Hanwha Techwin SECL-IR940-POEPL-M Infrared and White Light LED Illuminators Installation Guide

June 5, 2024
Hanwha Techwin

Clarius ® PLUS
Infrared & White Light LED Illuminators

SECL-IR850-DC-S
SECL-IR850-DC-M
SECL-IR850-DC-L
SECL-IR850-DC-XL
SELL-IR850-POE-S
SECL-IR850-POEPL-M
SECL-IR940-DC-S
SECL-IR940-DC-M
SECL-IR940-DC-L| SECL-IR940-DC-XL
SECL-IR940-POE-S
SECL-IR940-POEPL-M
SECL-WL928-DC-S
SECL-WL2300-DC-M
SECL-WL2784-DC-L
SECL-WL3712-DC-XL
SECL-WL928-POE-S
SECL-WL1856-POEPL-M
---|---

DESCRIPTION

A complete range of Infra-Red and White-Light illuminators for CCTV, the visible and Invisible range feature state-of-the-art technology and installation-friendly design.

  •  Energy-efficient, low voltage operation for quick and easy installation
  • Dual-Core ® LED technology with advanced electronic control circuitry delivers improved thermal management, long life, and a low cost of ownership.
  • CleanLITE ® self-cleaning lens coating technology
  • Semi covert, covert, and visible White-Light versions
  • Built-in photocell
  • Easy integration with day/night cameras with relay contacts indicating if the built-in photocell has activated the illuminator
  • Remote telemetry input
  • Easy access to power and photocell adjust
  • The pressure equalization vent prevents thermal expansion and pressure cycling
  • Interchangeable lens diffuse technology

SPECIFICATION

Electronics| High-efficiency surface mount high power LEDs with advanced current limited integral control circuitry
---|---
Beam Angles| 10º, 30°, 60° & 95°
Lens/Beam Pattern| The illuminator should be matched to the scene and the camera lens focal length
Wavelength| 850nm and visible white light 940nm and visible white light
Expected Life| 10 years
Consumption| SECL-IRxxx-xx-S/SECL-WLxxx-xx-S15W
SECL-IRxxx-xx-M/SECL-WLxxx-xx-M26W
SECL-IRxxx-xx-L/SECL-WLxxx-xx-L39W
SECL-IRxxx-xx-XL/SECL-WLxxx-xx-XL 52W
Input Voltage| 12-32V DC or 24V AC 50-60 Hz
Operating Temp| -50° to 50° (-58° to 122°F)
Environmental| IP66. Suitable for indoor and outdoor use
Construction| Robust high quality aluminum extrusion
Front Window| Polycarbonate high transmittance protection (vandal-proof) with
CleanLITE ® technology
Dimensions| SECL-IRxxx-xx-S/SECL-WLxxx-xx-S 68 x 110 x 78mm
SECL-IRxxx-xx-M/SECL-WLxxx-xx-M 114 x 110 x 78mm
SECL-IRxxx-xx-L/SECL-WLxxx-xx-L 161 x 110 x 78mm
SECL-IRxxx-xx-XL/SECL-WLxxx-xx-XL 213 x 110 x 78mm
Weight| SECL-IRxxx-xx-S/SECL-WLxxx-xx-S 750g (1.6lbs)
SECL-IRxxx-xx-M/SECL-WLxxx-xx-M 1.05kg (2.3lbs)
SECL-IRxxx-xx-L/SECL-WLxxx-xx-L 1.35kg (3lbs)
SECL-IRxxx-xx-XL/SECL-WLxxx-xx-XL 1.75kg (3.9lbs)
Power Cable| 3m (9ft). Other lengths available to order
Mount| Black powder-coated stainless steel wall mount. Adjustable via M6 Allen Key (included)

INSTALLATION

Note:

  •  Installation should be done by skilled personnel or under the supervision of such personnel
  • The illuminator is low voltage 12-32V DC or 24V AC.
  • Only to be installed n restricted Access Areas.
  • Terminal block not included. Installation may require advice from a qualified person.

Optimum results are achieved by setting up at night and viewing the results on a monitor.

  1. Attach the illuminator mount to the pan/tilt unit, wall, or camera housing. Using stainless steel fixings suitable for the relevant application.

  2. connect the lamp to a suitable (SELV) low voltage supply. Ensure that the polarity is correct.

  3. Commission the mains supply, camera, and monitoring equipment.

  4. Select the diffuser angle sheet required from the Clarius box (if required). To position, the required diffuser sheet, insert the tool included in the slot at the bottom of the cover and prise upwards slowly. Repeat at the opposite end and carefully remove the cover. Remove the baking sheet from the two adhesive discs and secure the required diffuser in position. Finally, firmly lip the lens cover back into place.

  5. Adjust the pan angle of the illuminator to match the camera’s field of view.

  6. Adjust the vertical alignment by loosening the side bolts (one on each side of the main body) to maximize the results.

  7. Tilt the lamp downwards until the rear part if the required field of view is saturated with light, as viewed on the monitor.

  8. SLOWLY and GRADUALLY tilt the lamp upwards until the for part of the required field of view is illuminated correctly on the monitor.

POWER AND CONTROL CABLE CONNECTIONS

Use suitable IP66-rated enclosure and terminal block for connection conforming to EN60998-2-1 or EN60998-2-2
Recommended PSU
SECL-IRxxx-xx-S/SECL-IRxxx-xx-M , SECL-WLxxx-xx-S/SECL-WLxxx-xx-M : 24V 30W (SECL-PSU-30W)
SECL-IRxxx-xx-L/SECL-IRxxx-xx-XL , SECL-WLxxx-xx-L/SECL-WLxxx-xx-XL : 24V 60W (SECL-PSU-60W)
Use only with a Class 2 power supply.
SELV Power supply should be approved to relevant EN Safety standards.
SELV Power supply should be used with devices to protect against short circuits and overload.
Remote Switching
The Illuminator may be activated remotely by a volt-free contact latched across the telemetry wires (see Diagram above).
Photocell following contact
Volt-free relay contact-normally open (day) to normally closed (night). See the diagram above.

CERTIFICATIONS

This product complies with the European Directive 2014/30/EU
Electromagnetic Compatibility and 2014/35/EU Low Voltage Directive by  meeting the following standards:

CE-EMC| EN 61547
EN 55015
EN 62493
EN 50130-4| (Lighting-Immunity)
(Lighting-Emission)
(Lighting -EMF)
(Alarm-EMC)
---|---|---
CE-LVD| EN 60598-1
EN 60598-2-1| (Luminaires-General) (Luminaires)
Safety| EN 62471 Risk
group 2| (LED safety)
Environmental| IEC/EN 60529
EN50130-5| IP66 (Alarm-environmental)
USA| FCC, Class B
AUS| RCM (AS/NZS CISPR 22 Class B)
RoHS:| Restriction of Hazardous Substances European directive 202/95/EC
Certifications|
WEEK:| Waste Electrical & Electronic Equipment European directive 202/96/EC

This symbol on the product means that the electrical and/or electronic equipment to which it relates should be disposed of at the end of life separately from domestic household waste.
There are separate collection systems for recycling in the EU. For more information please contact the Local Authority or supplier of the product.

Power Adjust
To adjust the power, first, unscrew the sealing cap then adjust the power potentiometer clockwise to increase the power and counterclockwise to turn it down. The unit is factory set to maximum output.
Photocell
The photocell is designed to automatically switch the lamps on at dusk and turn off at dawn. A high degree of hysteresis is incorporated to void on/off switching in marginal conditions. The unit is factory set at approximately 30 Lux On and 70 Lux Off, but can be adjusted.
Photocell Sensitivity
To adjust the photocell sensitivity first remove the sealing cap, then adjust the potentiometer to turn the lamp on when lighting conditions are lighter or darker. Adjust the counterclockwise to make the lamp turn on when it is lighted and clockwise when it’s darker.
Disabling the photocell
To disable the photocell, adjust the sensitivity fully counterclockwise. This will make the lamp turn on at all times.

Safety Warning

  • When the lamp is running, it is hot to touch. before touching switch off the illuminator and allow
  • to cool for a minimum of 10 minutes.
  • The illuminator should be positioned so that prolonged starring into the illuminator at a
  • A distance closed to 1m is not expected.
  • The light source of this illuminator is not replaceable, when the light source reaches its end of
  • life the whole illuminator should be replaced.
  • If the flexible power cord of the illuminator is damaged it should be exclusively replaced by an authorized service agent.
  • This equipment is not suitable for use in locations where children are likely to be present.

PoE Models
The Clarius PoE/PoE+ series illuminators are powered by Power over Ethernet (PoE) via a network cable connector to a PoE IEEE802af/IEEE802at compliant switch.
The power consumption of the illuminators complies with PoE IEEE802af and IEEE802at.
These illuminators are not supplied with a power cord. Instead, they are supplied with a 2.5m (8’) long network cable. At the end of the network, cable is a female RJ45 Cat5e compliant connector with an IP68-rated cover.
The IP68-rated cover is supplied with the illuminator. Follow the instructions supplied with the cover on how to attach if to the male Cat5e network cable.
ENSURE THAT THE IP68-RATED COVER IS CORRECTLY FITTED AND ATTACHED TO THE NETWORK CABLE. IF THIS IS NOT FITTED CORRECTLY MOISTURE CAN GET INTO THE CONNECTOR AND MAY CAUSE THE UNIT TO MALFUNCTION. THIS WOULD VOID THE WARRANTY ON THE PRODUCT.

Trouble Shooting

Ensure all tests are undertaken by a qualified, trained engineer and ensure safe working practices are followed at all times.
Step 1 : Basics

  • Check power connection
  • Ensure power is 12-32V DC / 24V AC 50-60Hz
  • Check the photocell is working – cover photocell, the light should turn on
  • Ensure power supply is suitably rated to the product – check the specifications

Step 2 : Lamp Test

  • Check current draw of the lamp corresponds to the specification
  • Check the current of the lamp – see instructions for correct current settings

To check lamp current remove +ve (red) lead from the power supply and connect a multimeter (set to 10A) in line with the lamp. (One lead of multimeter in common (COM) other lead into 10A socket of multimeter; set multimeter to read Amps). Refer to PSI Specifications for correct current settings.

Step 3: Set up Camera, lens, and Illumination

  • Check alignment of the lamp
  • Check camera lens- fully open at night and set correctly
  • Check model number to performance specification to ensure the required distance is achievable

Step 4: Call for further assistance
If the lamp is still not delivering the required performance, please contact Technical Support for further assistance

Note down:

  • The model number and serial number of the illuminator
  • Camera make and model
  • Lens make and model

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Hanwha Techwin User Manuals

Related Manuals