GUDE 94636 Combined submersible pump Instructions

June 5, 2024
Gude

GUDE 94636 Combined submersible pump

GUDE-94636-Combined-submersible-
pump-PRODUCT

DELIVERED ITEMS

GUDE-94636-Combined-submersible-pump-
FIG-2

Service connection

GUDE-94636-Combined-submersible-pump-
FIG-3 GUDE-94636-Combined-submersible-pump-
FIG-4

Starting-up the machine

GUDE-94636-Combined-submersible-pump-
FIG-5 GUDE-94636-Combined-submersible-pump-
FIG-6

Engine protection

GUDE-94636-Combined-submersible-pump-
FIG-7

Automatic Operation

GUDE-94636-Combined-submersible-pump-
FIG-8

Non-Stop Operation

GUDE-94636-Combined-submersible-pump-
FIG-9

Transport / Storage

GUDE-94636-Combined-submersible-pump-
FIG-10

Technical Data

Combined submersible pump GS 750 3IN1
Art. No 94636
Service connection 230 V~50Hz
Rated input 750 W
Max. immersion 7 m
Max. head of delivery 7,5 m
Max. delivered quantity 13.500 l/h
Max. suction 1 – 23 mm
Max. Water temperature 35 °C
Degree of protection IPX8
Weight 5 kg

IMPORTANT INSTRUCTIONS

Read and understand the operating instructions before using the appliance. Familiarise with the control elements and how to use the appliance properly. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties.

  • The operator is responsible for accidents or risks to third parties.
  • In case of any doubts about connection and operation refer please to our customer center
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction
  • concerning use of the appliance in a safe way and understand the hazards involved.
  • Children shall not play with the appliance.
  • Cleaning and user maintenance shall not be made by children without supervision.

Specified Conditions Of Use

The pump is solely used for drainage and for pumping into and out of containers in the house, garden, farm and agriculture and only for water. Respecting technical data and safety precautions. Do not use this product in any other way as stated for normal use. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages. Do not use pump at outside temperatures over 40 °C or under 0 °C

WARNING:

  • The pump is not suited for long-run operation (e.g. as a circulation pump in ponds or streams). When used in this manner, its service life is curtailed correspondingly. In these cases, then, use a time switch to secure sufficient idle periods between cycles of operation.
  • Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
  • Do not use the pump for drinking water!
  • The pump must not be used to pump waste water.

Emergency procedure

Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. If you seek help, state the following pieces of information:

  1. Accident site,
  2. Accident type,
  3. Number of injured persons,
  4. Injury type(s)

Safety Instructions

  • Do not grab the feeder cable, plunge the pump, lift or carry it while it is connected to the grid!
  • Unplug the device prior to submersion, upon termination of operation, in the course of defect removal and prior to performing maintenance procedures.
  • If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.).
  • The temperature of the drained liquid must not exceed +35 °C.
  • The pump must not in any case run without fillings.
  • Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
  • If the pump is used in ponds, wells, etc. and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed.
  • The user is responsible to third parties if pump (dum-ping stations, etc.) is used.
  • Check the cable and/or socket for damages before the appliance putting into operation.

Mains Connection

WARNING! Electric shock! There is a risk of an injury caused by electric shock! Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA).

  • Before putting into operation, a qualified electrician must check whether electric safety measures required are in place. Any national regulations in this regard must be complied with.
  • Electric connection to a socket.
  • Check the voltage. Technical data given on the type label must correspond with electric network voltage.
  • It is necessary to make sure the connecting socket was not near water and humidity and the plug was protected against humidity.
  • Only use splash proof extension cables approved for outdoor purposes.
  • Protect the feeder cable from excessive temperatures, oil and sharp edges.

Maintenance

IMPORTANT:
Unplug the machine before any work on it. 

  • Before using the appliance, perform a visual inspection at all times to make sure the power cord and the plug, in particular, are not damaged on the charger.
  • The appliance must not be used if damaged or safety equipment is defective. Replace any worn-out and damaged parts.
  • If the supply cord of this power tool is damaged,
  • it cannot be replaced, and the power tool shall be scrapped.
  • Repairs and works specified in these Instructions may only be performed by qualified authorized staff.
  • Use only original accessories and original spare parts.
  • Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to unforeseen accidents and injuries.
  • To ensure long service life of the pump seal we recommend rinsing the pump with clean water in regular intervals.

At winter storing, it is necessary to make sure there is no water in the appliance as the frost could damage the appliance. Prior to transportation, it is necessary to unplug the pump from the grid! The device has to be completely emptied and stored with frost-proof protection. Adhesion of mechanical seals can be prevented if you rinse the pump with appropriate oil (for example, with vegetable oil). If necessary, a list of spare parts can be found at www.guede.com.

Guarantee

Warranty period of 12 months applies to commercial use and 24 months applies to private use and commences on the day of purchase of the device. The guarantee solely covers inadequacies caused by material defects or manufacturing defects. Original payment voucher with the sales date needs to be submitted for any claim in the guarantee period. The guarantee does not cover any unauthorized use such as appliance overloading, use of violence, damage as a result of any unauthorized interference or caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee.
WOLPERTECH cannot be held responsible for damages incurred in consequence of unqualified installation or unskilled handling of the pump. The device has to be checked on a regular basis to ensure perfect functioning. Let us refer to the fact we do not assume any responsibility – according to standards in force – for damage eventually caused by our appliances in the below-mentioned cases:
Unprofessional repairs executed by unauthorized service centers;

  • Use in conflict with the designed purpose, or failure to observe the use as designed;
  • Pump overload with a continuous run;
  • Damage as a result of icing or any other fault caused by climatic influences;

Identical regulations apply for accessory parts. To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the ow-ner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).

Important information for the customer
Please be sure to know that returning the product in or after the warranty period must be made in the original packaging.

Service

Do you have any technical questions? Do you have a complaint? Do you require spare parts or an operating manual? You can get quick and unbureaucratic assistance in the Service section on the homepage of our service partner Güde GmbH & Co. KG (www. guede.com). Please help us to help you. In order to be able to identify your device in the case of a complaint, our service partner will require its serial number, article number, and year of manufacture. All this information can be found on the nameplate.

Tel.: +49 (0) 79 04 / 700-360
Fax: +49 (0) 79 04 / 700-51999
E-Mail: support@ts.guede.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals