Green Cell AiO 600VA UPS
SAFETY
Risk of Electric Shock
The UPS device does not have a structure that allows the user to perform
independent repairs or replacement. Do not open the housing yourself. The UPS
is powered by a sealed, maintenance-free 12V lead-acid battery in AGM
technology. If you connect the device to a non bipolar, three core, grounded
outlet, there is a risk of electric shock. In the event of a fault, the device
should be switched off with the built-in button, then disconnected from the
mains and all devices connected to the UPS must be disconnected. The device is
not protected against moisture. Avoid use in damp rooms. Do not place it near
containers with liquid and moisture sources. The device is suitable for work
in room conditions. Do not plug the device into its own power outlet. Do not
plug the mains plug into the output socket of the device. The UPS has internal
guards and stabilizers and limited power. Therefore, do not connect any
additional surge protection devices, extension cords or power distributors.
The UPS is not suitable for powering equipment outside the category of IT
equipment. It can not be used to power medical devices or household appliances
kettles, vacuum cleaners, microwave ovens. To prevent overheating, do not
cover the unit, block the access to the air, expose to sunlight, or install it
near heat sources such as radiators or heaters. Disconnect the device from the
power source before cleaning. Do not use liquid detergents to clean the
device. Do not throw the battery into the fire as it can explode. Do not
disassemble the built-in battery. The electrolyte is dangerous to eyes and
skin. Follow these safety instructions to avoid a short circuit or electric
shock
- When handling the battery, remove all metal parts rings, watches by hand.
- Use only tools with insulated handles.
- Use insulating gloves.
- Do not place metal tools on the battery case near the terminals.
- Before disconnecting the battery, turn off the UPS and disconnect the power plug from the electrical outlet.
- Repairs and replacement of the battery must only be carried out by trained technicians at authorized service centers.
- Replacement should be with a battery of the same type and parameters.
- During the exchange, the ambient temperature must not exceed 40 degrees Celsius.
- When installing the device, make sure that the leakage current does not exceed 3.5 mA.
The appliance is marked with the crossed-out waste bin symbol. This mark
indicates that this device can not be disposed of with other household waste
after its useful life.
ATTENTION
This device must not be disposed of with the trash! The product should be
recycled thro-ugh separate collection of prepared items. Proper handling of
used electrical and electronic equipment helps prevent harmful effects on
human health and the environment caused by the presence of hazardous
components and the improper storage and handling of these equipment.
PRODUCT DESCRIPTION
The AiO Series Uninterruptible Power Supply UPS is designed to work with PCs. Its light weight and compact dimensions make it an ideal solution in the office or at home when the workplace is very limited. The UPS uses Line Interactive and AVR technologies to protect your equipment and enable operation over a wide range of input voltages. Key Features of AiO UPS Devices
- Advanced controls guarantee high switching speed and operational safety.
- AVR technology makes your devices up to 15% resistant to mains voltage fluctuations.
- Green Power function for energy saving.
- Cold start function;
- Automatic switching after restoration of the power supply compact size, light weight.
- Overload protection.
BASIC FUNCTIONS OF THE GREEN CELL UPS
Device
After removing it from the packaging, make sure that no damage in transit is visible on the case of the device. If you notice any damage, do not connect the device and contact the seller.
Charging
The device leaves the factory with fully charged batteries. However, due to the self-discharge phenome-non, it may be necessary to charge it after receiving. Switch on the device and connect it to the mains. Leave the UPS for about 6 hours without load to fully charge it.
Location
The device should be used under controlled conditions to ensure adequate airflow. Be sure to avoid: large pollutants dust, sand, etc. Humidity, Corrosion sources high temperatures. At the same time, make sure the UPS is not near the computer monitors to avoid interference.
Connection
Connect the AiO power supply to a bipolar socket with ground pin. Then you can connect the computer and other devices to the output jacks.
ATTENTION
Do not connect devices via extension cords or distributors.
Commissioning
To start the device, press the POWER button on the front of the case. To turn off the UPS, press the button again.
Cold Start
Press the POWER button to force the battery to work.