BG ELECTRICAL CFE5W-01 Fortress Circuit Protection Metal Enclosure BG Catalogue Instruction Manual

October 30, 2023
BG Electrical

BG ELECTRICAL CFE5W-01 Fortress Circuit Protection Metal Enclosure BG

Catalogue

BG-ELECTRICAL-CFE5W-01-Fortress-Circuit-Protection-Metal-Enclosure-BG-
Catalogue-product

Product Information

The Fortress Circuit Protection Metal Enclosure, Part NO.: CFENIL/C, is designed to provide a safe and secure enclosure unitfor electrical components. The product is compliant with BS EN  62208, BS EN 61439-3, BS 7671 and Part P document standards. The enclosure is supplied with a busbar and neutral cable and is suitable for fitting different devices to DIN rail. The product must be installed by a competent person in accordance with the current IET Wiring Regulations (BS 7671) and BuildingRegulations.

Product Usage Instructions

  1. Disconnect the electrical supply before installation.
  2. Remove the front cover by opening the visor and undoing the retaining screws.
  3. Provide cable access via either 20mm or 32mm knockouts on the top and bottom faces, 32mm knockouts on the side faces or a large knockout in the base. Ensure IP rating is maintained e.g, use of glands.
  4. Secure the enclosure to the wall using one keyhole slot to hang it in position, ensure it is fitted level, and use other fixing holes to firmly secure it.
  5. Fit different devices to DIN rail if required, ensure cables are connected to the devices and the neutral and earth terminal bars. Ensure all connections are secure and terminal screws fullytightened. Recommended max torque for  terminal screws, MCBs and RCBOs is 2Nm, Switch is 3.5Nm, RCD is 2.5Nm.
  6. Test in accordance with the current IET wiring regulations.
  7. Add cover mounted blanks supplied if required.
  8. Refit cover and secure using screws.
  9. Apply RCD test label and circuit identification labels to the front cover above devices.

Product Guarantee

The product guarantee is valid if the following conditions are met:

  1. The product must be returned to BG Electrical.
  2. The products have only been operated under normal operating conditions and have only been subject to normal use.
  3. No work (other than normal and proper maintenance) has been carried out to the products without BG Electrical’s prior written consent.
  4. The products have been assembled, or incorporated into other goods, by a qualified and recognised electrician and only in accordance with any instructions issued by BG Electrical.
  5. The defect has not arisen from an item manufactured or supplied by a person other than BG Electrical.

Environmental Protection

Please dispose of this product responsibly and in accordance with local regulations.

Torque Settings

PZNo.| Consumer Unit Terminals| Earth and Neutral Terminal Bars| Isolation Switch Disconnector| Circuit Protection MCB| RCBO| RCD| SPD
---|---|---|---|---|---|---|---
M5| 6.5 mm| 2 mm| 1.3 mm| 9 Nm| 3.5 Nm| 2.3 Nm| 9 Nm
M6| –| –| –| –| –| 2.5 Nm| –
M7| –| –| 9.5 Nm| –| –| –| –

Note: Please refer to the torque settings table for the recommended maximum torque for each component.

Customer Support

If you require further technical assistance, please contact our Technical Helpline on: +44 (0)3300 249 279 or email us at technical.support@bgelectrical.co.uk.

Metal Enclosure
This provides a guide to the assembly and installation of the BG Electrical enclosure unit. This product must be installed by a competent person in accordance with the current IET Wiring Regulations (BS 7671) and Building Regulations.
Ensure ALL screws are fully tightened before use. (Please refer to torque settings table) Please ensure electrical supply is disconnected before installation.

Instructions

  1. Remove front cover by opening the visor, and undo retaining screws. Note – screws are captive and will not fall out.
  2. Provide cable access via either 20mm or 32mm knockouts on the top and bottom faces, 32mm knockouts on the side faces or a large knockout in the base. Only remove the minimum number required. Ensure IP rating is maintained e.g, use of glands.
  3. Secure to wall. Use one key hole slot to hang in position, ensure fitted level, use other fixing holes to firmly secure.
  4. Fit different devices to DIN rail if required, ensure cables are connected to the devices and the neutral and earth terminal bars. Note: Busbar and neutral cable are supplied with this enclosure.
  5. Ensure all connections are secure and terminal screws fully tightened. Recommended max torque for terminal screws, MCBs and RCBOs is 2Nm, Switch is 3.5Nm, RCD is 2.5Nm. (Please refer to torque settings table)
  6. Test in accordance with the current IET wiring regulations.
  7. Add cover mounted blanks supplied if required.
  8. Refit cover, and secure using screws.
  9. Apply RCD test label and circuit identification labels to front cover above devices.

General

  • Tools – Screwdriver PZ 2 or Flat screwdriver, knife and pliers.
  • Cleaning – use a soft damp cloth with luke warm water (only clean outside of unit).
  • Standards – All consumer units have been designed to comply with the requirements of
    BS EN 62208, BS EN 61439-3, BS 7671 and Part P document.

Guarantee

BG Electrical products are guaranteed against faulty materials and workmanship for a period of 10 years from date of delivery: products will be repaired or (at BG Electrical’s discretion) replacements will be supplied or (at BG Electrical’s discretion) a credit note will be issued. This guarantee is subject to BG Electrical’s conditions of sale and in particular to the following conditions being met:

  1. Notification of any defect is given to BG Electrical as soon as reasonably practicable after becoming apparent, and the products then returned to BG Electrical.
  2. The products have only been operated under normal operating conditions and have only been subject to normal use.
  3. No work (other than normal and proper maintenance) has been carried out to the products without BG Electrical’s prior written consent.
  4. The products have been assembled, or incorporated into other goods, by a qualified and recognised electrician and only in accordance with any instructions issued by BG Electrical.
  5. The defect has not arisen from an item manufactured or supplied by a person other than BG Electrical. This guarantee does not affect any consumer statutory rights.
    All components used in a BG Electrical enclosure, must be supplied by BG Electrical. The use of any other components will negate compliance to BS EN 61439 and the BG Electrical Guarantee. Failure to fit the enclosure in accordance with these instructions will invalidate the guarantee.

Batch Code Explanation
yWxx: Manufacturing date code; year of manufacturing (yyl and week of manufacturing (Wxx)

Address/Helpline

Luceco PLC
Stafford Park 1
Telford TF3 3BD
ENGLAND

(EU) Luceco SE
C/ Bobinadora 1-5
08302 Mataró
SPAIN

If you have further technical assistance you can get in touch with ourTechnical Helpline on: +44 (0)3300 249 279
technical.support@bgelectrical.co.uk

Environmental Protection

This symbol is known as the “Crossed-out Wheelie Bin Symbol”. When this symbol is marked on a product or battery. It means that it should not be disposed of with your general household waste. Some chemicals contained within electrical/electronic products or batteries can be harmful to health and the environment. Only dispose of electrical/electronic/ battery items in separate collection schemes, which cater for the recovery and recycling of materials contained within. Your co-operation is vital to ensure the success of these schemes and for the protection of the environment.

Torque Settings|

|

| Cable >1.5mm² Tightening torque (Nm)| Cable ≤1.5mm² Tightening torque (Nm)| Cable stripping (mm)
---|---|---|---|---|---
Consumer Unit Terminals
Earth and Neutral Terminal Bars| M5| 6.5| 2| 1.3| 11
Isolation
Switch Disconnector| M7| 9| 3.5| 2.3| 14
Circuit Protection
MCB| M5| 9| 2| 1.3| 12

RCBO

|

M5

|

9

| 2Nm L / in – 1.2Nm L / N out|

1.3

|

12

RCD| M6| 9.5| 2.5| 1.3| 14

SPD

|

M5

|

9

| 2Nm PE

1.2Nm L / N

|

1.3

|

12

Interface Characteristics

Interface Characteristics

Rated & Operational voltage (Un / Ue)| 230V A.C 50Hz
Rated & Insulation voltage (Ui)| 500V A.C 50Hz
Rated impulse withstand voltage (Uimp)| 4kV
Rated current of the Assembly (InA)

Note: dependant upon rating of main incoming device

|

40A, 63A, 80A, 100A

Rated current of an outgoing circuit (Inc)| MCB 6A-50A (marked rating of current on device) RCBO 6A-40A (marked rating of current on device)
Rated current of outgoing unit (Inc)| RCD 40A 63A 80A 100A (marked rated current on device)
Rated conditional short-circuit current of the assembly (Icc)| ICC=16KA
Protection against electric shock| Consumer unit shall be installed in an electrical system conforming to the current edition of IEC 60364 / BS7671
Rated diversity factor (RDF) / Values of assumed loading| Note: RDF only applies to continuously and simultaneously loading circuits. In principle this means adjacent circuit breakers having a load ‘on’ time exceeding 30 minutes or where a load

not exceeding 30 minutes has an ‘off’ timeless than the ‘on’ time will need to have the rating diversity factor applied as indicated Table and ratings based on a continuous rating of 90A

Rated Frequency (fn)| 50Hz
Pollution degree| 2
Types of earthing system for which the assembly is designed| Indoor use only Stationary Assembly
Degree of protection| IP2XC/IP65

Intended for use in domestic (residential) or similar premises

Electromagnetic compatibility (EMC) classification| A
External design| Wall-mounted, surface type, enclosed assembly
Mechanical impact protection| IK05
The type of construction| Fixed parts
Type A DBO| Distribution board for use by ordinary persons

Read User Manual Online (PDF format)