BN-LINK BNQ-U40N Plug In Power Energy Meter Instruction Manual

June 5, 2024
BN-LINK

BN-LINK BNQ-U40N Plug In Power Energy Meter

  • VOL: instant voltage AmP: instant amperage
  • WATT: instant active power
  • PF : power factor
  • Kwh : cumulative energy consumption
  • Hz : instant frequency
  • VA : instant apparent power

BUTTON DESCRIPTION

  • FUNCTION : press to switch between different setting and display pages
  • SELECT : press to select
  • ADJ : press to adjust values
  • SET : press to enter a setting page
  • R : reset

OPERATING INSTRUCTIONS

SET UNIT COST

  1. Press SET to enter the unit cost setting page.
  2. Icon COST/KWh and numbers 88.88 will show with the 8 on centile flashing. Use ADJ to adjust the flashing number (cycles from Oto 9) and press SELECT to confirm. The number on decile will now flash. use ADJ to adjust and SELECT to confirm. Repeat above steps till all four numbers are set as desired. In this setting page, all four numbers will be displayed even if the number on decade is 0.
  3. Press FUNCTION to quit.

INFORMATION DISPLAY

  1. When energized for the first time, LCD will show cumulative cost, Display range: 0.00-9999.99.
  2. Press FUNCTION to display unit cost COST/KWh. Display range: 0.00-99.99.
  3. Press FUNCTION to display cumulative power consumption in kWh with display range 0.00-9999.99.
  4. Press FUNCTION to display instant active power. (Accuracy at 0.1 with active power not exceeding l 00 WATT and accuracy at l with active power exceeding l 00 WATT). Display range: 0.5-1875.
  5. Press FUNCTION to display instant apparent power, (Accuracy at 0.1 with apparent power not exceeding l 00 VA and accuracy at l with active power exceeding l 00 VA), Display range: 0.5-1875,
  6. Press FUNCTION to display instant voltage, e.g.: 125.0.
  7.  Press FUNCTION to display instant amperage with display range 0.00-15.00.
  8. Press FUNCTION to display grid frequency, e.g.: 60.0.
  9. Press FUNCTION to display power factor with display range 0.00- l .00.
  10. Press FUNCTIONto display COST as described in 2. l.

SPECIAL FUNCTION

  1. Press R to reset the system. COST value will be displayed after reset.
  2. Set or clear kWh value. When kWh value reaches 9999.99, press SET twice to enter the kWh setting page. The LCD will display 9999. 99 with the 9 on centile flashing. Use ADJ to adjust and SELECT to confirm. To clear kWh value. adjust all numbers to O and confirm. COST value will also be cleared if kWh value is cleared.
  3. Press FUNCTION till COST or KWH displays. Press and hold ADJ for 3 seconds to reset COST or KWH to 0.00

TECHNICAL SPECIFICATIONS

  • VOLTAGE RATING: 125 VAC, 60 Hz.
  • INSTANT ACTIVE POWER DISPLAY RANGE: 0.5
  • WATT – 1875 WATT. UNIT COST RANGE: 0.Dl-99.99

Do not exceed electrical ratings

FORMATION DISPLAY:

  • Voltage: VOL;
  • Frequency: Hz:
  • Instant active power: WATT;
  • Instant apparent power: VA’,
  • Power factor: PF;
  • Unit cost: COST/KWh;
  • Power consumption: KWh;
  • Cost: COST;

BN-LINK INC.
12991 Leffingwell Avenue, Santa Fe Springs Customer Service Assistance: 1.909.592.1881 E-mail: support@bn-link.com http://www.bn-link.com
Hours: 9AM – 5PM PST, Mon – Fri Designed in California Made in China