imilab C20 Pro Home Security Camera User Manual
- June 5, 2024
- IMILAB
Table of Contents
imilab C20 Pro Home Security Camera
Product Overview
Front View
-
Status
indicator -
Lens
-
MicroSD Slot
(Can be revealed by pushing the lens upward) -
MIC
-
Reset Hole
Rear View
- Loudspeaker
- Micro-USB Charging port
Package Contents: IMILAB C20 x 1, power adapter x 1, power cable x 1, wall mounting accessories pack x 1, user manual x 1.
Installation
IMILAB C20 can be placed on a number of horizontal surfaces, such as a writing desk, dining table, and coffee table. It can also be mounted on the wall.
Mounted IMILAB C20 on a Wall:
-
Drill two holes on the wall by using the base of the IMILAB C20 as a template. It is recommended that you mark the locations of the hole with a pencil before drilling. The diameter of each hole is approximately 6 mm, and the depth is approximately 30 mm.
-
Insert the two plastic anchors into the holes on the wall.
-
Make sure to position the base unit so that the arrow is pointing up. Secure the base unit in place by tightening the screws into the plastic anchors.
-
Matching the grooves on the bottom of the camera unit with the raised area on the base unit. Press down until the two surfaces are flush, then turn the camera unit in either direction to lock it in position.
Warning:
To avoid any damages or injuries, the device must be securely fastened to the
floor/wall as specified in the installation instructions.
When mounting the security camera on a wall:
Please note that the wall must be able to support at least triple the
product’s total weight.
Product Instructions
Turning the Device On
IMILAB C20 will automatically activate once the power cable is inserted into
the Micro-USB charging port.
- If the indicator light is flashing orange, that means the device is activated successfully. If you do not see a flashing orange light, please reset the device.
- Once the IMILAB C20 is turned on, please do not attempt to rotate its head by force. If the camera position is incorrect, adjustments can be made through the app.
Indicator Light
- Steady blue on: connected/device status is normal
- Flashing blue: network error
- Flashing orange rapidly: waiting for connection
- Flashing orange slowly: system upgrade in progress
Installing a MicroSD Card
Make sure that the power to IMILAB C20 is already disconnected. Adjust the
camera lens upward until the MicroSD slot is revealed, then insert the MicroSD
card into the slot (the side with contact points must be facing down).
Note: Please turn off the IMILAB C20‘s power supply before inserting or
removing the MicroSD card. Please use a genuine Micro SD card manufactured by
a qualified supplier, with a reading/writing speed of no less than U1/Class 10.
(Maximum support capacity is 256 GB)
Restore Factory Settings
Press and hold the reset hole with fine needle, then you can hear the “reset
succeed” voice.
Data stored on the MicroSD card is not deleted.
Install IMI Home App
Connect with IMI Home app. This product works with IMI Home app. Control your
device with IMI Home app.
Scan the QR code to download and install the app. You will be directed to the
connection setup page if the app is installed already. Or search “IMI Home” in
the app store to download and install it. Open IMI Home app, tap “+” on the
upper right, and then follow prompts to add your device.
Add Device
- Open IMI Home app, tap “+” on the upper right. Tap”[-]”and scan the QR code under the device by you phone, then you can follow the steps to add your device.
- Open IMI Home app, tap “+” on the upper right. Tap”IMILAB C20”and then you can follow the steps to add your device.
Note: The version of the app might have been updated, please follow the instructions based on the current app version.
FCC Statement
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment. This
device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy, and if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment .This equipment should be installed and operated with
minimum distance 20cm between the radiator& your body.
WEEE Information
All products bearing this symbol are waste electrical and electronic equipment (WEEE as in directive 2012/19/EU) which should not be mixed with unsorted household waste. Instead, you should protect human health and the environment by handing over your waste equipment to a designated collection point for the recycling of waste electrical and electronic equipment, appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. Please contact the installer or local authorities for more information about the location as well as terms and conditions of such collection points.
EU Declaration of Conformity
Hereby, Shanghai Imilab Technology Co., Ltd. declares that the radio equipment
type IMILAB C20 is in compliance with Directive 2014/53/EU. The full text of
the EU declaration of conformity is available at the following internet
address:
http://www.mi.com/global/service/support/declaration.html
Specifications
- Name: IMILAB C20
- Model : CMSXJ36A
- Net Weight: 259g
- Lens Angle: 115°
- Resolution: 1920 x 1080
- Power input: 5 V 2 A
- Expandable Memory: MicroSD card (up to 256GB)
- Dimensions: 108 mm x 75 mm x 75 mm
- Operating Temperature: -10 °C to 40 °C
- Compatible With: Android 4.4 or iOS 9.0 or above
- Wireless Connectivity: Wi-Fi IEEE 802.11 b/g/n 2.4GHz
Manufacturer: Shanghai Imilab Technology Co., Ltd.
(a Mi Ecosystem Company)
Address: Room 001A, Floor 11, Block 1, No. 588 Zixing Road, Minhang District,
Shanghai,
China
For further information, please go to www.imilab.com.
Support: help@imilab.com
For Business: globamarketing@imilab.com
References
- Alza.cz – rychlý a pohodlný nákup odkudkoliv | Alza.cz
- Alza.sk – rýchly a pohodlný nákup odkiaľkoľvek | alza.sk
- Alza | Alza.co.uk
- Alza.cz – rychlý a pohodlný nákup odkudkoliv | Alza.cz
- Alza.cz
- alza.de
- alza.hu
- alza.sk
- 创米imilab官网-智能门-智能家居品牌-全屋智能品牌-扫地机器人
- IMIKI
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>