Jandy JHCBUB TruFit LED Pool Bubbler with Pressure Check Technology Owner’s Manual
- June 5, 2024
- Jandy
Table of Contents
- Jandy JHCBUB TruFit LED Pool Bubbler with Pressure Check Technology
- Important Safety Instructions
- Installing
- Package Contents
- Bubbler Installation Guidelines
- Large Construction Cap and Adjustable Sleeve
- Winterizing
- Troubleshooting
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Jandy JHCBUB TruFit LED Pool Bubbler with Pressure Check Technology
WARNING
FOR YOUR SAFETY
This product must be installed and serviced by a contractor who is licensed
and qualified in pool equipment by the jurisdiction in which the product will
be installed where such state or local requirements exist. The maintainer must
be a professional with sufficient experience in pool equipment installation
and maintenance so that all of the instructions in this manual can be followed
exactly. Before installing this product, read and follow all warning notices
and instructions that accompany this product. Failure to follow warning
notices and instructions may result in property damage, personal injury, or
death. Improper installation and/or operation may void the warranty.
Improper installation and/or operation can create unwanted electrical hazards which can cause serious injury, property damage, or death.
ATTENTION INSTALLER
This manual contains important information about the installation, operation,
and safe use of this product. This information should be given to the
owner/operator of this equipment.
Important Safety Instructions
IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS READ AND FOLLOW ALL INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
DANGER
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. This underwater light must be
installed by a licensed or certified electrician in accordance with the
National Electrical Code® and applicable local codes and ordinances. In
Canada, the Canadian Electrical Code and all applicable local codes and
ordinances must be adhered to. Improper installation will create an electrical
hazard, which could result in death or serious injury to pool or spa users,
installers, or others due to electrical shock, and may also cause damage to
property. Read and follow the specific instructions below.
WARNING
Before installing this underwater lighted bubbler, read and follow all
warning notices and instructions accompanying this light. Failure to follow
safety warnings and instructions can result in severe injury, death, or
property damage. Visit www.jandy.com for additional
free copies of these instructions or call Zodiac Technical Support at
800.822.7933 (U.S.) or 888.647.4004 (Canada)
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
which could result in serious injury or death. The Jandy® Pro Series Nicheless
LED Lights are only available for 12-volt AC power. For supply connection, use
only an isolating low voltage power supply with ungrounded output, evaluated
and listed by an NRTL for swimming pool use.
ATTENTION INSTALLER
This manual contains important information about the installation,
operation and safe use of this product. This information should be given to
the owner/operator of this equipment.
Installing
The Bubbler Housing is pre-assembled for easy connection to a water supply line (1) and a conduit connection for the Jandy HydroCool Nicheless Pool Light cord to run through.
NOTE:
Be sure to read the entire Owner’s Manual completely and carefully to
assure you understand the system before you start your installation.
NOTE:
- Do NOT use pipe dope for installation.
- Install plumbing before any electrical wiring.
Installation Preparations
The conduit for the low voltage supply cord (12Vac) can be run directly to a
Junction Box where Light(s) connections and Low Voltage wires from the
Transformer (sized correctly) are made. To reduce the risk of bad connections
and unwanted voltage drops, all Power Cords on lights should run directly to
the Low Voltage Transformer. To ensure maximum safety, only use a low voltage
that is listed or certified by a Nationally Recognized Testing Laboratory
(NRTL) as compliant with UL 379, Standard for Power Units for Fountain,
Swimming Pool, and Spa Luminaires. The TruFit Bubbler is designed so that the
lens of the tube is approximately 4”- 8” (10-20 cm) underwater, but can be
deeper as long as the water supply can be increased. Keep in mind that the
deeper the lens is underwater the less lighting effect will be above the
water. Water flow should be adjusted to the desired plume while Jandy®
HydroCool Nicheless Pool Light is set to the desired color mode. Use the table
below to determine the approximate plume height for each lens.
1/2” LENS PLUME HEIGHT
Water Depth| 2”| 4”| 6”| 8”| 10”| 12”
5 GPM| 9”| 6.5”| 4”| | |
10 GPM| 22.5”| 12”| 8”| 7”| 4.5”| 4”
15 GPM| 59”| 28”| 16.5”| 10.5”| 8”| 7.5”
20 GPM| | 49”| 28”| 16”| 12.5”| 11.5”
25 GPM| | | 45.5”| 27.5”| 18”| 16”
3/4” LENS PLUME HEIGHT
Water Depth| 2”| 4”| 6”| 8”| 10”| 12”
10 GPM| 8”| 6”| 4.5”| | |
15 GPM| 15.5”| 10.5”| 7.5”| 6”| 5”| 4.5”
20 GPM| 27”| 17”| 11”| 9”| 7.5”| 6.5”
25 GPM| 41”| 26.5”| 16.5”| 12.5”| 11”| 8”
30 GPM| 61”| 36”| 23”| 16.5”| 13”| 11”
35 GPM| | 49”| 34”| 22.5”| 17”| 14.5”
40 GPM| | 64”| 49”| 30.5”| 22”| 17.5”
45 GPM| | | 61”| 39”| 27”| 21”
50 GPM| | | | 51”| 34.5”| 26.5”
Package Contents
- Jandy® Bubbler Body
- Small Construction Cover
- Large Construction Cover
- Lens x 2 (3/4” & 1/2”)
- Lens O-Ring
- Diffuser
- Adjustable Sleeve (4 in / 10 cm diameter)
The TruFitTM Bubbler body comes with the Large Construction Cover pre-
assembled and ready to pressure test.
Inside the TruFit Bubbler Body – a Small Construction Cover has already been
installed. Do not remove this until the Bubbler Body is ready to have the
light installed.
NOTE:
The TruFit Bubbler is designed for gunite pools; fiberglass and vinyl pool
installation are available with an accessory kit. (SKU/Model # JHCBUB-V).
Bubbler Installation Guidelines
Listed Junction Box certified for pool/spa luminaires, or Listed Low Voltage Transformer certified for pool/spa luminaires and direct conduit connection to wet-niche or no-niche luminaires.
Large Construction Cap and Adjustable Sleeve
- The top of the cap (A) indicates the maximum finish height of the bubbler. There is 1″ of downward adjustability.
- The lower indicator on the cap (B) indicates the minimum finish height of the bubbler. This uses the full 1″ of downward adjustability.
The TruFitTM Bubbler has an adjustable sleeve that can easily be cut to fit the desired level. The large construction cap is designed to be a guide for showing the range of adjustability.
Bubbler Housing Installation Level
Installing the TruFit TM Bubbler Housing
-
The TruFit Bubbler is designed to be installed during the gunite phase of the pool building.
-
Two conduits should be run to the Bubbler body:
- 1.5” PVC Pipe for water supply and
- 1” conduit for Pool Light Power Cord.
NOTE: Do NOT use 90-degree fittings. Only 45 degrees or sweep elbows.
-
The 1.5” PVC pipe supplying the water to the Bubbler should have a gate valve or ball valve installed to adjust the water supply flow to create desired water/lighting effect.
-
Conduit for the TruFit Bubbler power cord must run from the bubbler directly to a listed Junction Box certified for pool/spa luminaires, or a Listed Low Voltage Transformer certified for pool/spa luminaires and direct conduit connection to wet-niche or no-niche luminaires.
-
With the large construction cap on, install the Bubbler Housing onto the pipe so that the disired finished surface is above the lower indicator (B) and below the top of the cap (A). See figure 4
Important: After gunite, you need to “cove” around the TruFit Bubbler Housing. This is so that the Large Construction Cover can be removed and the adjustable sleeve can be installed and trimmed to be flush with the interior surface. -
Dig a cove around the top of the TruFit Bubbler Housing.
-
Trim Adjustable Sleeve to be flush with the interior surface.
NOTE: Threaded inserts on the adjustable sleeve are only used for vinyl/ fiberglass installations. -
Install the Small Construction Cover before plastering. This ensures the threads remain clean and no debris falls into the Bubbler Housing.
-
Backfill the “cove” area around the Bubbler Housing. After plastering, remove the Small Construction Cover.
NOTE: Leave the O-ring in the bubbler body when removing the Small Construction Cover to seal the pool light when it is installed. -
Install the Jandy® HydroCool Nicheless Pool Light (see Section 2.4).
-
Install the diffuser into the adjustable sleeve. Rotate until the cutouts on the diffuser align with the pins on the adjustable sleeve.
-
Select the lens for the desired water effect. Wrap the lens O-Ring around the lens groove. Install the lens into the adjustable sleeve and rotate the lens until it is secured.
Plumbing Multiple TruFitTM Bubblers
When installing multiple bubblers it is advised that a looped manifold system
be implemented to provide independent water flow control to each of the
bubblers on the system. See Figure 1.
- Plumb an adjustable ball or gate valve to supply flow to the manifold assembly.
- If necessary install reducer bushings to bring the supply lines to each bubbler down to the required 1.5” supply size.
- Plumb an adjustable ball or gate valve on each branch of the manifold.
- Use the individual ball valves to adjust the plume height on each of the bubblers to your preference.
Looped Manifold Plumbing
LED Light Installation
The Jandy TruFitTM Bubbler with Pressure Check Technology is designed to be
fitted with a Jandy® HydroCool Nicheless Pool Light. Once the pressure tests
have been completed and the Small Construction Cover has been removed, you are
ready to install the Jandy HydroCool Nicheless Light into the Bubbler Housing.
- Feed the power cable through the housing and conduit to the power source. Allow 18”-24” slack for the service loop.
- Place the Light into the Bubbler and tighten it into the threaded housing.
- See the Jandy HydroCool Nicheless light Owner’s Manual for light installation instructions.
Winterizing
Do not keep the winter water level at the level of the light. Make certain that the water level is left at least 4” or more above or below the light depending on the pool’s other winterization needs. Consult a Local Swimming Pool Professional for proper winterization. At NO TIME should there be water removed from the pool without checking groundwater tables?
Troubleshooting
Use the troubleshooting information in the following table for suggestions.
Symptom | Problem | Corrective Action |
---|---|---|
All lights fail to illuminate | Lights are not receiving power | Check 120VAC |
power supply into the transformer. Check for 12VAC output at the transformer.
If 120 volts were used in the installation, damage may result and will not be
covered under warranty.
One or more lights are dim, blinking, or not working| Poor connection or
improper wire gauge| Separate each light and independently wire 12V to the
single light only. Repeat this process on each light. If the junction box is
being used, check for the proper connection of the light cord. Verify that the
correct wire gauge is being used between the transformer and junction box.
Colored lights out of synch| Improper voltage supply or poor connection to the
light| Verify that proper wire connections are being achieved for the lights
that are out of synch. Reset all the lights to white by turning lights OFF for
five (5) seconds, then turning ON.
Zodiac Pool Systems LLC
2882 Whiptail Loop # 100 Carlsbad, CA 92010 1.800.822.7933 | Jandy.com
Zodiac Pool Systems Canada, Inc.
3365 Mainway, Unit 2 Burlington ON L7M 1A6 1.888.647.4004 | Jandy.ca. ©2021
Zodiac Pool Systems LLC. All rights reserved. ZODIAC® is a registered
trademark of Zodiac International, S.A.S.U., used under license. All other
trademarks are the property of their respective owners. H0666000 REVD.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>