PeakTech 9035 Energy Meter Instruction Manual
- June 5, 2024
- PeakTech
Table of Contents
Unser Wer ist messbar…
PeakTech® 9035
Operation manual
Safety Precautions
This product complies with the requirements of the following directives of the
European Union for CE conformity: 2014/30/EU (electromagnetic compatibility),
2014/35/EU (low voltage), 2011/65/EU (RoHS).
To ensure safe operation of the equipment and eliminate the danger of serious
injury due to short-circuits (arcing), the following safety precautions must
be observed.
Damages resulting from failure to observe these safety precautions are exempt
from any legal claims whatever.
- Do not use this instrument for high-energy industrial installation measurement.
- Prior connection of the equipment to the mains, check that the available mains voltage corresponds to the voltage setting of the equipment.
- Connect this instrument only to main outlet with protection earth contact (PE).
- Do not operate the meter before the cabinet has been closed and screwed safely as terminal can carry voltage.
- To avoid electric shock, do not operate this product in wet or damp conditions. Conduct measuring works only in dry clothing and rubber shoes, i. e. on isolating mats.
- Comply with the warning labels and other info on the equipment.
- Do not subject the equipment to direct sunlight or extreme temperatures, humidity or dampness.
- Do not subject the equipment to shocks or strong vibrations.
- Do not operate the equipment near strong magnetic fields (motors, transformers etc.).
- Keep hot soldering irons or guns away from the equipment.
- Allow the equipment to stabilize at room temperature before taking up measurement (important for exact measurements).
- Use caution when working with voltages above 35V DC or 25V AC. These Voltages pose shock hazard.
- Fetch out the battery when the meter will not be used for long period.
- Periodically wipe the cabinet with a damp cloth and mid detergent. Do not use abrasives or solvents.
- The meter is suitable for indoor use only
- Unplug before cleaning
- The power meter shall be used only in area with installation category II (CAT II) according to IEC664, in which the transient voltages do not exceed 300V. The mains supply for residential areas generally belongs to this category.
- Do not store the meter in a place of explosive, inflammable substances.
- Do not modify the equipment in any way
- Opening the equipment and service – and repair work must only be performed by qualified service personnel
- Do not operate the meter, if the environmental conditions don´t correspond to the technical specifications (>75%RH, >40°C or <10°C)
- Measuring instruments don’t belong to children hands.
For indoor use only
Correct Disposal of this product
This marking indicates that this product should not be disposed with other
household wastes throughout the EU. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources. To return
your used device, please use the return and collection systems or contact the
retailer where the product was purchased.
They can take this product for environmental safe recycling.
Warranty
The manufacturer provides warranty of 3 years.
The warranty starts from the date on which the appliance is sold to the end
user.
The warranty only covers defects in material or workmanship.
The repairs under warranty may only be carried out by an authorized service
centre. When making a claim under warranty, the original bill of purchase
(with purchase date) must be submitted.
The warranty will not apply in cases of:
- Normal wear and tear
- Incorrect use, e.g. overloading of the appliance, use of non-approved accessories.
- Use of force, damage caused by external influences
- Damage caused by non-observance of the user manual, e.g. connection to an unsuitable mains supply or non-compliance with the installation instructions
- Partially or completely dismantled appliances.
General
New designed, high-precision Energy Meter for detecting the energy consumption of electrical appliances and to calculate the total cost of the electricity consumption of a device by entering the current price. Through the integrated power factor calculation all modern electronic consumers such as switching power supplies, TVs, fluorescent lights, LED systems and of course, resistive loads such as electric heaters and hobs are precisely measured. In addition, due to the high resolution and the low response, even very small or standby loads are measured from approximately 1W.
Features
- Measure the energy costs (€), energy consumption (kWh), Voltage (V) Frequency (Hz), load current (A), power factor
- Display of the maximum consumption (Wmax) with trigger time
- Display of time, day and consumption time
- Power factor measurement from about 1W
- Adjustable day and night tariff
- Integrated overload indicator and child lock
- Reset button to reset all device functions
- CO2 emission calculation in CO2/kg
- Built-in rechargeable battery for memory conservation
- High resolution of 0.005 A
- High basic accuracy + / – 0.5%
- GS-certified, Intertek Deutschland GmbH
- Safety: GS, EN61010-1, CAT II 300V
Front panel description
- Earthed socket with child protection
- Reset button to reset all device settings
- ▲-button for setting the various values
- SET button to select the cost or time setting
- MODE button to switch the measurement functions
- LCD multi-range display
Date and Time
This energy cost meter has a built-in system clock, which is required to switch the day and night tariff. Furthermore, the device stores the maximum consumption value with time for better evaluation of the consumption behavior.
- Connect the unit to a wall outlet. The unit automatically turns on and the voltage measurement is displayed.
- Press the SET button and starts the day flashing.
- Press the ▲ key to the current day is displayed.
- After further pressing the SET button flashes the hours of time.
- Press the ▲ key until the correct hour is displayed.
- After further pressing the SET button, minutes flash on the display of time.
- Press the ▲ key to the current minute is displayed.
- After further pressing the SET button, the time has been saved.
Press the ▲ button within measurement range menus to switch between the 24h and the 12h display.
Set prices
In this energy cost meter can be set two different price rates, which can be used to calculate costs in split day and night tariff. This setting is valid for the whole week or only selected weekdays. The value received is neutral and therefore can be used worldwide.
Price 1 set:
- Press the MODE button for about 5 seconds in the voltage measurement, current measurement and power measurement menu to activate the tariff preferences.
- Press the SET button to make the adjustment of the cost of Price1.
- The first digit (ten units of money per kWh) starts flashing.
- Press the ▲ key to change this value (e.g.: 0 -at a rate of 00.25 € per kWh)
- Press the SET button to the second digit (a unit of money per kWh) input.
- Press the ▲ key to change this value (e.g.: 0 -at a rate of 00.25 € per kWh)
- Press the SET button to select the third digit (0.1 unit of money per kWh).
- Press the ▲ key to change this value (e.g.: 2 -at a rate of 00.25 € per kWh)
- Press the SET button to select the third digit (0.01 cash per unit kWh).
- Press the ▲ key to change this value (e.g.: 5 -at a rate of 00.25 € per kWh)
- Press the SET button to set the decimal point change.
- Press the ▲ key to change the decimal point (in € not necessary)
- Press the SET button for the appropriate day of the week for Price 1 change.
- Repeatedly press the ▲ button to cycle through the weekdays (normal value: Mo-Su) (Mo, Tu, We, Th, Fri, Sat, Sun, Mon-Fri, Mon-Sat, Sat-Su, Mo-Su)
- Press the SET button to set the daily hour of the start time for Price 1.
- Press the ▲ key to set the hour (e.g.: 6 – at begin of Price 1 at 6 AM)
- Press the SET button to the minute of the start time for Price 1 set.
- Press the ▲ key to set the minute (e.g.: 00 – at begin of Price 1 at 6 AM)
- Press the SET button to save the settings.
Price 2 set:
- Press the MODE button for about 5 seconds in the voltage measurement, current measurement and power measurement menu to activate the tariff preferences.
- Press the MODE button one time to switch from PRICE 1 to PRICE 2.
- Press the SET button to make the adjustment of the cost of Price2.
- The first digit (ten units of money per kWh) starts flashing.
- Press the ▲ key to change this value (e.g.: 0 -at a rate of 00.21 € per kWh)
- Press the SET button to the second digit (a unit of money per kWh) input.
- Press the ▲ key to change this value (e.g.: 0 -at a rate of 00.21 € per kWh)
- Press the SET button to select the third digit (0.1 unit of money per kWh).
- Press the ▲ key to change this value (e.g.: 2 -at a rate of 00.21 € per kWh)
- Press the SET button to select the third digit (0.01 cash per unit kWh).
- Press the ▲ key to change this value (e.g.: 1 -at a rate of 00.21 € per kWh)
- Press the SET button to set the decimal point change.
- Press the ▲ key to change the decimal point (in € not necessary)
- Press the SET button for the appropriate day of the week for Price 2 change.
- Repeatedly press the ▲ button to cycle through the weekdays (normal value: Mo-Su) (Mo, Tu, We, Th, Fri, Sat, Sun, Mon-Fri, Mon-Sat, Sat-Su, Mo-Su)
- Press the SET button to set the daily hour of the start time for Price 2.
- Press the ▲ key to set the hour (e.g.: 10 – at begin of Price 2 at 10 PM)
- Press the SET button to the minute of the start time for Price 2 set.
- Press the ▲ key to set the minute (e.g.: 00 – at begin of Price 2 at 10 PM)
- Press the SET button to save the settings.
Overload settings
With a preset overload an OVERLOAD symbol flashes on the display when the set value is exceeded. This value is normally set to 16A.
- Press the MODE button for about 5 seconds in the voltage measurement, current measurement and power measurement menu to activate the overload settings.
- Press the MODE button twice to switch from PRICE1 and PRICE2 to the OVERLOAD settings.
- Press the SET button. The first digit (tens of amperes) starts to flash.
- Press the ▲ key to change this value.
- Press the SET button again to select the second digit (one amp).
- Press the ▲ key to change this value.
- Press the SET button again to select the third digit (0.1 amps).
- Press the ▲ key to change this value.
- Press the SET button again to select the fourth digit (0.01 amps).
- Press the ▲ key to change this value.
- Confirm with the SET key
LCD display and menu control
After connecting the device to a power outlet, the device switches on
automatically and displays the VOLTAGE menu.
Here you can check the measured line voltage, line frequency, weekday and the
current time.
Press the MODE button to switch to the CURRENT range.
Here you can check the load current in amps, power factor, weekday and the
current time.
Press the MODE button to switch to the WATT range.
Here you can check the current power of the load in watts, the power factor,
weekday and the current time.
Press the MODE button to switch to the WATT MAX range.
Here you can check the measured maximum power of the load in watts, the power
factor and the trigger time of the maximum power measurement.
Press the MODE key to switch to the kWh (kilowatt hours) range.
Here you can check the previously measured power of the consumer in kWh, power
factor, weekday and the current time.
Press the MODE key to switch to the CO2/kg range.
Here you can check an orientation value for the generated CO2 emission values
of the previously measured power of the consumer, the power factor, weekday
and the current time. The CO2/kg Value refers to a 100% supply by coal-fired
power and is calculated by the theoretical CO2 emissions of 0.792 kg / kWh. If
your energy supplier offers a different energy mix, you can subtract this
percentage value.
Example: 12.5kgCO2 at 100% coal power = 6.25kgCO2 at 50% coal power & 50% wind
power
Press the MODE key again to switch to the Total Trice area. To calculate a
Total costs, you must have set at least the tariff 1 first. The total costs as
sum of the both tariffs are indicated. Depending upon your settings, you can
read this value as the €- value. In addition, the “Total on Time” for both
tariffs will be displayed.
To reset these values press the MODE button for about 2 seconds.
Press the MODE key again to switch to the total price Tariff 1 area. To
calculate a total value, you must have set a tariff 1 first. The total cost of
the tariff 1 appears in this indication. Depending upon your settings, you can
read this value as the €- value. In addition, the “Total on Time” for tariff 1
will be displayed during the tariff.
To reset these values press the MODE button for about 2 seconds.
Press the MODE key again to switch to the total price Tariff 2 area. To
calculate a total value, you must have set a tariff 1 first. The total cost of
the tariff 2 appears in this indication. Depending upon your settings, you can
read this value as the €- value. In addition, the “Total on Time” for tariff 2
will be displayed during the tariff.
To reset these values press the MODE button for about 2 seconds.
Integrated storage battery:
- The integrated storage battery serves to backup the measured values in case of power failure or when the unit is unplugged from the outlet
- When the unit is connected to the electrical grid, the storage battery reloads itself automatically
- The storage battery is integral and hasn’t to be replaced or disposed separately
Technical Specification
Nominal input voltage | 230V AC; 50Hz |
---|---|
Voltage measurement | 200 – 276 V AC, 45 – 65Hz |
Maximum load | 16A, 3680W |
Lower current range | 0.005A |
Power consumption | <0.5W |
Current display | 0.005A … 16.000A |
Watt Range | 0.0 … 3680.0 W |
Power factor calculation | 0.10 … 1.00 |
Consumption display | 0.0 … 9999.9 kWh |
Accuracy | + / – 0.5% |
Operation temperature | +10°C … +40°C; <75%RH |
Internal Battery | Ni-Mh 3.6V |
Dimensions (WxHxD) | 120 x 60 x 75 mm |
Weight | 160g |
All rights, also for translation, reprinting and copy of this manual or parts
are reserved.
Reproduction of all kinds (photocopy, microfilm or other) only by written
permission of the publisher.
This manual considers the latest technical knowing.
Technical changings, which are in the interest of progress reserved.
We herewith confirm, that the units are calibrated by the factory according to
the specifications as per the technical specifications.
© PeakTech ® 09/2021 MP/SM/Ehr.
PeakTech Prüf- und Messtechnik GmbH
– Gerstenstieg 4 – DE-22926 Ahrensburg / Germany
+49-(0) 4102-97398-80 +49-(0) 4102-97398-99
info@peaktech.de www.peaktech.de