BG ELECTRICAL NPR70W Nexus Metal Switched Socket Cooker Unit Instruction Manual

June 5, 2024
BG Electrical

Wiring Accessories
45A DP Switch and Cooker Control Unit

Safety Warning

For your safety, this product must be installed in accordance with local Building Regulations. If in any doubt, or where required by the law, consult a competent person who is registered with an electrical self-certification scheme. Further information is available online or from your Local Authority. Please read carefully and use in accordance with these safety wiring instructions. Before commencing any electrical work ensure the supply is switched off at the mains. Either by switching off the consumer unit or by removing the appropriate fuse or turning off MCB (trip). Wiring should be in accordance with the latest edition of the IET Regulations (BS 7671). To prevent fire hazards always use cable of the correct rating & type for the application.
Warning do not exceed the load rating of this device as stated on the rear of the product.
This product must be connected to a separate 45A protected radial circuit. These products have no cable entry and should only be used for “hard” wired installations.
Wire Identification – Twin & Earth Cable
Note – As of 1st April 2004 new color codes for hard-wire installations were introduced.
EARTH = Green/Yellow Sleeving
NEUTRAL = Black (pre Apr 04) / Blue (after Apr 04)
LIVE = Red (pre Apr 04)/ Brown (after Apr 04)

Wiring Instructions

1. Power Off
Before commencing work always isolate the power at the consumer unit / fuse box. *Note – If your installation uses a four-lug metal mounting box, remove the – top and bottom lugs or bend fully back.
2a. Replacing an existing accessory

  1. Unscrew the accessory from the wall/mounting box.
  2. Note the cable connections: The illustration shows 1 wire of each color connected to each terminal. There should be an additional connection between the mounting box earth terminal and the accessory earth terminal.
  3. Unscrew each terminal to release the wire.

2b. New installation

  1. Install mounting box (metal or molded) for either flush or surface mounting, ensuring the appropriate size of the product (Mounting box to be purchased separately).
  2. Select the most suitable entry point of the mounting box (knock-out) and route the cables through. If a metal box is used, a cable grommet should be fitted to the entry point.
  3. Cables should be prepared so a sufficient conductor length reaches the terminals. Strip the ends of the individual conductors leaving an adequate length bare to enter terminals.

3. Connection (See diagram)

  1. Line up the new accessory to the mounting box and take note of where each terminal is located.
  2. Connect each wire to the matching terminal. An earth connection should always be made between the mounting box earth terminal and the accessory earth terminal, where fitted. All bare earth wires must be sheathed with green/yellow sleeving. When connecting the new accessory ensure that only the bare end of the wire enters the terminal and no bare wires are visible.
  3. Tighten terminal screws securely. (Do not over-tighten)

4. Complete Installation & Test

  1. Carefully position the accessory into the mounting box, ensuring that no wires are trapped between the plate and the wall and secure with screws (do not over-tighten) then insert screw covers (optional).
  2. Once the installation has been completed correctly, replace the fuse/ reset MCB (trip), switch the power back on at the consumer unit and test.

Cooker Control Unit

BG ELECTRICAL NPR70W Nexus Metal Switched Socket Cooker Unit -
fig

BG ELECTRICAL NPR70W Nexus Metal Switched Socket Cooker Unit -
fig2BG ELECTRICAL NPR70W Nexus
Metal Switched Socket Cooker Unit - fig3

Additional Advice for Decorative Products

The fixing method varies depending on which product range is supplied. Always ensure the wall surface is reasonably flat and smooth, with no bumps or projections. Metal front plates WITH screw fixing holes, fix the unit to the back box using two fixing screws supplied. All Decorative products MUST have an earth connection between the front plate and back box. Front plates WITHOUT screw fixing holes. These products comprise the main unit with an integral gasket and front plate as a separate items. Fix unit to the back box using two fixing screws supplied. Clip the front plate onto the main assembly, ensuring the screwdriver notch is located bottom right-hand corner. To remove the plate, place medium size flat-bladed screwdriver in the notch and lever off against the gasket.

Technical

Voltage : 220-240V ac Frequency : 50/60Hz
Rating : 45A
Live & Neutral Terminal capacity : 4 x 4mm2 3 x 6.0mm2 1 x 16mm2
Earth Terminal capacity : 3 x 4mm2 2 x 6.0mm2 1 x16mm2
Min box depth (profiled plates) : 47mm Min box depth (flat plates) : 47mm
ASTA Approved
The ASIA quality mark is evidence that the product has been independently tested to comply with the relevant clauses of the applicable standards.

Batch Code explanation

yyWxx Manufacturing date code, year of manufacture (yy) and week of manufacture (Wxx)

Care

To maintain the high-quality appearance of decorative finish switches and sockets, BG Electrical recommends the use of a soft cloth periodically to clean the front face. When installing a decorative product please ensure that the wall is decorated, finished and free of moisture prior to installation BG Electrical recommends avoiding using, but not restricted to, these substances from becoming in contact with the decorative metal front plates when cleaning or decorating:

  • Adhesive tape, including low tack masking tape
  • Solvents
  • White spirit
  • Multi-surface cleaners
  • Industrial multipurpose cleaning wipes
  • Wet wipes

Using items like those listed above may cause a degrading effect to the front- plates lacquer/plated finish, although the function will remain unaffected.

Address/Helpline

Luceco PLC
Stafford Park 1
Telford TF3 3BD
ENGLAND
(EU) Luceco SE
C/ Bobinadora 1-5
08302 Matara
SPAIN
If you have further technical assistance you can get in touch with our
Technical Helpline on:
+44 (0)3300 249 279
technicaL.support@bgelectricaL.co.uk

Environmental Protection

This symbol is known as the “Crossed-out Wheelie Bin Symbol”. When this symbol is marked on a product or battery, it means that it should not be disposed of with your general household waste. Some chemicals contained within electrical/ electronic products or batteries can be harmful to health and the environment. Only dispose of electrical/electronic/ battery items in separate collection schemes, which cater for the recovery and recycling of materials contained within. Your co-operation is vital to ensure the success of these schemes and for the protection of the environment.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

BG Electrical User Manuals

Related Manuals