / STORaGe
SeRVice cOnnecTiOn
STaRTinG-UP The Machine
aUTOMaTic OPeRaTiOn / nOn-STOP OPeRaTiOn
nOn-STOP OPeRaTiOn
TRanSPORT / STORaGe
Technical Data
- art. no ………………………………………………….94601 …………………94602 ………………… 94603 ……………….. 94604 …………………94246
- Service connection …………230V/ 50hz ………. 230V/ 50hz ………..230V/ 50hz ……….230V/ 50hz ……….230V/ 50hz
- Motor output P1 ……………………….400 W …………………750 W ………………… 750 W ………………1100 W …………………800 W
- Max. immersion …………………………….4 m ……………………..7 m ……………………..7 m …………………….7 m ……………………..7 m
- Max. head of delivery …………………..5 m ……………………..8 m …………………….. 8 m ……………………. 8 m …………………..30 m
- Max. delivered quantity ……….8000 l/h ……………13000 l/h ……………13000 l/h …………..19000 l/h ……………..5500 l/h
- Max. suction …………………………….35 mm ………………. 35 mm ………………..35 mm ……………….35 mm ………………0,5 mm
- Max. Water temperature …………….35°c ……………………35°c …………………… 35°c ……………………35°c ……………………35°c
- hose connection ………………….1“-1½“ aG ………….1“-1½“ aG ………….1“-1½“ aG ………… 1“-1½“ aG ……………….. 1¼“AG
- Degree of protection …………………. iPX8 …………………… iPX8 …………………….iPX8 ……………………iPX8 …………………… iPX8
- Weight ……………………………………….. 4,4 kg ………………… 5,6 kg ………………….5,8 kg …………………7,4 kg ………………… 7,5 kg
Read and understand the operating instructions before using the appliance. abide by all the safetymeasures stated in the service manual. act responsibly toward third parties. in case of any doubts about connection and operation refer please to our customer center
specified Conditions of Use
The pump is solely used for drainage and for pumping into and out of containers in the house, garden, farm and agriculture and only for water. Respecting technical data and safety precautions. Do not use this product in any other way as stated for normal use. not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages.
- The pump is not suited for long-run operation (e.g. as a circulation pump in ponds or streams). When used in this manner, its service life is curtailed correspondingly. in these cases, then, use a time switch to secure sufficient idle periods between cycles of operation.
- Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
- Do not use the pump for drinking water!
- The pump must not be connected to the existing water-supply network as a pressureboosting device.
safety instructions
WArning!
electric shock! There is a risk of an injury caused by electric shock!
This device is not intended for use by persons (including children) with limited physical, sensory or mental capabilities or without the necessary lack experience or knowledge unless they are supervised by a person who is responsible for their safety or were instructed by that person in how to use the device. children should be supervised to ensure that they do not play with the device. always keep children and unauthorised persons out of reach of the appliance. Operation is only allowed with a safety switch against stray current (RcD max. stray current of 30ma). before putting into operation, a qualified electrician must check whether electric safety measures required are in place. any national regulations in this regar must be complied with. electric connection to a socket. it is necessary to make sure the connecting socket was not near water and humidity and the plug was protected against humidity. check the voltage. Technical data given on the type label must correspond with electric network voltage. Only use splash proof extension cables approved for outdoor purposes.
Do not grab the feeder cable, plunge the pump, lift or carry it while it is connected to the grid! check the cable and/or socket for damages before the appliance putting into operation. To avoid danger, a damaged mains supply pipe must be replaced by the manufacturer. Do not under any circumstances attempt any repair yourself. Protect the feeder cable from excessive temperatures, oil and sharp edges. Unplug the device prior to submersion, upon termination of operation, in the course of defect removal and prior to performing maintenance procedures. if the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.). The pump must not in any case run without fillings. Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it. The temperature of the drained liquid must not exceed +35 °c. if the lubricant escapes the fluid could become contaminated. if the pump is used in ponds, wells, etc. and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed. The user is responsible to third parties if pump (dumping stations, etc.) is used.
requirements for operating staff
The operating staff must carefully read the Operating instructions before using the appliance.
Qualification: apart from the detailed instructions by a professional, no special qualification is necessary for appliance using.
Minimum age: Persons over 16 years of age can only work on the appliance. an exception includes youngsters trained in order to reach knowledge under supervision of the trainer during occupational education.
Training: Using the appliance only requires corresponding training by a professional or the Operating instructions. no special training is necessary.
emergency procedure
conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. for the sake of eventual accident, in accordance with Din 13164, a workplace has to be fitted with a first-aid kit. it is essential to replace any used material in the first-aid kit immediately after it has been used. if you seek help, state the following pieces of information:
- accident site
- accident type
- number of injured persons
- injury type(s)
Maintenance
before carrying out any work on the machine, disconnect the plug from the socket.
- Prior to every use, visually check the machine to rule out any defects, in particular on the power cable and the plug.
- The machine must not be used under any circumstances if the machine or the safety devices are damaged.
- Refer all servicing to customer service. Use only original accessories and original spare parts.
- To ensure long service life of the pump seal we recommend rinsing the pump with clean water in regular intervals. at winter storing, it is necessary to make sure there is no water in the appliance as the frost could damage the appliance. Prior to transportation, it is necessary to unplug the pump from the grid! The device has to be completely emptied and stored with frost-proof protection. adhesion of mechanical seals can be prevented if you rinse the pump with appropriate oil (for example, with vegetable oil).
- Only a regularly maintained and treated appliance can serve as a satisfactory aid. insufficient maintenance and care can lead to unforeseen accidents and injuries.
guarantee
Warranty period of 12 months applies to commercial use and 24 months applies
to private use and commences on the day of purchase of the device. The
guarantee solely covers inadequacies caused by material defect or
manufacturing defect. Original payment voucher with the sales date needs to be
submitted for any claim in the guarantee period. The guarantee does not cover
any unauthorised use such as appliance overloading, use of violence, damage as
a result of any unauthorised interference or caused by foreign items. failing
to follow the operating and assembly instructions and common wear are also not
included in the guarantee.. GÜDe cannot be held responsible for damages
incurred in consequence of unqualified installation or unskilled handling of
the pump. The device has to be checked on a regular basis to ensure perfect
functioning. let us refer to the fact we do not assume any responsibility –
according to standards in force – for damage eventually caused by our
appliances in the belowmentioned cases:
- Unprofessional repairs executed by unauthorised service centres;
- Use in conflict with the designed purpose, or failure to observe the use as designed;
- Pump overload with a continuous run;
- Damage as a result of icing or any other fault caused by climatic influences; identical regulations apply for accessory parts
To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the owner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).
service
Do you have any technical questions? any claim? Do you need any spare parts or operating instructions? We will quickly help you and without needles bureaucracy at our web pages at www.guede.com in the Servicing part. Please help us be able to help you. in order to identify your device in case of claim we need the serial no., product no. and year of production. all this data can be found on the type label. Please enter it here for future reference:
symbols
- Read the Operating instructions
- before carrying out any work on the machine,
- disconnect the plug from the socket.
- cable pulling / transport prohibited
- Staying in the transportation medium prohibited
- Warning against dangerous electric voltage
- Warning against automatic starting
- accessory – not included in standard equipment, available as an accessory.
- any damaged or disposed electric or electronic devices must be delivered to appropriate collection centres.
- Protect against humidity
- This side up
inspection and maintenance plan
Time interval | Description | Any other details |
---|---|---|
as needed | cleaning and rinsing out | function check of the floating switch |
failures – causes – removal
failures | Causes | removal |
---|---|---|
engine does not start | no power supply. blocked pump wheel |
floating switch in shutdown position
| check the voltage
Visually inspect the pump wheel for foreign objects
check the water level
Pump does not suck| Pump without water Water level too low
blocked pump wheel
| let the air bubbles release 4
Switch the pump off, water level must go up. Remove the obstruction
Thermal detector swit- ching the pump off
5
| Plugged strainer
Water temperature too high
Pump running continuously at maximum pressure.
| clean the strainer and let the pump cool down
Reduce the water temperature Make more breaks
insufficient amount of water pumped| Dirty strainer
Water level quickly drops down Maximum head of delivery exceeded broken piping
| clean the strainer ensure sufficient inflow
check the transport line 3
check the transport line
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>