Gude GH 15 EV Electric Heater Instruction Manual
- June 5, 2024
- Gude
Table of Contents
Gude GH 15 EV Electric Heater
We strive to continually improve our products. Therefore, to change specifications and pictures!
Unit
Electrical Heater 15 kW 400 V
A sturdy electrical heater Güde with a fan fitted.
Area of Use:
Electrical heaters are typically used in construction, ship building,
agriculture, car repair workshops, cooking, asseblies and anywhere where oil
and gas heaters are not permitted. .
Electrical Heater 15 kW 400 V
A sturdy electrical heater Güde with a fan fitted.
Area of Use:
Electrical heaters are typically used in construction, ship building,
agriculture, car repair workshops, cooking, assemblies and anywhere where oil
and gas heaters are not permitted.
Voltage: | 400 V/50 Hz/CEE 32 A |
---|---|
Maximum heating capacity: | 15 kW |
Heating degrees Weight: | 5 kW/10 kW/15 kW + Fan 14,5 kg |
Ordering No.: | 85014 |
Description Pic. A
- Carrying handle and a foot
- Protection grid
- Capacity degrees switch
- Thermostat controller
- Reset hole
Scope of Delivery
Electrical heater with a carrying handle enabling mobile use
Warranty
Warranty claims in accordance to the warranty certificate attached.
General Safety Instructions
Prior to the initial use of the unit, the operating instructions should be read completely. If in doubt with regard to connection and operation of the unit, consult the manufacturer (servicing department).
FOLLOW THE INSTRUCTIONS BELOW CAREFULLY IN ORDER TO SECURE A HIGH DEGREE OF SAFETY:
Always observe local construction and fire prevention regulations and the professional associations regulations when using the unit.
Material, function and quality has been extensively checked on before delivery. Nonetheless, the units may cause danger if used unprofessionally or by untrained persons contrary to the determination !
Caution!
- Check the unit for damages before every use .
- Observe the value of the mains voltage (400 V ~ 50 Hz).
- Please mind that hazards may arise when electrical instruments are used unprofessionally .
- Keep children away from electrical heaters. .
- Have any defective or damaged parts promptly replaced by a professional.
- Protect the unit from rain, water splashes and moisture.
- The authorised operators should check the units for any visible defects of control and safety devices and for the protection devices proper function .
- The supervision manager should be advised immediately any time when defects are found out.
- On finding defects that threaten the units safety, the operation of the units has to be interrupted immediately. Existing local regulations and respective electrical protections have to be observed when using the units.
- Mind the safety distance from flammable objects.
- Unobstructed air suction and output have to be guaranteed at any time.
- The air outlet should not be narrowed or equipped with tubes and hoses.
- Never put foreign objects in the units.
- Never cover up the units in operation.
- The safety devices should not be bridged over or blocked .
- The units should not be operated directly below the wallmounted socket.
- The units should not be exposed to a direct stream of water, such as from a high-pressure cleaner.
- Water should never intrude in the units.
- Units should not be installed and operated in the environment of the fire and explosion hazards..
- Units should never be installed and operated in an atmosphere with oil, sulphur and salt content Protect all the electrical cables of the units from damage, fro damage by animals as well.
- The units are heating automatic instrument for industrial use varying from site to site. .
- The units awe electrically operated only and are designed to be used automatically, universally and free of any faults.
- The units are fitted with especially encased heating resistors, decreased noise featuring axial fans requiring minimum maintenance, protection thermostats and aftercooling thermostats, room thermostat socket and an electrical cable with protection contact.
- The units comply with fundamental requirements of safety and health safety given by respective EU provisions.
- The operation of the units is safe and easy.
- Among other, the units may be used for :
- Drying newly constructed buildings.
- Spotted heating of outdoor work areas or in halls and factory spaces not endangered by fire.
- Temporary or permanent heating of rooms
- Defrosting machines, vehicles and non-flammable goods on storage. Observation of respective safety regulations is essential
The unit is allowed for operation on mains with FI (stray current protection switch) .
Emergency Action
Apply the first aid adequate to the injury and get qualified medical assistance as quickly as possible. Protect the injured person from more accidents and calm him/her down.
Signs on Unit
Meaning of Symbols
Symbols shown below are used throughout this manual and/or on the unit:
Product Safety:
|
---|---
Product compliance with respective EU standards|
Bans:
**** | |
---|---|
neral ban (in combination with another pictograph) | Live parts |
**** | |
Do not use the unit in rain | Do not cover up |
Warning:
|
---|---
Warning/caution| Beware of hazardous voltage
|
Beware of hot surface| Do not use indoors!
|
**** Keeping distance|
Commands:
|
---|---
General mandatory sign| Read operating manual before use
Environment Protection:
|
---|---
Wastes to be disposed of in a professional manner not to harm the
environment.| Cardboard packaging to be collected for recycling.
|
**** Faulty and/or disposed of electrical/electronic appliances to be
collected by authorised salvage places.|
Verpackung:
|
---|---
Protect from moisture| Protect from moisture
|
Interseroh-Recycling|
Technische Daten:
|
---|---
connection| Max output
| ****
Blower power| Heat settings
|
weight|
Declaration of Conformity
The company
Güde GmbH & Co. KG
Birkichstrasse 6
D-74549 Wolpertshausen
Germany
hereby declares that the design and structure of the devices listed below and in designs marketed conforms to applicable basic requirements of the EU directives on safety and hygiene.
This declaration on conformity becomes void in case of a change to the device not consulted with us.
dentification of the devices:
GH 15 EV
Order No.:
85014
Date/signature of manufacturer: 28.02.2011
Information about signer:
he executive
Mr Arnold
Technical documentation
J. Bürkle FBL; QS
Applicable EU directives:
2006/95 EC
2004/108 EC
Harmonized standards used
EN 55014-1:2006
EN 55014-2:1997/+A1:2001/+A2:2008
EN 61000-3-12:2005
EN 61000-3-11:2000
EN 60335-2-30:2003+A1:2007
EN 60335-1:2002+A11,A1:2004+A12,A2:2006+A13:2008
EN 62233:2008
Harmonized standards used
Intertek Deutschland GmbH, Stangen Str. 1,
70771 Leinfelden-Echterdingen
Bestimmungsgemäße Verwendung
Assigned Use
Electrical heaters are used in construction, ship building, agriculture, car repair workshop, cooking and for assembly works and anywhere where oil or gas heaters are not permissible.
The manufacturer shall not be made liable for damages if general rules and this manual regulations are not observed.
Residual Hazards and Protective Action
Residual Hazards and Protective Action
Hazard | Description | Protective Action |
---|---|---|
Direct electrical | May result in an | Operate only on the |
contact | electrical shock | mains with stray |
current protection | ||
switch | ||
Indirect | May result in an | Operate only on the |
electrical | electrical shock | mains with stray |
contact | current protection | |
switch |
Thermal Residual Hazards
Hazard | Description | Protective Action |
---|---|---|
Burns, frostbites | A contact with protection grid and the unit case ,may cause | |
burns | Avoid the structural parts . |
Warranty
The warranty applies exclusively on material or production defects. For warranty claims, please submit an original proof of purchase with date of purchase indicated. The warranty does not cover unprofessional use, such as overloading, violent use, damage caused by third party or a thing. The warranty also does not cover failure to comply with the operation manual and normal wear and tear.
Emergency procedures
Administer first aid according to injury and call for qualified medical
assistance.
Protect injured person against other injuries and keep him/her in rest.
For reasons of potential injury, a first aid box according to DIN 13164 must be available on workplace. Replenish immediately material used from the first aid box. If you require medical assistance, give the following information:
- Place of accident
- Type of accident
- Number of injured persons
- Type of injury
Disposal
Disposal instructions are illustrated in the form of pictograms on the device or packaging. Description of the pictograms is given in “Identification” chapter.
Disposal of transport packaging
Packaging protects the device against damage during transport. Packaging
materials are usually selected according to their effect on environment and
disposal methods and can therefore be recycled.
Returning of the packaging back to circulation saves resources and costs for
packaging disposal.
Parts of the packaging (e.g. foil, styropor) may be dangerous for children.
Risk of suffocation!
Keep these parts of the packaging out of reach of children and dispose as soon
as possible.
Operator requirements
The operators must thoroughly read operation manual before use.
Qualification
Except for thorough training by an expert for use of the device, no special qualification is required.
Minimum age
The device may be operated by persons over 16 years of age. An exception is use by younger person if the use takes place under supervision of an adult trainer in the course of ed ucation.
Training
Use of the device requires corresponding guidance by an expert or operation manual only. No special training is required.
Service
Any technical questions? Complaint? Do you need spare parts or operation
manual?
Go to our website www.guede.com and the section Service will help you quickly
and without bureaucracy. Please, help us to help you. In order to identify
your device in case of complaint, please indicate serial number, order number
and year of manufacture. All information is available on the product label. To
have all information always at hand, put them down.
Serial number:
Order number:
Year of manufacture:
Phone: +49 (0) 79 04 / 700-360
Fax: +49 (0) 79 04 / 700-51999
E-Mail:support@ts.guede.com
Transportation and Storage
The unit may be carried over using the carrying handle .
If the units are out of use, store them in a dry locked room.
Bedienung (Abb. B + C)
Stecken Sie das Netzkabel in eine geeignete Steckdose ein.
Achten Sie auf geeignete Absicherung Ihres Stromnetzes.
Operation (pic. C):
Use the thermostatic regulator (pic. A/4) to set the required temperature.
The function switch (pic. A/3) has
5 switching levels:
| Off
---|---
| Fan
| 1 heating level – 1/3rd performance
| 2 heating level – 2/3rd performance
| 3 heating level – 3/3rd performance
Thermostat (pic. C) setting
Set the thermostat (pic. A/4) to the medium switch-off temperature.
Set the electric heater to the full heating power (pic. A/3) and let it heat until it is switched off by the thermostat.
Switch the electric heater off and measure the temperature in the room.
If the room temperature is too low, turn the thermostat regulator (pic. A/4) more to the right and switch the heater on again.
If the room temperature is too high, turn the thermostat (pic. A/4) more to the left, let the room cool down and then switch the heater on again.
Keep repeating the process until the required switch-off temperature is achieved.
Reset hole (pic. A/5)
There is a reset button (pic. A/5) on the thermostat regulator (pic. A/4).
If the appliance is overheated, working of the electric heater is stopped by the thermal fuse.
In such a case, the thermal fuse must be manually reset.
Unplug the electric heater before thermal fuse resetting.
Use a small round rod, etc. to press into the reset hole.
Attention: For the first commissioning of the electrical heater, it can sometimes be an unpleasant odor which is completely harmless and completely disappears with increasing operating time.Birkichstrasse 6
74549 Wolpertshausen Deutschland
Tel.: +49-(0)7904/700-0
Fax.: +49-(0)7904/700-250
Email: info@guede.com
Documents / Resources
| Gude
GH 15 EV Electric
Heater
[pdf] Instruction Manual
GH 15 EV, Electric Heater, GH 15 EV Electric Heater, Heater
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>