JBC MSE Electric Desoldering Module for DDU & DMU Instruction Manual

June 5, 2024
JBC

JBC - logo

www.jbctools.com

INSTRUCTION MANUAl

JBC MSE Electric Desoldering Module for DDU &amp DMU

MSE
Electric Desoldering Module
for DDU & DM

This manual corresponds to the following reference:
MSE-A

Packing List

The following items are included

| |
---|---|---
Electric Desoldering
Module ……………………….. 1 uni| Module Cable
connector …………………… 1 unit
Ref. 002422| Suction Filter ………………1 unit
Ref. 082183
JBC MSE Electric Desoldering Module for DDU &amp DMU -
Fig2| JBC MSE Electric Desoldering
Module for DDU &amp DMU - Fig4|
Paper Filter Box . ………. 1 unit
Ref. 0005966
Ref. contains 50 filter| Cotton Filter Set . ………. 1 unit
Ref. 0781046
Ref. contains 10 filter| Manual . ……………………… 1 unit
Ref. 002798

Features and Connection

JBC MSE Electric Desoldering Module for DDU &amp DMU -
Fig6

JBC MSE Electric Desoldering Module for DDU &amp DMU -
Fig7

Compatibility

Select the equipment that best suits your soldering or desoldering needs.

Module| Stand| Tool| TipsRange|

Control Units

| Peripherals
---|---|---|---|---|---
DDS| DMU| P405
MOUSE| DSS| DS360| C360| |

|
DRS| DR560| C560| | |

Initial Set up

JBC MSE Electric Desoldering Module for DDU &amp DMU -
Fig9
Peripherals
After connecting the module, enter the Peripherals Menu and select the port which you want to join the module.
For DDU Control Unit

  1. Select the module from the list of peripheral connections. Remember your first connection is denoted as “a”, the second being “b”, etc. (e.g. MSE_a, MSE_b,…)
  2. Press Menu or Back to save changes. Once set up, you can change the module settings by entering the Peripherals Menu.
    JBC MSE Electric Desoldering Module for DDU &amp DMU -
Fig10

For DMU Control Unit
When a new module is detected, a pop-up screen appears.

  1. To configure your Electric Suction Module press Setup in the popup window.
  2. Select the module from the list of peripheral connections. Remember your first connection is denoted as “a”, the second is “b”, etc. (e.g. MS_a, MS_b,…). Do the same  with the pedal (e.g. PD_a,…)JBC MSE Electric Desoldering Module for DDU &amp DMU - Control Unit
  3. Select the port of the tool you want to link to the peripheral.
  4. Press Menu or Back to save changes.
    Once set up, you can change the module settings by entering the Peripherals Menu.

JBC MSE Electric Desoldering Module for DDU &amp DMU - Control
Unit1

Maintenance

Before carrying out maintenance or storage, always unplug the equipment.

  • Keep the casing clean by using a damp cloth. Especially use a soft cloth for the front side.
  • Periodically check all cable and tube connections.
  • Keep filters clean to ensure proper solder suction and replace them when necessary.

Important: Do not use sharp pointed objects to open the suction filter.
JBC MSE Electric Desoldering Module for DDU &amp DMU - Suction
Filter

  • Use original JBC spare parts only.
  • Do not work with defective or damaged pieces.
  • Repairs should only be performed by a JBC-authorized technical service.
  • Maintenance must not be carried out by children unless supervised.

Safety

It is imperative to follow safety guidelines to prevent electric shock, injury, fire, or explosion.

  • Do not use the units for any purpose other than soldering or rework. Incorrect use may cause a fire.

  • The power cord must be plugged into approved bases. Be sure that it is properly grounded before use. When unplugging it, hold the plug, not the wire.

  • Do not work on electrically live parts.

  • soldering tip or nozzle, the metal part of the tool, and the stand may still be hot even when the station is turned off. Handle with care, including when adjusting the stand position.

  • Do not leave the appliance unattended when it is on.

  • Do not cover the ventilation grills. Heat can cause inflammable products to ignite.

  • Avoid flux coming into contact with skin or eyes to prevent irritation.

  • Be careful with the fumes produced when soldering.

  • Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working to avoid personal harm.

  • Utmost care must be taken with liquid tin waste which can cause burns.

  • This appliance can be used by children over the age of eight and also persons with reduced physical, sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning the use of the appliance and understand the hazards involved.
    Children must not play with the appliance.

  • Maintenance must not be carried out by children unless supervised.

Notes _____

Specifications

MSE
Electric Desoldering Module for DDU & DMU
Ref.: MSE-A

– Net Weight:
– Module Dimension (L x W x H):
– Vacuum:
– Flow rate:
– Ambient Operating Temperature:
– Pedal Connection
– Total Package Dimensions / Weight: (L x W x H)
Complies with CE standards.
ESD safe.| 1.22 kg / 2.69 lb
225 x 145 x 55 mm / 8.86 x 5.71 x 2.17 x in
75% / 570 mmHg / 22.4 inHg
9 SLPM
10 – 40 ºC / 50 – 104 ºF
280 x 195 x 115 mm / 1.53kg
11.02 x 7.68 x 4.53 in / 3.36 lb
---|---

JBC - logo
Warranty

JBC’s 2-year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labor.
The warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased.

This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must be collected and returned to an authorized recycling facility.

0027988-130522
www.jbctools.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals