AL-KO TBP 6000-7 Electric Submersible Pump Instructions

June 5, 2024
AL-KO

TBP 6000-7 Electric Submersible Pump
Instruction Manual

© 2016
AL-KO KOBER GROUP Kötz, Germany
This documentation or excerpts therefrom may not be reproduced or disclosed to third parties without the express permission of the AL-KO KOBER GROUP.

AL KO TBP 6000-7 Electric Submersible Pump - figure 1| AL KO TBP 6000-7 Electric Submersible Pump - figure
2
---|---

ABOUT THIS HANDBOOK

  • Read this documentation before starting up the machine. This is a precondition for safe working and flawless operation.
  • Observe the safety warnings in this documentation and on the product.
  • This documentation is a permanent integral part of the product described and must be passed on to the new owner if the product is sold.

Explanation of symbols

CAUTION!
Following these warning instructions can help to avoid personal injury and/or damage to property.
ADVICE
Special instructions for ease of understanding and handling.

PRODUCT DESCRIPTION

Product overview (01)

1 Mains connection cable
2 Pump outlet/pressure line connection
3 Cable lugs
4 Cable 20 mm / 6 mm
5 Pump base
6 Suction holes
7 Pump housing
8 Check valve

Function
The immersion pump draws the conveying medium through the suction holes directly and feeds it to the pump outlet.

Designated use
The immersion pump is designed for private use in the house and garden. It must only be operated within the framework of the deployment limitations in accordance with the technical data.
The immersion pump is suitable for:

  • Water removal from streams and shafts

The immersion pump is only suitable for conveying the following fluids:

  • Clearwater, rainwater Any use not in accordance with this designated use shall be regarded as misuse.

Possible misuse
The immersion pump must not be used in continuous operation.
It is not suitable for conveying:

  • Drinking water
  • Saltwater
  • Foodstuffs aggressive media, chemicals
  • corrosive, flammable, explosive, or fuming fluids
  • that are hotter than 35 °C
  • water containing a sand and abrasive fluids.

SAFETY INSTRUCTIONS

CAUTION!
Risk of injury!
Use the machine and the extension cable only in perfect working order.
Damaged equipment may not be operated. Do not disable safety and protective devices!

  • Children, or people who are not familiar with the operating instructions, are not allowed to use the machine.
  • Never lift, transport or suspend the unit using the connection cable.
  • Unilateral modifications or conversions of the unit are prohibited.

Electrical safety

CAUTION!
Danger from contact with live parts!
Immediately disconnect the plug from the mains if the extension cable has been damaged or cut. We recommend a connection via an earth leakage circuit breaker (ELCB) with a  rated leakage current of < 30 mA.

  • The pump may not be operated while people are in the pool or pond.

  • The mains voltage at your location must comply with the information regarding mains voltage in the Technical Data. Do not use any other supply voltage.

  • The appliance must only be operated on electrical equipment in accordance with DIN/ VDE 0100, parts 737, 738, and 702. For fuse protection, a circuit breaker of 10 A  and an earth leakage circuit breaker with a rated leakage current of 10/30 mA must be installed.

  • Only use extension leads approved for outdoor use with a minimum cross-section of 1.5 mm 2.

  • Always fully unwind cable drums.

  • Damaged or fragile extension cables may not be used.
    ➯ Check the condition of your extension cable prior to every use.

  • If the connection cable must be extended, only a cable type H07RN-F and a molded sleeve must be used. This work must only be carried out by an electrician.

INSTALLATION

Mounting the pressure line (03)
The pump has a check valve on the pump outlet. This prevents the pressure line being emptied each time the pump stops.

  1. Mount the pressure line (03/1) on the pressure line connection (03/2).
  2. Attach the connection cable (03/3) to the pressure line with cable ties (03/4).
  3. Prior to the immersion of the pump in the well and shafts, attach the enclosed cable to the cable lugs (03/5).

STARTUP

Safety
CAUTION!
Exclude, by suitable means, that, in the event of a fault in the immersion pump, consequential damage is caused by flooding.

  • Operate the immersion pump hanging on a cable.
  • Operate the appliance only if the immersion pump is fully immersed.
  • Always observe sufficient distance to the base of the shaft (min. 1 m).
  • Never allow the immersion pump to run against a closed-off pressure line.
  • When using in shafts, make sure the size is adequate.
  • Always cover the shaft with a secure footplate.

Dismantling the pump base (04)
In order to operate the pump in a narrow shaft of min. 100 mm diameter, the pump base must be removed.

  1. Unscrew (04/a) both fastening screws (04/1) of the pump base (04/2).
  2. Remove (04/b) pump base (04/2) from the pump (04/3).

OPERATION

Lowering the pump
When lowering and pulling up the pump in a shaft, make sure that the main supply cable is not subject to tensile stress and that no objects fall into the shaft. These can jam between the pump housing and shaft wall so that the pump cannot be pulled up again.

Switching the pump on
CAUTION!
The immersion pump must not draw in any solid bodies. Sand and other abrasive materials in the conveying medium will destroy the immersion pump.

  1. Fully unwind the mains connection cable.
  2. Make sure that the electrical plug connection mounted in the area is safe from flooding.
  3. Insert the mains plug into the plug socket.

Switching the pump off

  1. Remove the mains plug from the plug socket

MAINTENANCE AND CARE

Cleaning the pump
After conveying chlorine-containing swimming pool water or fluids that leave a residue, the pump must be flushed out with clear water.

  1. Clean the suction slots on the suction foot if
    necessary with clear water.

Checking the cable

  1. Pull the pump out of the shaft from time to time.
  2. Check the cable. If the cable is damaged, replace it with an original spare part.
  3. Check that the cable lugs on the pump are still durable.
    If the cable is damaged, carefully try to pull the pump out of the shaft via the pressure line. Never pull on the main supply cable.

STORAGE

If there is a danger of frost, the system must be completely drained and the pump must be stored in a frost-proof place.

HELP IN CASE OF MALFUNCTION

CAUTION!
Disconnect the mains plug before any fault rectification work! Faults in the electrical system must be rectified by a qualified electrician.
The appliance must not be included in the normal household rubbish but must be properly disposed of.
Important for Germany: Dispose of the appliance at a municipal recycling collection center.

Malfunction Possible cause Solution

Motor does not
run.| Impeller blocked| Remove dirt from the suction area.
The thermal protection switch has switched
off.| Wait until the thermal protection switch on the immersion pump switches on again. Take note of the maximum temperature of the conveying medium.
Has the immersion pump been inspected?
No mains power.| Check fuses, and have the power supply checked by a qualified electrician.
The pump running but
does not feed.| Blockage on the suction side.| Remove dirt from the suction area.
The pressure line closed off.| Open the pressure alone.
Pressure hose kinked.| Extend the pressure hose.
Delivery rate too
low| Hose diameter too small.| Use a hose with a bigger diameter.
Blockage on the suction side.| Remove dirt from the suction area.
Feed head to high.| Observe max. feed head, see technical data!

In the event of a malfunction that you cannot rectify, please contact our Customer Service department.

WARRANTY

We will address claims for any defects in materials and workmanship during the statutory period of limitation by means of repairs or replacements of our choice. The period of limitation is governed by the laws of the country in which the machine was purchased.

Our warranty applies only if:

  • The machine has been properly handled
  • The operating instructions have adhered to
  • Original replacement parts have been used

The warranty is no longer in effect if:

  • Efforts have been made to repair the machine
  • Technical modifications have been made to the machine
  • The machine has not been used for its intended purpose

The warranty does not cover:

  • Damage to paintwork through normal use
  • Parts subject to wear as indicated in the replacement parts list with a box [xxx xxx (x)]
  • Internal combustion engines – separate warranty conditions of the respective engine manufacturer apply

The warranty period begins with the purchase by the first buyer. The warranty period begins on the date that appears on the original purchase receipt. In the event of a warranty claim, please your contact supplier or the nearest authorized customer service center with this warranty declaration and the purchase receipt in hand. This warranty does not affect the legal warranty claims by the purchaser against the seller.

DECLARATION OF CONFORMITY

We hereby declare that this product in the version introduced into the trade by us complies with the requirements of the harmonized EU0 Directives,  EU safety 0standards, and product-specific standards.

Product
Immersion pump, electrical

Serial number
G3073075

Type
TBP 6000/7

Manufacturer
AL-KO Geräte GmbH
Ichenhauser Str. 14
D-89359 Kötz, Germany

EU directives
2014/35/EU
2014/30/EU
2011/65/EC

Duly authorised person
Andreas Hedrich
Ichenhauser Str. 14
D-89359 Kötz, Germany

Harmonised standards
EN 60335-1
EN 50636-2-41
EN 55014-1
EN 55014-2
EN 61000-3-2
EN 61000-3-3

Country Company Telephone Fax
A AL-KO KOBER Ges.m.b.H. (+43)3578/2515-100 (+43)3578/2515-31
AUS AL-KO INTERNATIONAL Pty. Ltd. (+61)3/9767-3700 (+61)3/9767-3799
B/L Eurogarden NV (+32)16/805427 (+32)16/805425
BG Valerii S&M Group SJ (+359)2 942 34 02 (+359)2 942 34 10
CH AL-KO KOBER AG (+41)56/418-31 53 (+41)56/4183160
CZ AL-KO KOBER Spol. S.R.O. (+420)382/210381 (+420)3 82 / 212782
D AL-KO GERATE GmbH (+49)8221/203-0 (+49)8221/97-8199
DK AL-KO GINGE A/S (+45) 98 8210 00 (+45)98 82 54 54
EST/LT/LV SIA AL-KO KOBER (+371)67/627-326 ((+371)67/807-018
F AL-KO S.A.S. (+33)3/8576-3500 (+33)3/8576-3581
GB Rochford Garden Machinery Ltd. (+44)1963/828050 (+44)1963/828052
H AL-KO KFT (+36) 29 /5370 -50 (+36)29/5370-51
HR Brun.ko.-prom d.o.o. (+385)1 3096 567 (+385)1 3096 567
AL-KO KOBER GmbH / SRL (+39)039/932 9-311 (+39) 0 39/9 32 9-390
IN AGRO-COMMERCIAL (+91)3322874206 (+91)3322874139
IQ Avro Gulistan Corn (+946)750 450 80 64
IRL Cyril Johnston & Co. Ltd. (+44)2890813121 (+44)2890914220
LY ASHOFAN FOR AGRICULT. ACC. (+218)512660209 (+218)512660209
MA BADRA Sarl (+212)022447128 (+212)022447130
MK Techno Geneks (+389)2 2551801 (+389)2 2520175
N AL-KO GINGE A/S (+47)64/86-2550 (+47)64/86-2554
NL 0.DE LEEUW GROENTECHNIEK (+31)38/444 6160 (+31)38/444 6358
PL AL-KO KOBER Sp. z.o.o. (+48)61/816-1925 (+48)61/816-1980
RO SC PECEF TEHNICA SRL (+40)344 40 30 30 (+40)244 51 44 86
RUS 000 AL-KO KOBER (+7)499/16708-42 (+7)499/96600-00
RUS ZAO AL-KO St. Petersburg GmbH (+7)812/446-1084 (+7)812/446-1084
S GINGE Svenska AB (+46)31/57-3580 (+46)31/57-5620
SK AL-KO KOBER Slovakia Spol. S.R.O. (+421)2/4564-8267 (+421)2/4564-8117
SLO Darko Opara s.p. (+386)1 722 58 50 (+386)1 722 58 51
SRB Agromarket d.o.o. (+381)34 308 000 (+381)34 308 16
TR ZIMAS A.S. (+90)232 4580586 (+90)232 4572697
UA TOV AL-KO KOBER (+380)44/392-07-08 (+380)44/392-07-09

AL-KO GERATE GmbH I Head Quarter I Ichenhauser St r. 14 I 89359 Utz I Deutschland
Telefon: (+49)8221/203-0 I Telefax: (+49)8221/97-8199 I www.al- ko.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals