Spacetronik SPD-D1M1 Video Intercom System User Manual

June 5, 2024
Spacetronik

Spacetronik SPD-D1M1 Video Intercom System logo

Spacetronik SPD-D1M1 Video Intercom System

Part Names

Outdoor stationSpacetronik SPD-D1M1 Video Intercom System fig
1

No. Name & description
1 Infrared induction
2 Green light on when unlocking
3 Blue light on when calling
4 Fill-in flash and light sensor
5 Camera
6 Speaker
7 IC card swiping area
8 Touch screen
9 Microphone
10 TF card port

Parts and Functions

Mounting

Spacetronik SPD-D1M1 Video Intercom System fig
3

  • Drill a hole and attach the rain cover to it
  • Attach the unit to the rain cover correctlly
  • The last view for all mounting

Terminal Description

  • BUS: (L1, L2) non-polarity bus line
  • CAM: Extra camera connection port
  • LOCK: Electronic lock connection port
  • VOL: Volume adjustor
  • DIP: DIP switches for system configurations.
  • SIP1: Door lock jumper

Multi door station

Spacetronik SPD-D1M1 Video Intercom System fig
5Spacetronik SPD-D1M1 Video Intercom System fig
6

When monitor quantity < 20

Cable Usage A B C
Parallel cable 2×0.75mm2 60 60 30
Parallel cable 2x1mm 2 80 80 40

When monitor quantity > 20

Cable Usage A B C
Parallel cable 2x1mm 2 60 60 30
Parallel cable 2×1.5mm2 80 80 40

Operation Screens

Home page is the first page when outdoor station stand-by. When outdoor station standby to start, there is no image show on the screen, you need to click any places of the screen, outdoor station will be activated, home page is the first page after outdoor station activated. Spacetronik SPD-D1M1
Video Intercom System fig 7

Home pageSpacetronik SPD-D1M1 Video Intercom System fig
8

No. Description

1

| Digital call screen
2| Name list call screen


3

| Searching screen


4

| Unlocking screen
5| Backspace key


6

| Calling key


7

| Language choice

Communication Screen

The following screen is displayed when calling a person to visit.

No. Description
1 Shows the information of the destination station
2 Indicates outgoing call is being made
3 Exit calling
4 Decrease ringtone volume
5 Increase ringtone volume

After answer the call, talk with indoor monitor

No.|
---|---
1| Indicates in communication
2| Decrease calling volume
3| Increase calling volume
4| Exit key

Calling a Person to Visit

Calling using the keypad

  1. Enter the “Unit Number”
    • Use to delete incorrectly entered Unit Numbers Spacetronik SPD-D1M1 Video Intercom System fig 12
  2. Tap
    • Calling key
  3. Speak with the other party.
    • Tap to end communication.

Calling using the Direct Call List

  1. Tap the name to visit
  2. Speak with the other party.
  3. Tap to end communication.

Calling by searching for a name

Use the keyboard to search for a resident by name.
Call and communicate with the person to visit by selecting from the search results.

  1. Enter the resident’s name
    Use to delete incorrectly entered name. Spacetronik SPD-D1M1 Video Intercom
System fig 12

  2. Tap the name to visit

  3. Speak with the other party Tap to end communication

Unlocking the door

Releasing by entering Access Code

An electric lock can be released by entering Access Code using the keypad.

  1. Enter access code. Spacetronik SPD-D1M1 Video Intercom System fig 20

Note The door release duration varies depending on the settings. The door released icon will be displayed for approximately 3 seconds regardless of the set duration. Input 4 bit unlocking password(default 8888)

Release the door using access control credentials (cards, tabs, tags,

mobile)

Door release can be activated by passing an access control credential.

  1. Hold the access control credential Spacetronik SPD-D1M1 Video Intercom System fig 21
  • The unlock tone or audio guidance may play when the door is released.
  • The door released icon will be displayed for approximately 3 seconds.
  • If the proximity key is authenticated, the Card reader indicator will turn ON (green) for approximately 1 seconds.

Note

  • The door release duration varies depending on the access  control system settings.
  • The door released icon will be displayed for approximately 3 seconds regardless of the set duration.
  • The door released icon may not be displayed.
  • Access control credentials are registered on the access control system. Refer to the manual of the access control system for details.

Settings and Adjustments

Selecting the Display Language
Visitors may temporarily select a different display language if needed.

  1. Tap .
  2. Tap the language to display
    • Tap to return to the previous screen.
      The setting will be changed.

Enter system setting screens Long press screen 2 seconds, input management password(default 1234)

No. Description
1 Volume Adjustment
2 Function Setting

3

| Password Setting


4

| Interface Setting
5| Restore To Original Factory Settings


6

| Language Setting


7

| IC Operation


8

| Updata System or Format SD Card


9

| Return To Main Interface

Setting screens

  1. Volume adjustment screen Spacetronik SPD-D1M1 Video Intercom System fig 28

  2. Function setting screen Spacetronik SPD-D1M1 Video Intercom System fig 29

  3. Password setting screen Spacetronik SPD-D1M1 Video Intercom System fig 30

  4. Interface setting Spacetronik SPD-D1M1 Video Intercom System fig 31

  5. Restore to the original factory settings
    Input the management password(default 1234), restore to the original factory settings.

  6. Volume adjustment screen Spacetronik SPD-D1M1 Video Intercom System fig 32

  7. Program update
    Put the program into SD card, press Download key, update the program.
    After finished the update will restart automatically.Press Format SD Card key,format SD card.

  8. Error screen troubleshooting Spacetronik SPD-D1M1 Video Intercom System fig 33

  9. Modify the name in calling name list

    • Ticking to make the name list can be modified.
    • Choose the name list you want to modify Spacetronik SPD-D1M1 Video Intercom System fig 34
    • Re-input the name, after modified press enter key Spacetronik SPD-D1M1 Video Intercom System fig 35
    • Non-ticking to make the name list can be modified

SPECIFICATIONS

  • Power supply: DC 24V
  • Power Consumption: 1W in standby, 5W in working
  • Unlock Power output: 12Vdc, 250mA
  • Unlock timing: 0-25s
  • Working Temperature: -20°C~+55°C

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>