radiant® WNP10 Plug-In Smart Switch with Netatmo; Tungsten, Resistive,
Incandescent: 1800W;
General Purpose: 1800VA; Motor Control: 1/2 hp; LED, CFL, ELV: 5A
No: 341308 3/21
User Guide
WNP10
radiant® Plug-In Smart Switch
WNP10 Plug-In Smart Switch
Installation Instructions
Catalog Number(s)
WNP10
BEFORE YOU START
Review this guide in its entirety. Consult an electrician with any questions
or if you are unsure of your abilities.
CAUTION: To reduce the risk of injury and/or overheating and damage to
other equipment:
- For dry, indoor use only.
- Connect the Smart Plug-In Switch to a 120 VAC, 60 Hz power source ONLY
- To reduce the risk of electrical shock, this equipment has a grounding-type plug that has a third (grounding) pin. If the plug does not fit in the outlet, contact a qualified electrician to install the proper outlet.
INSTALLATION & SETUP
-
Plug in the smart plug-in switch
Insert the lamp or device to be controlled into the outlet on the Smart Plug- In Switch. -
Test the smart plug-in switch
a. With the lamp or device on, press the button on the Legrand Smart Plug-In Switch to turn your device on.
b. Press the button again to turn your lamp or device off.
TROUBLESHOOTING TIP: If the device is not responding to the switch, confirm that the outlet is powered and that the device is functional. This radiant ® device is designed to work with a radiant ® Smart Gateway with Netatmo. -
Set Up Your System
a. Download and launch the Legrand Home + Control app. The app is available on the App Store or on Google Play.
b. Press the EZ button for 1 second, and the LED indicator will blink magenta to indicate set up mode. Follow the instructions in the app to finish setting up the device. If the device is connected successfully, the LED will stop blinking.
c. Use the app to control your smart device.
For the most recent instruction sheets or more information on this product, please see this link or scan the QR code: https://www.legrand.us/p/wnp10
https://www.legrand.us/p/wnp10
GETTING TO KNOW YOUR PLUG-IN
Item | Name | Description |
---|---|---|
1 | Button | Turns the device on or off. |
2 | LED Power Indicator | Lit when the load is off. |
3 | Outlet | Plug your device into the outlet.. |
4 | EZ Button/ LED | Press to start set up. Indicates the current state of the |
device. Refer to the “LED Light Explanations” for details.
LED LIGHT EXPLANATIONS
State of Light | Explanation |
---|---|
Solid Red | Factory reset, not in network. |
Blinking Green | The device is attempting to connect to the network. |
Solid Green | The device in the network is temporarily open. |
Reset to Factory Default:
Deleting a device from the app will reset it to factory defaults. To manually
reset the device to factory defaults, press and hold the EZ button for 10
seconds until you see the LED blink red then release. The LED will change to
solid red when the reset is complete.
SPECIFICATIONS
Load | Rating |
---|---|
Tungsten/Resistive | 1800W |
General Purpose | 1800VA |
Motor | 1/2 HP |
LED/CFL/ELI: | 5A |
Legrand reserves the right to change specifications without notice.
REGULATORY INFORMATION
FCC NOTICE: This device complies with Part 15 of the FCC rules. Operation
is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesirable operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and the receiver
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 10 mm between the transmitter’s radiating structure(s)
and the body of the user or nearby persons.
NOTE: Any changes or modifications to this device that are not expressly
approved by the manufacturer will void the warranty and the user’s authority
to operate the equipment.
Contains FCC ID: 2AU5D982057
IC NOTICE: This device complies with Industry Canada license-exempt RSS
standards. Operation is subject to the following two conditions: (1) this
device may not cause interference; and (2) this device must accept any
interference, including interference that may cause undesired operation of the
device.
RF EXPOSURE STATEMENT: This equipment meets the SAR evaluation limits
given in RSS-102 Issue 5 requirements at the minimum separation distance of 10
mm to the human body. Note: Any changes or modifications to this device that
are not expressly approved by the manufacturer, will void the warranty and the
user’s authority to operate the equipment.
IC: 25764-982057
HVIN: 982057