dresden elektronik TX Measurement DEKO Light Conbee Instructions
- June 3, 2024
- dresden elektronik
Table of Contents
- dresden elektronik TX Measurement DEKO Light Conbee
- Device list
- Charging the devices
- Antenna Gain measurement
- Test Setup radiated (TX)
- FCC Band edge
- Blocking
- Full functional devices DUT 1 and 2
- ESD and Immunity tests EN301 489-1/-17
- Emissions CE/FCC Part 15b
- Ecodesign/Photobiosafety/CEC&DOE
- Contacts
- FCC warnings
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
dresden elektronik TX Measurement DEKO Light Conbee
Device list
Following DUTs are provided and labeled with their name on the bottom:
Quantity | Name | Description |
---|---|---|
1 | DUT 1 | Device under test (full functional device) |
1 | DUT 2 | Device under test (full functional device) |
1 | DUT 3 RAIL | Railtest fixed frequency device (for radiated measurements) |
1 | DUT 4 RAIL | Railtest fixed frequency device (for radiated measurements) |
1 | DUT 5 ANT | Antenna with u.FL to SMA connector 0.5dB attenuation (for |
measuring antenna gain)
1| DUT 6 COND| Device with conducted RF output with u.FL to SMA connect- or
0.5dB attenuation (for conducted measurements)
Additional equipment:
1| EUT 1| USB dongle Zigbee hub
1| EUT 2| USB charger 3 way IKEA
1| EUT 3| Qi-Pad wireless charger Samsung EP-P1100
3| charging cable| USB-A to microUSB charging cable 200mm
2| data cable| USB-A to microUSB data cable 1000mm
1| Power cable Qi| USB-A to USB-C power cable 1000mm for Qi-Pad
Charging the devices
DUT 1, 2, 3, 4 and 6 have a battery which needs to be recharged from time to
time.
To recharge use the EUT 2 Charger and the charging cables provided or any 5V
USB power adapter. Charging time is approx. 3-4 hours from empty to full. The
status LED next to USB connector indicates charging by blinking blue and
charge finished by continuous blue light.
In use, when status LED is red then battery is almost empty (<10% SOC).
Orange indicates normal operation
Green when full
LED Turns off after ~20seconds, to turn on again press the button or turn the
upper part.
Antenna Gain measurement
At first, the gain of the pcb antenna needs to be measured with DUT 5. It
includes the u.FL to SMA connector with 0.5dB attenuation.
Please provide peak gain and radiation patterns. We can then define the max.
output power for the following measurements.
Test Setup radiated (TX)
DUT: DUT 3/4
Supply: Battery
Charging: USB
RF: Onboard PCB antenna
Devices need charging before use. After fully charged DUT 3/4 can last for 2-6 days depending on usage.
Preparation for Test
DEKO (DUT 3/4 railtest FW)
Install the driver from zip file or web (http://www.wch.cn/downloads/CH341SER_ZIP.html)
Open a terminal tool like Putty or hTerm (installer provided with zip file) with COM Port, 115200 Baud 8N1.
To configure for Zigbee execute the following commands, each command needs to be terminated by CR (enter):
To configure for Bluetooth execute the following commands, each command needs to be terminated by CR:
or
This table shows the conducted nominal measured output power versus the power setting.
TX Out con- ducted measurement [dBm]| TX Out radiated [dBm]
(calculated)| TX Power [dec dBm]
---|---|---
To enter when changing power
10.7| Gain required (see 3. Antenna Gain measurement)| 100
9.9| | 90
8.8| | 80
8.3| | 70
7.7| | 61
7.0| | 51
5.9| | 41
5.3| | 29
4.4| | 17
4.0| | 11
2.8| | 1
2.1| | -9
1.3| | -19
-0.5| | -29
-1.8| | -40
-3.2| | -57
-5.0| | -74
-7.4| | -96
-10.7| | -144
-16.2| | -260
All other options shall not be modified. The procedure is the same for all DUTs.
Transmit Mode
To start continuous transmission: setTxStream 1 0 0 carrier (tone) or setTxStream 1 1 0 modulated signal (PN9)
Remove USB cable for measurements after start the transmission!
To stop transmission: setTxStream 0
Receive Mode
In receive mode the DUT will listen to packets on the specified channel and
print the received packet to the console.
Start receive mode: rx 1
Stop receive mode: rx 0
Communication partner for EMC Test (DUT3/4)
- Plug the second DUT3/4 into USB
- Open a terminal tool like Putty or hTerm with COM Port, 115200 Baud 8N1.
- Send following commands:
setchannel
Start receive mode: rx 1
SAR
Please conduct the SAR measurement at the body worn distance.
FCC Band edge
For Zigbee Channel 26 and maybe Bluetooth Channel 39 it might be necessary to reduce output power to pass the band edge test. Reduce transmit power step by step until it passes the test. Inform us about used power setting or in case of any problems.
Blocking
DUT 3 or 4 as transmitter, enable CSMA for Zigbee as follows:
for Bluetooth use:
Full functional devices DUT 1 and 2
Manual control
DUT 1 and 2 are delivered in power off state. To turn them on press the upper shell down once and turn first left, then right at least one fourth turn each. When turned on, the DUT will light up with low brightness. Turn right to increase the brightness and left reduces brightness. In this state it can be controlled by PC tool deCONZ via Zigbee.
The device has following manual control modes:
- Press once will enter brightness control
- Press twice will enter the colour temperature mode
- Press three times will enter colour control mode
- Press 10 seconds to enter power off mode
Setup PC Tool for DUT1/2 control
Setup steps:
- Install deCONZ from web https://deconz.dresden-elektronik.de/win/ newest Version as of writing: 2.16.01
- Plug EUT 1 into USB port
- Install USB driver (automatically by windows)
- Run deCONZ
- Turn on DUT (see section 7.1)
- Activate Control panel Panels > Control
- Open Network by Enable Permit join in Control Panel > Pairing
- Wait until DUT shows up in main view on the right
Control DUT 1 and 2 remotely by pc Software deCONZ
To set the brightness for the DUT (screenshots below):
-
Run deCONZ
-
Select cluster info
-
Click the right dot at the DUT in main view to open the cluster list
-
Click Level Control
-
Move to Level 255 > Exec (full brightness), 0 (minimum brightness)
To set the color of the light to a specific value, use 1.-3. And the following steps: -
Click Color Control
-
Move to Hue: 0 for red, 85 green, 170 blue > Exec
To set the color temperature of the light to a specific value, use 1.-3. And the following steps: -
Click Color Control
-
Move to color temperature cold white: 153 warm white: 370 > Exec
ESD and Immunity tests EN301 489-1/-17
DUT 1 and EUT 1 form a network, light is turned on. Then Test, Result=?
DUT 1 and EUT 1 form a network, light is turned off. Then Test, Result=?
After Test, send commands from deCONZ, intended changes happened?
Emissions CE/FCC Part 15b
DUT 1 and EUT 1 form a network, light is turned on 50% mixed warm/cold white
full brightness with color temperature 262 (see 7.3).
DUT 1 put on Qi Pad for Charging (EUT3 with EUT2 and USB-C cable provided)
DUT 1 charging by microUSB cable and EUT2
Ecodesign/Photobiosafety/CEC&DOE
DUT 1 or 2 can be used for these tests.
Contacts
Stephan Frach
Tel: +49 351 31850-886
stf@dresden-elektronik.de
Andreas Palm
Tel: +49 351 31850-39
apa@dresden-elektronik.de
Kevin He
Tel: +86 135 1061 8185
kevin.he@noa-labs.com
FCC warnings
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Specific Absorption Rate (SAR) information:
This Mobile Phone meets the government’s requirements for exposure to radio
waves. The guidelines are based on standards that were developed by
independent scientific organizations through periodic and thorough evaluation
of scientific studies. The standards include a substantial safety margin
designed to assure the safety of all persons regardless of age or health.
FCC RF Exposure Information and Statement The SAR limit of USA (FCC) is 1.6
W/kg averaged over one gram of tissue.
Device types: Decolight (FCC ID: XVV-HIVE) has also been tested against
this SAR limit. The highest SAR value reported under this standard during
product certification for properly worn on the body is 0.150W/kg. This device
was tested for typical bodyworn operations with the back of the handset kept
0mm from the body. To maintain compliance with FCC RF exposure requirements,
use accessories that maintain a 0mm separation distance between the user’s
body and the back of the handset. The use of belt clips, holsters and similar
accessories should not contain metallic components in its assembly. The use of
accessories that do not satisfy these requirements may not comply with FCC RF
exposure requirements, and should be avoided.
Body-worn Operation
This device was tested for typical body-worn operations. To comply with RF exposure requirements, a minimum separation distance of 0mm must be maintained between the user’s body and the handset, including the antenna. Third-party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components. Body-worn accessories that do not meet these requirements may not comply with RF exposure requirements and should be avoided. Use only the supplied or an approved antenna.
IC Caution
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) This device may not
cause interference, and (2) This device must accept any interference,
including interference that may cause undesired operation of the device.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>