WOHLER Indoor Air Quality Software User Guide

June 15, 2024
WOHLER

WOHLER Indoor Air Quality Software User Guide
WOHLER Indoor Air Quality Software

System Requirements

Description Specification
Processor Pentium 42.4 GHz and higher
RAM 512 MB or more
Others Graphic board
System requirements Windows 7,Windows 8,Windows 10.Windows 11

Application

With the Wöhler Indoor Air Quality software the data measured by the Wöhler CDL 210 or KM 410 is transmitted to the PC where it can be analyzed.

First Steps

Fig. 1: Rear side of the Wöhler CDL 210 with USB cable and power supply.
First Steps

NOTE!
For information about the installation of the USB driver, see the manual USB cable. (art. n° 22354).

  • Before you can start to transmit the data, you have to install the USB driver.
  • Connect the Wöhler CDL 210 or KM 410 to the PC via the USB cable by plugging the cable plug into the socket at the rear side of the device and inserting the USB plug into the USB port of your computer.
  • Start the Indoor Air Quality Software.
  • Install the software by clicking on the installation software.

NOTE!
If you work with Windows 10, an error message concerning your administrator rights may appear when you open the Exe-File. In this case click the right mouse button on the file icon and select “Run as administrator”.

NOTE!
If you start the program for the first time, the language will be German.

  • To change the language select „ Einstellungen>Sprache>German“

The program will automatically start again.

Fig. 2: Changing the language

Changing the language

Screen Explanation

After the program has been started, the main display will appear on screen:

Fig. 3: main display
Main Display

Number Function
1 Settings of the selected logging process
2 Records
3 Notes: Here the user can add a comment that will be saved with the readings

in the data base
4| Read out the Data stored by the CDL 210 or KM 410
5| Selection of the measurement readings
6| Menu
7| DiagramThe diagram can be scaled with the mouse wheel. Right mouse button: Menu

Selecting The Com Port

Fig. 4: Selecting the Com Port
Selecting the Com Port

  • To select the com port click Settings > COMPort in the menu bar (Fig. 2, Part 5)

NOTE!
If the selected com port is not indicated, the reason could be that the Wöhler CDL 210 or KM 410 was connected to the PC after the software had been started. In this case finish the software and start it again.

Data Transmission

Logger Values

Fig. 5: Reading the data
Reading the data

  • Click on “Read data” to start the data transmission. (Fig. 2, part 4)

The Software will start reading the information of the memory of the Wöhler CDL 210 or KM 410. A status bar in the bottom left-hand corner of the screen shows the progress of the data reading. A short peep of the meter will show that the data reading process has been finished and a graph will appear on screen.

Fig. 6: Displaying the value of a certain reading in the graph.

NOTE!
Scale the graph with the mouse wheel. Open the graph menu with a right mouse- click. Now you can copy, save or print the graph. You can also display the value corresponding to a single point of the graph. (see figure on the left).

Online-Values

Fig. 7: Online Measurement
Online Measurement

When you start the online measurement, the values measured by the Wöhler CDL 210 or KM 410 will be transmitted directly to the PC.
In the main screen, click on “Online-Values”.

  • In the field “Log rate” enter the sampling interval.
  • Start the online measurement by clicking intothe field “Online Measurement” (a tick markwill be placed).
  • Stop the online measurement by clicking once again into the field “online measurement” (the tick mark will be removed).

For the graph, see note in chapter 6.1.

Customer data

Create and manage customer data

Fig. 8: Customer data
Customer data

  • Select “Settings>Customer data”
  • Click on “New” and enter the data of your customer.
  • Click on “OK” and confirm the data.
  • In the submenu “customer data” select a customer and click on “Change” to change the data.
  • In the submenu “customer data” select a customer and click on “Delete” to delete the data.
Assigning measured values to a customer

The program will save the new reading under “0” (main screen).

  • With the right mouse key, click on the data record that you want to assign to a certain customer.

Fig. 9: Selecting the data
Selecting the data

  • A window will open. Click on the small arrow. All customers that have been created will be shown.
  • Select the customer to whom you want to assign the data record.

Fig. 10: Assigning data records to a customer

Option “File”

Item “Export > act. measurement”

The actual measurement will be exported as an csv-file and saved to the path selected by the user. The data can be analyzed in an excel file.

NOTE!
The exported csv files cannot be re imported to the PC software Wöhler CDL 210 or KM 410.

Menu item “Export > database”
With this item, all data saved by the Indoor Air Quality software will be exported to a databasefile and saved to the path selected by the user.

Item „Import“
With this item the databases exported from the Indoor Air Quality software can be re imported.

  • Select File>Import A window will open. Select the path to your database.
  • Select the databases to be imported and click on “rubbernecker”.

NOTE!
The items “Import” and “Export” permit to merge the databases from different laptops or PCs.

Item “Print”
Print a measurement report with logo, company address (if entered, Settings > Company address) measured values represented in a graph and a field for signature and stamp.

Item “Delete”
Delete the selected database.

Item “Delete all”
Delete all databases saved in the Indoor Ai8r Quality Software.

Item “Exit”
Exit the Indoor Air Quality software.

Option “Settings”

Item “Log rate (CDL 210)”

The log rate calculator helps the user to set the log rate.

  • Enter the start time and the log rate. After that the program will calculate the stop time of the data logging process.

Fig. 11: Log rate calculator
Log rate calculator

Item “Temperature”
Select Fahrenheit or degree (Celsius)

Item „Company Address“
The company address will appear on the measurement report.

Fig. 12: Enter a company address
Enter a company address

Item “Language”
Select German, English or French.

NOTE!
After changing the language, the program will start again.

Option Info

Item “Update”

If there is a new software version available, the download button will be active and the user can download the actual version.

NOTE!
The PC must be connected to the internet.

Fig. 13: Software Update
Software Update

Item “Info” Version,
system information and manufacturer’s address

Points of sale and service

Germany
Wöhler Technik GmbH
Wöhler-Platz 1
33181 Bad Wünnenberg
Tel.: +49 2953 73-100
Fax: +49 2953 73-96100
[email protected]
www.woehler.de

Wöhler West
Castroper Str. 105
44791 Bochum
Tel.: +49 234 516993-0
Fax: +49 234 516993-99
[email protected]

Wöhler Süd
Gneisenaustr.12
80992 München
Tel.: +49 89 1589223-0
Fax: +49 89 1589223-99
[email protected]

USA
Wohler USA Inc.
5 Hutchinson Drive
Danvers, MA 01923
Tel.: +1 978 750 9876
Fax.: +1 978 750 9799
www.wohlerusa.com

Italy
Wöhler Italia srl
Via Coraine 21
37010 Costermano VR
Tel. +39 045 6200080
Fax. +39 045 6201508
www.woehler.it

Austria
Wöhler GmbH
Heinrich-Schneidmadl-Str. 15
3100 St. Pölten
Tel.: +43 2742 90855-11
Fax: +43 2742 90855-22
[email protected]

Czech Republic
Wöhler Bohemia s.r.o.
Za Naspern 1993
393 01 Pelhrimov
Tel.: +420 565 323 076
Fax: +420 565 323 078
[email protected]

France
Wöhler France SARL
17 A Impasse de Grousset
31590 Lavalette
Tel.: +33 5 61 52 40 39
Fax: +33 5 62 27 11 31
[email protected]
www.woehler.fr

Your contact:

WOHLER Logo

Documents / Resources

| WOHLER Indoor Air Quality Software [pdf] User Guide
Indoor Air Quality Software, Air Quality Software, Quality Software, Software
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

WOHLER User Manuals

Related Manuals