- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 12: MOTION SENSORS SENSITIVITY.
- Parameter 13: MOTION SENSORS BLIND TIME (INSENSITIVITY)
- Parameter 14: ENABLE/DISABLE BASIC COMMAND
- Parameter 15: BASIC COMMAND VALUE
- Parameter 170: No.170 SET PARAMETER 171174 TO DEFAULT SETTINGS
- Parameter 171: BATTERY REPORT INTERVAL
- Parameter 172: TEMPERATURE REPORT INTERVAL
- Parameter 173: HUMIDITY REPORT INTERVAL
- Parameter 174: LUMINANCE REPORT INTERVAL
- Parameter 181: BATTERY REPORT THRESHOLD
- Parameter 182: TEMPERATURE REPORT THRESHOLD
- Parameter 183: HUMITIDY REPORT THRESHOLD
- Parameter 184: LUMINANCE REPORT THRESHOLD
- Parameter 32: LEVEL OF LOW BATTERY
- Technical Data
- Supported Command Classes
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Hank
Multisensor
SKU: HKZW-MS01
Quickstart
This is a
secure
Alarm Sensor
for
CEPT (Europe).
Please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
2.Add for inclusion (non-security):1) Insert two CR123A batteries.2) Set the
Z-Wave network main controller into learning mode (see Z-Wave network
controller operating manual).3) Triple clicking the Z-button.4) If the
inclusion is successful, the LED will blink less than 5 seconds and then keep
on for 3 seconds, otherwise the LED will blink 5 seconds and then turn off, in
which you need to repeat the process from step 2.Add for inclusion (security):
- Insert two CR123A batteries.2) Set the Z-Wave network main controller into learning mode (see Z-Wave network controller operating manual).3) Press and hold the Z-button for 3 seconds.4) If the inclusion is successful, the LED will blink fast for less than 5 seconds and then keep on for 3 seconds, otherwise the LED will blink fast for 5 seconds and then turn off, in which you need to repeat the process from step 2.
Please refer to the
Manufacturers
Manual for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Multisensor is a universal Z-Wave device. Along with detecting motion the device measures the temperature, humidity and luminance . It can communicate with associated Z-Wave devices, such as Siren, Smart Switch, etc.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Press and hold the Z-button for 20 seconds,Multisensor will send Device_Reset_Locally to the main controller and exclude from the Z-Wave network when the Z-Button is released, this procedure will reset the Sensor to factory default.Please include a request to use the reset procedure only when the primary controller is missing or inoperable.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
2.Add for inclusion (non-security):1) Insert two CR123A batteries.2) Set the Z-Wave network main controller into learning mode (see Z-Wave network controller operating manual).3) Triple clicking the Z-button.4) If the inclusion is successful, the LED will blink less than 5 seconds and then keep on for 3 seconds, otherwise the LED will blink 5 seconds and then turn off, in which you need to repeat the process from step 2.Add for inclusion (security):
- Insert two CR123A batteries.2) Set the Z-Wave network main controller into learning mode (see Z-Wave network controller operating manual).3) Press and hold the Z-button for 3 seconds.4) If the inclusion is successful, the LED will blink fast for less than 5 seconds and then keep on for 3 seconds, otherwise the LED will blink fast for 5 seconds and then turn off, in which you need to repeat the process from step 2.
Exclusion
Remove for exclusion;1.Insert two CR123A batteries.2.Set the Z-Wave network main controller into removing mode (see Z-Wave controller operating manual).3.Triple clicking the Z-button.4.If the removing is successful, the LED will blink slowly for 5 seconds and then turn off, otherwise you need to repeat the process from step 2.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 5| 1. Notification Report.Sensor will send Notification Report to the
associated nodes when Multisensor is removed or/and PIR is triggered.2. Sensor
Multilevel Report.Multisensor will send Sensor Multilevel Report to the
associated nodes at setting interval.3. Battery Report.Multisensor will send
Battery Report when the battery level is low and the battery reports value is
0xFF.4. Device Reset Locally Notification.
---|---|---
2| 5| 1. Basic SetMultisensor will send Basic Set to associated nodes when
the PIR is triggered.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 12: MOTION SENSORS SENSITIVITY.
The higher the value is set, the more sensitive the PIR sensor are.
Size: 1 Byte, Default Value: 8
SettingDescription
1 – 8 | Level 0 to 8 |
---|---|
0 | Disabled |
Parameter 13: MOTION SENSORS BLIND TIME (INSENSITIVITY)
Period of time through which the PIR sensor is blind (insensitive) to
motion. After this time period the PIR sensor will be again able to detect
motion. The longer the insensitivity period, the longer the battery life. If
the sensor is required to detect motion quickly, the time period may be
shortened.
Size: 2 Byte, Default Value: 30
SettingDescription
1 – 60 | blink time is 1 to 60 |
---|
Parameter 14: ENABLE/DISABLE BASIC COMMAND
Multisensor can send BASIC ON/OFF COMMAND CLASS to nodes associated with
group 2.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Disable |
---|---|
1 | Enable |
Parameter 15: BASIC COMMAND VALUE
Multisensor can reverse the BASIC ON/OFF.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Detecting motion: BASIC ON, motion alarm cancellation: BASIC OFF. |
---|---|
1 | Detecting motion: BASIC OFF, motion alarm cancellation: BASIC ON. |
Parameter 170: No.170 SET PARAMETER 171174 TO DEFAULT SETTINGS
Set parameter 171,172,173,174 to default settings
Size: 1 Byte, Default Value: 0
SettingDescription
85 | Set parameter 171,172,173,174 to default settings |
---|
Parameter 171: BATTERY REPORT INTERVAL
The interval of sending battery report to association device (Group
Lifeline). The reportsare sent even if there are no changes in the battery
level.
Size: 4 Byte, Default Value: 1800
SettingDescription
5 – 2678400 | The interval of sending battery report |
---|
Parameter 172: TEMPERATURE REPORT INTERVAL
The interval of sending temperature report to association device (Group
Lifeline). The reportsare sent even if there are no changes in the temperature
level.
Size: 4 Byte, Default Value: 1800
SettingDescription
5 – 2678400 | The interval of sending temperature report |
---|
Parameter 173: HUMIDITY REPORT INTERVAL
The interval of sending Humidity report to association device (Group
Lifeline). The reportsare sent even if there are no changes in the humidity
level.
Size: 4 Byte, Default Value: 1800
SettingDescription
5 – 2678400 | The interval of sending Humidity report |
---|
Parameter 174: LUMINANCE REPORT INTERVAL
The interval of sending luminance report to association device (Group
Lifeline). The reportsare sent even if there are no changes in the luminance
level.
Size: 4 Byte, Default Value: 1800
SettingDescription
5 – 2678400 | The interval of sending luminance report |
---|
Parameter 181: BATTERY REPORT THRESHOLD
The parameter determines the change in battery level resulting in battery
report being sent to the main controller.
Size: 1 Byte, Default Value: 10
SettingDescription
0 – 100| the change in battery level resulting in battery report being sent to
the main controller.
---|---
Parameter 182: TEMPERATURE REPORT THRESHOLD
The parameter determines the change in temperature level resulting in
temperature report being sent to the main controller.(Degrees Celsius)
Size: 1 Byte, Default Value: 20
SettingDescription
0 | reports are not sent |
---|---|
1 – 255 | the change in temperature level resulting in temperature report being |
sent to the main controller.
Parameter 183: HUMITIDY REPORT THRESHOLD
The parameter determines the change in humidity level resulting in humidity
report being sent to the main controller.
Size: 1 Byte, Default Value: 5
SettingDescription
0 | reports are not sent |
---|---|
1 – 255 | the change in humidity level resulting in humidity report being sent |
to the main controller.
Parameter 184: LUMINANCE REPORT THRESHOLD
The parameter determines the change in luminance level resulting in
luminance report being sent to the main controller.
Size: 2 Byte, Default Value: 200
SettingDescription
0 | Reports are not sent |
---|---|
1 – 65535 | the change in luminance level resulting in luminance report being |
sent to the main controller.
Parameter 32: LEVEL OF LOW BATTERY
Define a battery level as the low battery.
Size: 1 Byte, Default Value: 20
SettingDescription
10 – 50 | The low level from 10% to 50% |
---|
Technical Data
Hardware Platform | ZM5101 |
---|---|
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.04 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-17045529 |
Z-Wave Product Id | 0x0208.0x0200.0x0006 |
Sensors | HumidityLuminanceMotion/No Motion (Binary) |
Supported Notification Types | Access Control |
Firmware Updatable | Updatable by Consumer by RF |
Color | White |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Association Grp Info
- Association V2
- Battery
- Configuration
- Device Reset Locally
- Firmware Update Md V2
- Manufacturer Specific V2
- Notification V5
- Powerlevel
- Security
- Sensor Multilevel V5
- Version V2
- Wake Up V2
- Zwaveplus Info V2
Controlled Command Classes
- Basic
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)