stelpro DBI SERIES ALUMINUM DRAFT BARRIER User Guide
- June 5, 2024
- StelPro
Table of Contents
USER’S GUIDE
DBI SERIES
ALUMINUM DRAFT BARRIER
REPLACEMENT COMPONENTS LIST INCLUDE
This unit complies with the CSA and UL standard
IMPORTANT INSTRUCTIONS
Before installing and operating this product, the user and/or installer must
read, understand and follow these instructions and keep them handy for future
reference. If these instructions are not followed, the warranty will be
considered null and void and the manufacturer deems no further responsibility
for this product.
This product must be installed by a qualified person and connected by a
certified electrician , according to the electrical and building codes
effective in your region.
The following instructions must be adhered to in order to avoid personal
injuries or property damages, serious injuries, and potentially fatal electric
shocks.
Protect the heating unit with the appropriate circuit breaker or fuse, in
accordance with the nameplate.
Make sure the line voltage (volt) is consistent with that indicated on the
unit’s nameplate.
This unit must be grounded.
Switch off the power at the circuit breaker/fuse before installing, repairing,
and cleaning the unit.
Make sure the unit is appropriate for the intended use (if needed, refer to
the product catalog or a representative).
RECOMMENDED HEATING CAPACITY: 1.25 W/cubic foot (0.03 m³).
It corresponds to 10 W/square foot (0.09 m²) based on a standard ceiling
height of 8 feet (2.44 m). The recommended capacity is usually sufficient for
normal heating needs. Please note that the insulation quality of walls and
windows are some of the factors that influence heat losses, which modify the
required capacity to heat a room. If needed, refer to a specialist who will be
able to calculate these heat losses and optimize the required capacity or
consult the “Online heating calculation” section of the Stelpro Design Web
site (residential buildings). To heat a large room and increase your comfort,
it is recommended to install several units instead of one. For example, 2 X
1000 W rather than 1 X 2000 W.
Do not install the unit where objects or pieces of furniture could be heat
damaged. If the unit’s capacity is insufficient for the size of the room, it
will be in operation continuously and may become defective earlier and turn
yellow. Respect distances and positions indicated in the installation
section.
If the installer or user modifies the unit, they will be held responsible for
any damage resulting from this modification, and the CSA certification could
be void. This unit must not come into contact with a water source and must be
protected from splashes (e.g. a wet mop). Do not use it if any part has been
immersed. Moreover, do not turn it on or off when standing in water or if your
hands are wet.
When cutting or drilling into a wall, do not damage electrical wiring and
other hidden utilities.
Do not install this product on walls made of synthetic material such as, but
not limited to, carpet and wallpaper. When starting up the unit for the first
time or after a long period, it is normal that it produces some temporary
odors and whitish smoke. Because this unit is hot when in use, it may pose
risks even in normal operation.
Therefore, be careful and responsible when using it. To avoid burns, do not
let bare skin touch hot surfaces. Let the unit cool down for a few minutes
before handling (it will stay warm for some time after shut-down). If
provided, use handles when moving this heater.
Leave a 2-inch (5 cm) clearance space between unit and floor (when
installed with the DBIBT accessory only). Leave at least 3 inches (7.5 cm)
between the front of the unit and objects that have a ground clearance of at
least 1 inch (2.5 cm) such as, but not limited to, beds, tables, armchairs,
curtains, etc. If these objects are located directly on the floor, leave at
least 6 inches (15 cm) between them and the front of the unit. Leave at least
6 inches (15 cm) of space between the top of the unit and objects such as, but
not limited to furniture, pillows, curtains, blankets, towels, laundry
baskets, clothing, papers, etc. Furthermore, certain materials are more
sensitive to heat than others, you must assure that these materials are
located in proper proximity where they can handle the heat released.
Do not install it on a wall behind a door.
Never block air vents. This obstruction could lead to overheating, which could
result in a fire. Do not use it on soft surfaces, like a bed, where openings
may become blocked. Do not insert or allow foreign objects to enter any air
vent as this may cause electric shocks, a fire, or damage to the unit. This
unit has hot and arcing or sparking parts inside. It is not designed to be
used or stored in wet areas or areas containing flammable liquids, combustible
materials, or corrosive, abrasive, chemical, explosive and flammable
substances such as, but not limited to, gasoline, paint, chlorine, sawdust,
and cleaning products.
Some areas are dustier than others. Thus, it is the user’s responsibility to
evaluate if the unit must be cleaned based on the amount of dirt accumulated
on and inside air vents. Accumulated dirt can lead to a component malfunction
or give a yellowish color to the unit. Failure to install and maintain the
unit in accordance with these instructions poses a fire hazard.
Thermal protection activation indicates that the unit has been subjected to
abnormal operating conditions. If the thermal protection remains activated or
activates and deactivates repeatedly, it is recommended that a qualified
electrician or a certified repair center examine the unit in order to make
sure it is not damaged. (Refer to the LIMITED WARRANTY) If the unit is damaged
or defective, cut off the power supply at the circuit breaker and call a
certified repair center. (Refer to the LIMITED WARRANTY)
SAVE THESE INSTRUCTIONS
NOTE: When a part of the product specification must be changed to improve operability or other functions, priority is given to the product specification itself. In such instances, the instruction manual may not entirely match all the functions of the actual product. Therefore, the actual product and packaging, as well as the name and illustration may differ from the manual.
SPECIFICATIONS
250 W density per linear foot| 200 W density per linear foot| 150
W density per linear foot| voltage| length| weight
---|---|---|---|---|---
CODE| WATTS| CODE| WATTS| CODE| WATTS|
VOLTS| MM| IN.| KG| LB
DBI6051| 500| DBI6041| 400| DBI6031| 300 W| 120| 600| 23
5/8| 3.1| 6.7
DBI9071| 750| DBI9061| 600| DBI9041| 450 W| 120| 900| 35
7/16| 4.6| 10.1
DBI12101| 1000| DBI12081| 800| DBI12061| 600 W| 120| 1200|
47 1/4| 6.8| 13.4
DBI15121| 1250| DBI15101| 1000| DBI15071| 750 W| 120| 1500|
59 1/16| 7.6| 16.8
DBI18151| 1500| DBI18121| 1200| DBI18091| 900 W| 120| 1800|
70 7/8| 9.1| 20.1
DBI21178| 1750| DBI21148| 1400| DBI21108| 1050 W| 208| 2100|
82 11/16| 10.6| 23.4
DBI24208| 2000| DBI24168| 1600| DBI24128| 1200 W| 208| 2400|
94 1/2| 12.2| 26.8
DBI27228| 2250| DBI27188| 1800| DBI27138| 1350 W| 208| 2700|
106 5/16| 13.6| 30.1
DBI27258| 2500| DBI27208| 2000| DBI27158| 1500 W| 208| 2700|
106 5/16| 13.6| 30.1
Add W for white, SW for silica white or CA for clear anodize
TECHNICAL DRAWINGS & INSTALLATION
TECHNICAL DRAWING
INSTALLATION
CAUTION – HIGH TEMPERATURE, KEEP ELECTRICAL CORDS, DRAPES, AND OTHER
FURNISHINGS AWAY FROM UNIT.
Keep drapes at a distance of at least 6 inches (15 cm) from the unit.
Do not install the unit against combustible low-density cellulose fiberboard
surfaces or below an electrical convenience receptacle.
To reduce the risk of fire, do not store or use gasoline or other flammable
vapors and liquids in the vicinity of the unit. Do not install the unit in
contact with combustible materials.![stelpro DBI SERIES ALUMINUM DRAFT BARRIER
- CLEARANCE REQUIRED](https://manuals.plus/wp-content/uploads/2022/07/stelpro- DBI-SERIES-ALUMINUM-DRAFT-BARRIER-CLEARANCE-REQUIRED.png)
N.B. The illustration indicates the airflow generated by the baseboard
heater.
This air corridor must remain clear in order to allow the unit to operate
efficiently; ensure good air circulation and avoid a fire hazard.
Leave at least 3 inches (7.5 cm) between the front of the unit and objects
that have a ground clearance of at least 1 inch (2.5 cm) such as, but not
limited to, beds, tables, armchairs, curtains, etc. If these objects are
located directly on the floor, leave at least 6 inches (15 cm) between them
and the front of the unit. Leave at least 6 inches (15 cm) of space between
the top of the unit and objects such as, but not limited to furniture,
pillows, curtains, blankets, towels, laundry baskets, clothing, papers, etc.
Furthermore, certain materials are more sensitive to heat than others, you
must assure that these materials are located in proper proximity where they
can handle the heat released.
Cut off power supply at circuit breaker/fuse before proceeding with the
installation.
This product is for surface mounting only. When installed with the DBIBT
accessory, this product must have a 2-inch clearance space between the unit
and the floor. Optional blank sections and fillers are available for a
continuous effect. To install accessories (built-in thermostat or relay),
refer to the appropriate installation guide.
- Remove cover.
- Secure the unit on the wall using screws.
- Put back cover.
When cutting or drilling into a wall, be careful not to damage electrical wiring and other hidden utilities.
INSTALLATION & OPERATION
BUILT-IN THERMOSTAT
- Install the mounting screws in the appropriate holes.
- Install the thermostat bulb at the bottom of the unit.
ELECTRICAL CONNECTION
Cut off power supply at circuit breaker/fuse before proceeding with the
installation.
Secure the bare wire (ground) from the electrical box to the green screw of
the unit. Connect wires from the electrical box to the unit’s supply leads
using connectors (marettes). N.B. This unit must be connected by a qualified
electrician, according to the electrical and building codes effective in your
region.
ELECTRICAL DIAGRAM
OPERATION
WARNING : The unit must be properly installed before being used.
TROUBLESHOOTING & REPLACEMENT COMPONENT LIST
TROUBLESHOOTING
PROBLEM | DEFECTIVE PART OR PART TO CHECK |
---|---|
The unit does not work | • Defective thermostat or wrong thermostat setting |
• Open circuit breaker or fuse
• Activated thermal protection
• Faulty connections
• Damaged or defective plug or outlet
The unit runs continuously| • Defective thermostat or wrong thermostat
setting
• Heat losses greater than the unit’s capacity
The enclosure is extremely hot| • Defective thermal protection
• Blocked air vents
• Defective motor
The unit cycles under the control of the thermal protection (overheat
indicator)| • Blocked air vents
Overheating| • Defective thermostat or wrong thermostat setting
The breaker trips when the heater is turned on| • Faulty connections
• Voltage higher than indicated on the nameplate
The desired room temperature cannot be reached| • One or more defective
elements
• Defective thermostat or wrong thermostat setting
• Voltage lower than indicated on the nameplate
• Heat losses greater than the unit’s capacity
N.B. If you do not solve the problem after checking these points, cut off the power supply at the main electrical panel and contact our customer service (see the “LIMITED WARRANTY” section to obtain the phone numbers).
REPLACEMENT COMPONENT LIST
REF. # | PART # | DESCRIPTION |
---|---|---|
1 | EA0300-06-*** | ELEMENT 300 W (600 MM) |
1 | EA0400-06-*** | ELEMENT 400 W (600 MM) |
1 | EA0450-09-*** | ELEMENT 450 W (900 MM) |
1 | EA0600-09-*** | ELEMENT 600 W (900 MM) |
1 | EA0600-12-*** | ELEMENT 600 W (1200 MM) |
1 | EA0750-09-*** | ELEMENT 750 W (900MM) |
1 | EA0750-15-*** | ELEMENT 750 W (1500 MM) |
1 | EA0800-12-*** | ELEMENT 800 W (1200 MM) |
1 | EA0900-18-*** | ELEMENT 900 W (1800 MM) |
1 | EA1000-12-*** | ELEMENT 1000 W (1200 MM) |
1 | EA1000-15-*** | ELEMENT 1000 W (1500 MM) |
1 | EA1050-21-*** | ELEMENT 1050 W (2100 MM) |
1 | EA1200-18-*** | ELEMENT 1200 W (1800 MM) |
1 | EA1200-24-*** | ELEMENT 1200 W (2400 MM) |
1 | EA1250-15-*** | ELEMENT 1250 W (1500 MM) |
1 | EA1350-27-*** | ELEMENT 1350 W (2700 MM) |
1 | EA1400-21-*** | ELEMENT 1400 W (2100 MM) |
1 | EA1500-18-*** | ELEMENT 1500 W (1800 MM) |
1 | EA1500-27-*** | ELEMENT 1500 W (2700 MM) |
1 | EA1600-24-*** | ELEMENT 1600 W (2400 MM) |
1 | EA1750-21-*** | ELEMENT 1750 W (2100 MM) |
1 | EA1800-27-*** | ELEMENT 1800 W (2700 MM) |
1 | EA2000-24-*** | ELEMENT 2000 W (2400 MM) |
1 | EA2000-27-*** | ELEMENT 2000 W (2700 MM) |
1 | EA2250-27-*** | ELEMENT 2250 W (2700 MM) |
1 | EA2500-27-*** | ELEMENT 2500 W (2700 MM) |
2 | PROT-120 | LINEAR THERMAL PROTECTION (AUTO.) (L200) 600MM |
2 | PROT-121 | LINEAR THERMAL PROTECTION (AUTO.) (L200) 900MM |
2 | PROT-122 | LINEAR THERMAL PROTECTION (AUTO.) (L200) 1200MM |
2 | PROT-123 | LINEAR THERMAL PROTECTION (AUTO.) (L200) 1500MM |
2 | PROT-105 | LINEAR THERMAL PROTECTION (AUTO.) (L200) 1800MM |
2 | PROT-106 | LINEAR THERMAL PROTECTION (AUTO.) (L200) 2100MM |
2 | PROT-108 | LINEAR THERMAL PROTECTION (AUTO.) (L200) 2400MM |
2 | PROT-109 | LINEAR THERMAL PROTECTION (AUTO.) (L200) 2700-3000MM |
MAINTENANCE
N.B. The unit should be cleaned at least once a year. All other servicing is to be done by qualified service personnel. This unit must be cleaned regularly In order for the warranty to be valid. Make sure the power has been turned off at the circuit breaker panel an
d that the heating element has cooled before cleaning the unit or before
removing the grill for cleaning and lubrication. WARNING: if the unit is
equipped with a circuit breaker, the power supply at the main breaker must be
turned off before removing the cover of the junction box or opening or closing
the unit’s circuit breaker.
Use a soft rag for dusting. When cleaning, use only a damp rag and non-
abrasive dish soap. If you use a cleaning product, always wipe the product off
properly to avoid the discoloration of the unit. Do not use abrasive or
chemical cleaners because they can damage the finishing. If the unit is used
in a very dusty location, use a vacuum brush to remove dust and other foreign
objects from the grilles. Note that cigarette smoke could yellow the discharge
grille and that the best way to prevent this problem is to clean the unit
regularly.
Don’t forget to replace the front grille (with the screws that were removed)
if it was removed for cleaning.
Restore the power when cleaning or lubrication work is complete.
Do not use cleaning products identified with these symbols:
N.B. Note that there is an electrical current to the unit even if the thermostat is off. Meaning that there is a risk of electric shock as long as the unit is energized.
LIMITED WARRANTY
This limited warranty is offered by Stelpro Design Inc. (“Stelpro”) and
applies to the following product made by Stelpro: model DBI. Please read
this limited warranty carefully. Subject to the terms of this warranty,
Stelpro warrants its products and their components against defects in
workmanship and/or materials for the following periods from the date of
purchase: 3 years. This warranty applies only to the original purchaser;
it is non-transferable and cannot be extended.
Claim procedure
If at any time during the warranty period the unit becomes defective, you must
cut off the power supply at the main electrical panel and contact 1) your
installer or distributor, 2) your service center or 3) Stelpro’s customer
service department. In all cases, you must have a copy of the invoice and
provide the information written on the product nameplate. Stelpro reserves the
right to examine or to ask one of its representatives to examine the product
itself or any part of it before honoring the warranty. Stelpro reserves the
right to replace the entire unit, refund its purchase price, or repair a
defective part. Please note that repairs made within the warranty period must
be authorized in advance in writing by Stelpro and carried out by persons
authorized by Stelpro.
Before returning a product to Stelpro, you must have a Stelpro authorization
number (RMA). To obtain it, call the customer service department at:
1-800-363-3414 (electricians and
distributors – French), 1
-800-343-1022 (electricians and
distributors – English), or
1-866-766-6020 (consumers). The
authorization number must be clearly written on the parcel or it will be
refused.
Conditions, exclusions, and disclaimer of liability
This warranty is exclusive and in lieu of all other representations and
warranties (except title), expressed or implied, and Stelpro expressly
disclaims and excludes any implied warranty of merchantability or implied
warranty of fitness for a particular purpose.
Stelpro’s liability with respect to products is limited as provided above.
Stelpro shall not be subject to any other obligations or liabilities
whatsoever, whether based on contract, tort, or other theories of law, with
respect to goods or services furnished by it, or any undertakings, acts, or
omissions relating thereto. Without limiting the generality of the foregoing,
Stelpro expressly disclaims any liability for property or personal injury
damages, penalties, special or punitive damages, damages for lost profits,
loss of use of equipment, cost of capital, cost of substitute products,
facilities, or services, shutdowns, slowdowns, or for other types of economic
loss or for claims of a dealer’s customers or any third party for such
damages. Stelpro specifically disclaims all consequential, incidental, and
contingent damages whatsoever.
This warranty does not cover any damages or failures resulting from 1) a
faulty installation or improper storage; 2) an abusive or abnormal use, lack
of maintenance, improper maintenance (other than that prescribed by Stelpro),
or use other than that for which the unit was designed; 3) a natural disaster
or an event out of Stelpro’s control, including, but not limited to,
hurricanes, tornadoes, earthquakes, terrorist attacks, wars, overvoltage,
flooding, water damages, etc. This warranty does not cover any accidental or
intentional losses or damages, nor does it cover damages caused by the
negligence of the user or owner of the product. Moreover, it does not cover
the cost of disconnection, transport, and installation.
The warranty is limited to the repair or the replacement of the unit or the
refund of its purchase price, at the discretion of Stelpro. Any parts
replaced or repaired within the warranty period with the written authorization
of Stelpro will be warranted for the remainder of the original warranty
period. This warranty will be considered null and void and Stelpro will have
the right to refuse any claims if products have been altered without the
written authorization of Stelpro and if the nameplate numbers have been
removed or modified. This warranty does not cover scratches, dents, corrosion,
or discoloration caused by excessive heat, chemical cleaning products, and
abrasive agents. It does not cover any damage that occurred during the
shipping.
Some states and provinces do not allow the exclusion or limitation of
incidental or consequential damages and some of them do not allow limitations
on how long an implied warranty lasts, so these exclusions or limitations may
not apply to you. This warranty gives you specific legal rights and you may
have other rights which vary from state to state or from province to province.
STELPRO DESIGN INC. | Saint-Bruno-de-Montarville | Quebec | J3V 6L
Documents / Resources
|
stelpro DBI SERIES ALUMINUM DRAFT
BARRIER
[pdf] User Guide
ALUMINUM DRAFT BARRIER, DRAFT BARRIER, ALUMINUM, DBI SERIES
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>