AERAMAX AM3 PRO Air Quality Control System Installation Guide

June 4, 2024
AERAMAX

AERAMAX logo INSTALLATION GUIDE
AeraMax® PRO Air Quality Control System: AM IIIAERAMAX AM3 PRO Air Quality
Control System

Please read the instructions carefully before installing the unit

KEY

AERAMAX AM3 PRO Air Quality Control System parts

  1. Access Panel
  2. Filters
  3. Filter frame
  4. Main Assembly
  5. Power Switch
  6. Access panel latch
  7. Access panel lock
  8. Rear housing assembly
  9. Control panel
  10. Filter frame window

SAFETY

WARNING: To avoid the risk of electrocution confirm the electrical supply has been disconnected or switched off before beginning any installation work.
Confirm no electrical wiring, utility pipes, or ductwork is located directly behind the installation/drilling area.
On a stud wall, it is strongly recommended at least 2 mounting anchors for the air purifier be mounted to an existing stud.
TOOLS REQUIRED FOR INSTALLATION

  • Electric drill, drill bits (not included)
  • 2 Phillips and # 2 Flat Head screwdrivers (not included)

  • Wire nuts (not included)
  • Level (not included)
  • Mounting template (included)

PARTS PROVIDED FOR INSTALLATION

  • Drywall Anchors – 10mm OD
  • Pan Head Phillips Screws

PRODUCT INSTALLATION GUIDELINES

Place the mounting template provided on the wall where the air purifier is to be installed. If air purifier is being mounted high on the wall make sure the top edge of the unit is positioned at least 8” inches (21 cm) below the ceiling to allow for filter replacement (see Fig 2).
AERAMAX AM3 PRO Air Quality Control System fig Americans with Disabilities Act (ADA): Be sure to follow all ADA guidelines pertaining to “Objects protruding into a circulation path.” For more information visit www.ada.gov.

MOUNTING REAR HOUSING AND MAIN ASSEMBLY

Test the electrical outlet box first to ensure rated power requirements are met before beginning installation.
Remove air purifier from its shipping carton and remove all packing material.

Place the air purifier face up on a flat, stable work surface. Open the access panel by pressing in latches on each side of the unit (Fig 3).AERAMAX AM3
PRO Air Quality Control System fig 1

Open the access panel and remove filter assembly by pulling out on top of side edges of the frame, then lifting. NOTE: remove all plastic wrap from filters (Fig 4).AERAMAX AM3 PRO Air Quality Control System fig
3

At the location of the two upper housing screws (Fig 5), insert a flat head screwdriver and gently twist to the release tab as shown in Fig 7. This will disconnect the main housing
assembly from the rear housing assembly. AERAMAX AM3 PRO Air Quality Control
System fig 2

Disconnect the main housing assembly from the rear housing assembly. Separate the main housing from the rear housing. Lift main housing assembly away from rear mounting housing (Fig 8).

REAR HOUSING INSTALLATION & WIRING
Reference rear housing and locate desired mounting location. Again, it is strongly recommended at least 2 mounting anchors for the air purifier be mounted to an existing stud.

Using provided template ensure the electrical outlet box is located behind cable hole (A) in the Rear Housing assembly (Fig 9). Drill holes and place anchors in the wall. If mounting on concrete, cinder block or brick-type walls route the wires through the “punch-out” hole marked (B) in Fig 9

Check for washers at all mounting screw locations (Fig 10). Pull wires from the electrical outlet box through the hole in the rear housing. Align housing over anchors and securely install all mounting screws.AERAMAX AM3 PRO Air
Quality Control System fig 6

Attach wires from the electrical outlet box to wires located inside the rear housing using wire nuts. Match up line (black) and neutral (white) wires (Fig 11). Make sure
all connections are made in accordance with federal, state and local codes and regulations.

MAIN ASSEMBLY INSTALLATION

WARNING: To avoid the risk of electrocution confirm the electrical supply has been disconnected or switched off before continuing any installation work.
AERAMAX AM3 PRO Air Quality Control System fig 7The power connector (B, in Fig 12) will carry power from the rear housing to the main housing once the assemblies are fully seated. The main assembly will attach to the rear housing assembly by the four screws previously removed (Fig 5 & 6). Two snap hooks (A, in Fig 12) will hold the main and rear assemblies together until the screws can be installed.AERAMAX
AM3 PRO Air Quality Control System fig 8

Carefully align the main assembly with the rear housing assembly. Slowly press into place until the snap is heard, and there is no gap between the assemblies (Fig 13). The unit should now support its own weight.AERAMAX AM3 PRO Air
Quality Control System fig 9

Install four screws (previously removed) to secure main assembly to the rear housing assembly (Fig 14 & 15).

RE-INSTALLING FILTERS

IMPORTANT: Make sure all plastic wrap is removed from the filters.
Make sure filters are in the correct order – pre-filter / carbon filter / HEPA filter – and inserted into the filter frame (Fig 16).

IMPORTANT: Make sure filter detection area aligns with window in filter frame (Fig 17). Open the front panel by pressing latches on both sides of the unit. Allow the door to open fully. Insert filters
IMPORTANT: make sure the filter detection window is aligned in the upper right corner (Fig 18).AERAMAX AM3 PRO Air Quality Control System fig
15

Close the front panel by pressing firmly until both sides’ latch is closed (Fig 19).AERAMAX AM3 PRO Air Quality Control System fig
12Once the unit is closed re-establish power. Lights on the control panel will be visible through the lens, indicating the unit is operational (Fig 20). The power light indicator
will flash once a second.
LOCKING ACCESS PANEL
To restrict access to the control panel and filters the unit can be locked. To lock, insert the key provided and rotate clockwise ¼ turn (Fig 21).

Fellowes, Inc.
1789 Norwood Ave
Itasca, Illinois 60143-1095 USA
630-893-1600
1-800-477-7940
Product Support: 1-800-945-4545
www.aeramaxpro.com
©2014 Fellowes, Inc. Part No. 408530 Rev B

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>