baseaire AirWerx 90X Energy Star Dehumidifier User Manual
- June 5, 2024
- BaseAire
Table of Contents
- baseaire AirWerx 90X Energy Star Dehumidifier
- Safety Notes
- Electrical Supply
- Installation
- Key Functions
- Indicator Lights
- Remote Control Instructions
- Operating Instructions
- Airwerx 90X Diagram
- Maintenance
- Ducting Installation
- AirWerx 90X Spare Parts
- Troubleshooting
- Limited Warranty
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
baseaire AirWerx 90X Energy Star Dehumidifier
Warranty Registration
Congratulations on purchasing a new AirWerx 90X Dehumidifier. Your new
dehumidifier comes with an extensive warranty plan. To register, simply fill
in and return the warranty card provided in your dehumidifier box.
Be sure to note your dehumidifier serial number as you will need it for
registration.
Safety Notes
-
The AirWerx Series Dehumidifier must always be connected using a grounded electrical connection (as required for all electrical appliances). If non-grounded wiring is used, all liability reverts to the owner and the warranty is voided.
-
AirWerx Dehumidifiers should only be maintained and repaired by a qualified technician.
-
AirWerx Dehumidifiers are only intended for operation when oriented with the unit sitting on its feet and level. Operating the unit in any other orientation could allow water to flood electrical
components. -
Always unplug the dehumidifier before moving it to another location.
-
If there is a chance that water flooded the dehumidifier, it should be opened and allowed to dry thoroughly before reconnecting to electrical power and restarting.
-
To ensure proper operation, neither the inlet nor discharge should be positioned against a wall. The inlet requires a minimum of 12″ clearance and the discharge requires a minimum of 36″clearance.
-
The best option for proper diffusion of air throughout the room is to have the discharge blowing away from a wall and the inlet pulling air in parallel to a wall.
-
Do not insert your fingers or any object into the inlet or discharge.
-
All work on the dehumidifier should be done with the unit “off” and unplugged.
-
Do not use water to clean the exterior. To clean unit, unplug from power, then use a damp cloth to wipe the exterior.
-
Do not stand on the machine or use it as a device to hang clothes.
Identification
For future reference, write down the model, serial number, and date of purchase for your dehumidifier. This is extremely helpful if you need to seek assistance in the future. The data label on the side of your unit has the key characteristics of your specific unit.
For additional questions concerning your dehumidifier, the following options are available:
- Contact your installing contractor
- E-mail: sales@baseaire.com
Electrical Supply
Power Supply: 115 V, 60 Hz AC, Single Phase
Outlet Requirement: 3-Prong, GFI
Circuit Protector: 15 Amp
WARNING: 240 Volts AC may cause serious injury from electric shock. To reduce the risk of injury:
- Disconnect electrical power before servicing.
- Only plug unit into grounded electrical circuit.
- Do not use an extension cord.
- Do not use a plug adapter.
Principle of Operation
The AirWerx Series Dehumidifier utilizes its integral humidistat to monitor the conditioned space. When the relative humidity goes above the selected set point, the dehumidifier will energize. Air is drawn across an evaporator coil, which is cooler than the dew point of air. This means moisture will condense out of the air. The air is then reheated through the condenser coil and distributed back into the room.
Installation
The area to be controlled should be sealed with a vapor barrier. If the unit is installed in a crawlspace, all vents should be sealed.
WARNING: Do not install your dehumidifier in a corrosive environment. Some liquid vapor barriers dry via “solvent evaporation”. Always make sure that barrier is completely dry and area is thoroughly ventilated before installing dehumidifier.
Step #1: Place the dehumidifier on a level surface.
Do not place unit directly on vapor barrier. For example, use blocks or pavers
to create a level surface. If the unit is handled in such a manner that the
compressor did not remain in the upright position, you will need to place ii
on a level surface and wait a minimum of 2 hours before turning the unit “on”.
Step #2: Set Up Drain Line
The included drain line attaches to unit via a compression type fitting on the
discharge end of the unit.
To attach drain line, remove the compression nut and slide it over the end of
the house to be attached to unit. Side compression nut side of house over the
insert on the compression fitting completely.
tighten compression nut.
Key Functions
-
Power Key
Use this button to turn the dehumidifier on and off. Press once to turn the machine on. You will
hear two beeps and the O light will illuminate green. Press the power button a second time and you
will hear one beep as the machine shuts down. Note that there is a one minute fan delay on
shutdown. -
Arrow Buttons
Use the up and down arrow buttons to set the desired humidity setpoint on the display screen.
88 The setpoint can be any number between 36-90%. Creating a setpoint means that when the
indoor humidity is lower than the set point, the machine will stop automatically. Conversely, when
the indoor humidity is higher than the set level, the unit will operate.
NOTE: The humidity levels displayed are approximate only (+/-56) -
Continuous Mode
To switch into continuous mode, set the humidity below 36%. At this point the Cont. light should illuminate green on the display board to indicate you have successfully switched to continuous mode. The display screen will show “C0”. When set to continuous, the dehumidifier will run constantly, regardless of the humidity level. To stop the dehumidifier from running, turn the unit off or switch back to normal humidistat operation. To switch back to normal humidistat operation simply move the setpoint above 36%. -
Central Control
This mode is not applicable on the AirWerx 90x.The Central Control light should off at all times when not connected to the AC. -
Manual Drain Button
For extended storage or movement of the machine, press the “Drain” button to remove water from the integral pump’s reservoir. -
Pump Trouble Warning
When the pump reservoir water level is too high, the high water sensor will activate to prevent overflow. When this occurs, the dehumidifier will stop the compressor automatically and the display will show “E4” error. After a 1 minute delay, the fan motor will turn off and the machine wll not operate until the problem is resolved. To reset the unit after an “E4” error, check the pump to verify it is functioning. then unplug the unit for two minutes. -
Auxillary Terminals A5/A6
The A5/A6 on the terminal strip can be used as a safety switch for external condensate pumps. It should be set to N/o (normally open) at the dehumidifier. If an E4 error codes, switch the wiring to N/C (normally closed).
Indicator Lights
-
Humidity Display Screen The display screen has two functions:
-
When the unit is powered on, it shows the humidity of the space.
-
While setting the desi After a brief delay, the display will revert to the current humidity level. ed humidity level, the screen will sh the humidity.
-
Power Indicator Light
This light indicates that the unit is properly powered on and ready to operate. Always make sure the is “off” prior to performing any service.
When the power light is blinking, it means that the unit has reached the humidity setpoint. -
Continuous Mode / Auto Defrost Light
When this light illuminates green, it indicates that the dehumidifier is set to continuous operation mode.
When the light glows red, it means the unit is in auto defrost mode and clearing the evaporator coil of any ice build up. -
Compressor Light
When the compressor light glows red, it indicates the compressor has been initiated but is currently warming up.
Comp Once the compressor light switches to green, it indicates the compressor is in working status.
Remote Control Instructions
AirWerx Dehumidifiers can be controlled using an optional remote accessory.
The AirWerx Remote Control connects to your Airwerx Series Dehumidifier via a
25′ CAT 5 cable. The remote control contains an integrated sensor which gives
you multiple options for remotely controlling your unit, in addition to
monitoring the conditions surrounding the dehumidifier.
One application for the remote control is to install the dehumidifier in one
room with the conditioned air ducted into a second room that contains the
remote. For example, the dehumidifier could be installed in a laundry room and
ducted into a living room. The remote would then be mounted in the living room
so the remote sensor can control the humidity and provide easy controls for
the user.
Another useful application for the remote control is if the dehumidifier is in
area that’s difficult to access on a regular basis. For instance, if your
dehumidifier is installed in your crawl space, the remote could be mounted in
your living space or garage. This provides you with an easy way to monitor the
dehumidifier.
-
On/Off( Power) Button (I)
Press the on/off button and the machine will start running (two beeps). Press the button again to the turn the machine off. -
Up Button .&. /Down Button T
Use the Up and Down arrow buttons to adjust the humidity level. -
ModeM
Use the mode button to switch between dehumidification and a ducted application.
The @ symbol on the display board indicates the sensor on the remote control is being utilized. The • symbol on the display board indicates the sensor on the dehumidifier is being utilized. -
Temperature T
Press the temperature button to display the current temperature on the screen. Press the button again to turn off the display. -
Continuous c
Press this button to switch the unit into continuous mode. cont. will appear on the display to indicate continuous mode. -
Drain Pump
Use this button if the unit will not be in use for an extended of time. Pressing the drain pump button will remove water from the pump reservoir, so the unit can safely moved or stored.
NOTE: The symbols mentioned above will only appear when the dehumidifier is powered on.
Operating Instructions
-
Start the machine
Press the power key to turn the machine on. -
Adjust Settings
Use the up and down arrow keys to adjust your desired setpoint ( typically 50-55%) . -
Stop the Machine
Press the power key again and the machine will stop. Note the fan will continue to operate for 1 minute after the unit has shut off.
NOTE: Do not disconnect the power cord to force the unit to stop. Always use the power button. -
Water Drainage
The AirWerx 90X has both automatic and manual draining. During normal operation, the AirWerx 90X will automatically drain as required. If you would like to move or store the machine, you may press the drain button to drain the water from the pump reservoir. The drain will operate for 15 seconds each time the button is pushed. It may be necessary to push the drain button more than once to completely empty the reservoir.
Airwerx 90X Diagram
Maintenance
WARNING: Always unplug the unit before doing any maintenance.
Condensate Pump
Your AirWerx 90X is equipped with an integral condensate pump designed to pump
water from your dehumidifier out to the desired drain. This pump requires
routine maintenance that is nor covered by your 1-year parts warranty. Only a
defective pump will be repaired or replaced during the warranty period.
Preventative Maintenance
As with all pumps, preventative maintenance is necessary to prevent issues
from dirt and slime that may accumulate in the drain system. This includes the
drain pan, hose to the condensate pump, pump reservoir, pump head float
assembly, and discharge tubing,
At least once per year, clean your pump system
-
Cleaning the machine body
Use a soft damp cloth to clean the exterior of unit. Do not use any soap or solvents. -
Coil the filter
- Unplug the unit.
- Slide out the filter.
- Clean the filter mesh by vacuuming or washing with warm water ( no soap or solvents).
- Be sure filter is completely dry before restarting the unit.
-
Coil Maintenance
- Once per year, clean the coils with an approved coil cleaner.
- Coil cleaner should be a self-rinsing, foaming cleaner such as WEB® Coil Cleaner.
-
Electrical Access
- Unscrew the 4 screws on the side panel to access the control board. : ·. –
-
Pump maintenance
- Unscrew the 4 screw on the pump access panel.
- Remove the screw on the pump.
- Undo the 3 pump quick connects.
- Insert a flathead screwdriver into the notch on the side of the pump to help you gently lift the pump off it’s reservoir remains attached to the unit.
-
Cleaning/Didinfecting the Pump
Basic Cleaning (Complete about once a year, depending on environment)- Open the end cap on the filter side of the unit. Press the frain the resevoir.
- Disconnect power to the dehumifidier.
- Mix a 16 oz solution of either (1 oz bleach + 15 oz water) OR (4 oz white vinegar+ 12 oz water).
- Pour solution into the drain tray at the base of the coils. If any cleaning solutions gets on coils, flush with water.
- Allow solution to soak for 15 minutes.
- Reconnect the dehumidifier to power.
- Fill the reservoir with water and flush/cycle the pump at least two times.
- If drain line is still filled with debris, repeat process. If still not cleaned, move on to Advanced Cleaning.
- Reassemble unit, unless moving on to advanced cleaning.
Advanced Cleaning (Complete as needed)
-
Press the drain button to drain the water from the reservoir (A wet-dry vacuum or towels can be used to remove any remaining water).
-
Unplug the dehumidifier and remove the cover so you have access to the pump.
-
Remove the pump head from the reservoir by unscrewing the screw. Wipe reservoir clean with a paper towel.
-
Mix a 16 oz solution of either (1 oz bleach + 15 oz water) OR (4 oz white vinegar+ 12 oz water).
-
Fill the pump reservoir with cleaning solution.
-
Reassemble pump, then use manual drain button to flush mixture through discharge tubing.?. Pour same cleaning solution slowly into drain tray under evaporator coils and let it clean hose from pan to pump. This process can be stopped when the pump energizes one time.
NOTE: If you get any of the cleaning solution on the coils, flush with water. -
Pour sufficient clean water through drain pan to allow the pump to turn on twice.
-
Reassemble the unit and return it to operational status.
Dehumidifier Storage
If the unit will be stored for an extended period of time, complete the following steps:
- Turn off the unit and allow to dry.
- Wrap and secure the power cord.
- Cover the filter mesh.
- Store in a clean, dry space.
Ducted Applications
Ducting the dehumidifier allows the unit to be in one room while conditioning
an adjacent room. The inleV return collar ( optional accessory, PN: W-103) is
designed for 12″ flex ducting while the supplt grille is designed for 6″ flex
ducting.
Be sure to secure the ducting with tie wrap. Also, keep in mind, that the
supply ducting can be screwed into an adapter if necessary.
Ducting Installation
- Maximum total length of duct run= 1 O’
- Maximum length if only ducting inlet or outlet= 6′
- To connect 12″return ducting. it may be helpful to:
- Remove inlet grille from end cap.
- Connect duct to inlet grille.
- Reconnect inlet grille to end cap.
Note: The supply duct adapter is standard on all units. Return duct is an optional accessory.
-
Removing Duct Adapter
If it is necessary to remove the adapter, place hand at bottom of the adapter and use your fingers to pull out and down. This will remove the cover hooks from the machine. -
Installing Duct Adapter
To install adapter, line duct up with holes on the side of unit push up from the base of the adapter. -
Flex Duct Installation
Rotate the flex duct counter-clockwise. -
Flex Duct Removal
Rotate flex duct clockwise or remove wire tie.
AirWerx 90X Spare Parts
__
Pa r t #
| All AirWerx Models-Parts
Description
| __
Pa r t #
| AirWerx SOX-Parts
Description
---|---|---|---
A 100| Remote Control Package ( cabe+remote)| A 900| Fan Motor
A 101| Remote Control| A 901| Complete Fan Assembly
A 102| Remote Control Cable, 26′| A 902| Fan Capacitor
A 103| Return Duct Collar Accessory| A 903| Compressor
A 106| Duct Kit Assembly ( W 103+ W 100)| A-904| Compressor Capactor
A 107| Fexible Supply Duct, 72″| A-905| Coil Assembly
A 108| Main Control Board| A-906| Hot Gas Bypass Coil
A 109| Display Board| A-907| Condensate Pump Assembly
A 110
__
Part#
| RH/Temperature Sensor
AirWerx SOX-Filters
Descrption
| A-908 A-909
A-910
| RH/Temperature Sensor Cable Display cable
CAT 5 Prot Internal Cable
A-915
A-916
| Prefilter
Filter Assembly ( Cassette+Prefilter)
| A 913| Foot, adjustable
A-917| MERV 8 Filter| |
A-918| HEPA Flter| |
A-919| Carbon Filter| |
Troubleshooting
Symptom | Cause | Solution |
---|
Machine Won’t Run
| ****
Power Supply
| Verify that there is power to the outlet and that the plug is properly installed in outlet.
Room Temperature Over 105°F (Display HI) or Below 33°F(Display LO)
| The unit id outside the operating temperature range. Modify the room conditions so the temperature is between 33-105°F and operation will commence.
Low Air Flow
| ****
Air Filter is Clogged
| Clean the filter mesh according to instructions listed in manual.
Air Inlet or Outlet is Blocked.| Clear the blockage from inlet or outlet.
Loud Noise
| Machine Is Not level| Move the dehumidifier to flat, firm ground.
Filter Mesh is Blocked| Clean the filter mesh according to instructions listed
in manual.
Trouble Code: E1
| ****
E1=Humidity Sensor Issues
| Check to ensure that wire is connected at both ends. If no issues are visible, the sensor may be faulty.
Trouble Code: HI or LO
| ****
Room Temperature Over 105°F or Below33°F( Display LO)
| The unit is outside the operating temperature range. Modify the room conditions so the temperature is between 33-105°F and operation will commence. If room conditions are within temperature range, replace the defective sensor.
Pump Alarm- Trouble Code E4
If a pump alarm is shown on the display, complete the following steps:
-
Reset the unit by disconnecting the power cord and then reconnecting it.
NOTE: UNIT WILL NOT FUNCTION UNTIL ERROR CODE HAS BEEN CLEARED. -
Manually check to see if pump is operational by pressing the drain button. Check if the pump energizes and de-energizes properly. Additionally, check to see if any water purged from the system.
-
If you haven’t cleaned the system recently, check the discharge line for an obstruction, then clean the balance of the pump system (see “Maintenance” on page 8 for details).
-
Replace the houses and/or pump, if maintenance alone isn’t sufficient.
Limited Warranty
This limited warranty starts from the date of purchase. BASEAIRE warrants to
the original purchaser that this BASEAIRE product is free from manufacturing
defects in material or workmanship for the limited warranty period of:
Six (6) Month parts and labor. This includes the shipments charges for
replacement parts or unit.
One (1) year parts and labor. This does not include the shipment charge to
send the defective product back to be repaired or replaced.
Three (3) years parts and labor on Refrigeration System ONLY (Compressor,
Condenser, and evaporator). Transportation cost, not included
Five (5) years parts on Refrigeration System ONLY(Compressor, Condenser, and
evaporator).
Transportation cost, not included
This limited warranty is valid only on products purchased from the
manufacturer or BASEAIRE authorized dealer and operated, installed, and
maintained according to the instructions included in this user guide or
furnished with the product. BaseAire will not provide in-home service during
or after the warranty period. You may be responsible for the shipping charge
to bring the product to the manufacturer for service.
To receive warranty service, the purchaser must contact BASEAIRE at
1-888-641-8862 or sales@baseaire.com. A
proof of purchase or order number is required to receive warranty service.
During the applicable warranty period, a product will be repaired or replaced
at the sole option of BASEAIRE.
Limited Warranty Exclusions
This limited warranty covers manufacturing defects in materials or workmanship
encountered in normal household, commercial or noncommercial use of this
product and shall not cover the following:
- Damage occurs in uses for which this product was not intended for.
- Damage caused by unauthorized modification or alteration of the product.
- Cosmetic damage including scratches, dents, chips, and other damage to the product’s finishes.
- Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature.
- Damage caused by incorrect electrical line current, voltage, fluctuations, and surges.
- Damage caused by failure to perform proper maintenance of the product.
The use of this product in SPA or a room with OUTDOOR POOL invalidate or voids limited warranty.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>