Congratulations on purchasing the Baintech Ultimate Off-Grid Board, the all- in-one solution for your off-grid adventures! Our ultimate Off-Grid Board is Powered by Victron Energy products and features DC-DC Charging, Solar Charging, and shore power for your battery bank. It also features an inverter for 240v appliances and air conditioning. All of this is protected with circuit breakers, fuses, and low-voltage cut-outs. The entire system is then controlled and monitored through either the Touch Panel or through your Smartphone via Bluetooth.
This is a simple Quick Start guide to get your system installed and to get you adventuring as soon as possible.

Bainbridge 3000 Escap Baintech Ultimate Off-Grid Board - Anderson Connection
Summary

**** 1300 224 683
salesobaintech.com.au
baintech.com.au

Step 1 – Mounting the board

The first step is mounting the Power Board in the desired location in your canopy/camper. You will need to drill your own mounting points on the board, we have left space on each of the 4 corners to do so (red dots on the diagram below). Then securely mount the board in the desired location. The board can only be mounted vertically or flat on the ground, under NO circumstances should the board be mounted facing down.

Bainbridge 3000 Escap Baintech Ultimate Off-Grid Board - Step
1

Step 2 – Mounting and Connecting the Victron Multiplus

The next step is mounting and then connecting your Victron Multiplus to the Power Board. The Multiplus should be mounted as per specifications provided in the provided Multiplus Manual, which is either flat on the ground or vertical with the use of the provided mounting bracket. Once mounted, you can then connect the board to the Multiplus. This can be done through the supplied cables, with the red cable labeled “To Inverter +” to be connected to the positive of Multiplus, and the black cable labeled “To Inverter -” should be connected to the negative of the Multiplus. It should look something like the following diagram.Bainbridge 3000 Escap Baintech Ultimate Off-Grid Board -
Step 2

To connect the AC In & Out to the unit, please consult a licensed electrician. UNDER NO CIRCUMSTANCES SHOULD THE AC IN & OUT BE CONNECTED BY UNQUALIFIED PERSONNEL, ONLY BY A LICENSED ELECTRICIAN.

Step 3 – Connect the Baintech 110aH Lithium batteries in Parallel

The next step is to run your supplied Baintech Lithium Batteries in parallel. This can be done by connecting the supplied cables, with the red cables labeled “Parallel +” to be connected to the positive terminals of all 3 batteries, and the black cables labeled “Parallel -” should be connected to the negative terminals of all 3 batteries. (Ensure the black negative cables are connected LAST). Once the batteries are connected in parallel, mount the batteries to the floor in your desired spot. Bainbridge 3000 Escap Baintech
Ultimate Off-Grid Board - Step 3

Step 4 – Connect the batteries to the Baintech Ultimate Off-Grid Board

The next step is to connect your batteries to the board. This can be done by connecting the supplied cables, with the red cable labeled “Battery +” to be connected to the positive terminal on the left of the battery bank, and the black cables labeled “Battery -” should be connected to the negative terminals on the right side of the battery bank.  Ensure the black negative cables are connected LAST). Once the batteries are connected to the board, you can turn the battery switch on and you’re all set up to go on your next outdoor adventure!!

Bainbridge 3000 Escap Baintech Ultimate Off-Grid Board - Step
4

Anderson Connection Summary

Bainbridge 3000 Escap Baintech Ultimate Off-Grid Board

In the above picture, the round zoomed-in photo of the Anderson plugs has a detailed description of what each Anderson plug is for
Solar (Red Anderson): to connect the system via your unregulated solar input
DC-DC (Blue Anderson): to connect the system via your Vehicles Starter Battery /AlternatorNon-critical (Single Grey Anderson): this is for your accessories that don’t matter if they lose power e.g. 12v TV or certain lighting.
Critical (Double Grey Anderson): This is for accessories that need to have power all the time e.g. fridges, CPAP machines, emergency lighting

Links to product manuals

Victron SmartSolar 100/50 MPPT:
https://www.victronenergy.com/upload/documents/Manual_SmartSolar_MPPT_10030__100-50 /MPPT_solar_charger_manual-en.pdf
Victron Orion-TR Smart 12/12-30 DC-DC Charger:
https://www.victronenergy.com/upload/documents/Orion-Tr_Smart_DC- DC_Charger__Isolated/Orion-Tr_Smart_DC-DC_Charger-en.pdf
Victron Cerbo GX:
https://www.victronenergy.com/upload/documents/Cerbo_GX/GX_Device_Manualen.pdf
Victron GX Tank:
https://www.victronenergy.com/upload/documents/GX_Tank_140/GX_Tank_140-en.pdf
Victron Smart  BatteryProtect:
https://www.victronenergy.com/upload/documents/Manual-Smart-Battery-Protect- 12V24V-65-A-100-A–220-A-EN-NL-FR-SV-DE-PT-ES-IT- TR.pdf
Victron Multiplus-II 3000VA:
https://www.victronenergy.com/upload/documents/MultiPlus-II_230V /MultiPlusII___Quattro-II_120V-230V-en.pdf
Victron SmartShunt:
https://www.victronenergy.com/upload/documents/SmartShunt /Manual_BMV_and_SmartShunt-en.pdf

Ph 07 3348 8082
E[email protected]
‘The Power Systems Experts’
www.baintech.com.au

Documents / Resources

| Bainbridge 3000 Escap Baintech Ultimate Off-Grid Board [pdf] User Guide
3000 Escap Baintech Ultimate Off-Grid Board, 3000 Escap, Baintech Ultimate Off-Grid Board, Ultimate Off-Grid Board, Off-Grid Board, Board
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Bainbridge User Manuals

Related Manuals