Hammer drill | SBM 1050 E |
---|---|
Art. No | 58113 |
Service connection | 230 V ~ 50 Hz |
Rated input | 710 W |
No-load speed | |
1 | 0-1100 min-1 |
2 | 0-2800 min-1 |
Drilling capacity max.
Concrete
Steel plate| 13 mm
13 mm
Wood| 25 mm
Drill chuck range| 2 – 13 mm
Chuck neck diameter| 43 mm
Weight| 2,3 kg
Noise details|
Sound pressure level LpA| 93 dB(A)
Sound power level LWA| 104 dB(A)
Measured according to EN 60745; Uncertainty K = 3 dB (A)
Wear ear protectors!
Vibration details
Vibration total values (triaxial vector sum) determined according to EN
60745:
Drilling into metal: Vibration emission value ah, D| 5,5 m/s²
Impact drilling into concrete: Vibra- tion emission value ah,ID| 10,6 m/s²
Uncertainty K = 1,5 m/s2
WARNING: The vibration emission level will vary because of the ways in
which a power tool can be used and may increase above the level given in this
information sheet.
The vibration emission level may be used to compare one tool with another.
It may be used for a preliminary assessment of exposure.
An accurate estimate of the vibratory load should also take into account the
times when the tool is shut down or when it is running but not actually in
use. This may significantly reduce the vibratory load over the total working
period. Identify additional safety measures to protect the operator from the
effects of vibration such as: maintaining the tool and the accessories,
keeping the hands warm, and organization of work patterns.
Read and understand the operating instructions before using the appliance.
Familiarise yourself with the control elements and how to use the appliance
properly. Abide by all the safety measures stated in the service manual. Act
responsibly toward third parties.
The operator is responsible for accidents or risks to third parties.
Persons over 16 years of age can only work on the appliance. An exception
includes youngsters trained in order to reach knowledge under the supervision
of the trainer during occupational education.
In case of any doubts about connection and operation refer please to our
customer center
Specified Conditions Of Use
The percussion drill can be universally used for drilling and percussion
drilling.
Do not use this product in any other way as stated for normal use. Not
observing general regulations in force and instructions from this manual does
not make the manufacturer liable for damages.
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. If you seek help, state the following pieces of information:
- Accident site,
- Accident type,
- Number of injured persons,
- Injury type(s)
Symbols
WARNING/CAUTION!
WARNING – Read the operating instructions to reduce the risk of injury.
Wear eye protective goggles! Wear ear protectors!
Unplug the machine before any work on it.
**** Class II tool.
CE marking
Any damaged or disposed of electric or electronic devices must be delivered to
appropriate collection centers.
WARNING Read all safety warnings and all instructions. Failure to follow
the warnings and instructions may result in electric shock, fire, and/or
serious injury.
Save all warnings and instructions for future reference.
Drill safety warnings
Wear ear protectors when impact drilling. Exposure to noise can cause
hearing loss.
Use auxiliary handle(s), if supplied with the tool. Loss of control can
cause personal injury.
Hold power tool by insulated gripping surfaces, when performing an operation
where the cutting accessory may contact hidden wiring or its own cord. Cutting
accessory contacting a „live“ wire may make exposed metal parts of the power
tool „live“ and could give the operator an electric shock.
Additional Safety and Working Instructions
Use protective equipment. Always wear safety glasses when working with the
machine. The use of protective clothing is recommended, such as dust masks,
protective gloves, sturdy non-slip footwear, and ear defenders.
The dust produced when using this tool may be harmful to health. Do not inhale
the dust. Use a dust absorption system and wear a suitable dust protection
mask.
Remove deposited dust thoroughly, e.g. with a vacuum cleaner.
Always keep the connection cable from the working area of the device. Always
guide the cable backward, away from the device!
Do not machine any materials that present a danger to health (e.g. asbestos).
When working on walls ceilings, or floors, take care to avoid electric cables
and gas or water pipes. Clamp your workpiece with a clamping device. Unclamped
workpieces can cause severe injury and damage.
Please turn the device immediately off when the tool used gets blocked! Do not
turn the device on again when the tool is still blocked. This could cause a
bounce back with a high reaction moment. Determine and remove the cause of the
blocking of the tool used while respecting the safety instructions.
The possible causes may be:
- it is tilted in the workpiece to be machined
- it has pierced through the material to be machined
- the power tool is overloaded
Do not reach into the machine while it is running.
Chips and splinters must not be removed while the machine is running.
WARNING! Danger of burns
The insertion tool may become hot during use.
- when changing tools
- when setting the device down
The appliance must not be used if damaged or safety equipment is defective.
Replace any worn-out and damaged parts.
Do not use the device near flammable liquids or gases. Risk of fire and
explosion in case of short circuit. Do not let any metal parts reach the
airing slots – the danger of a short circuit!
Mains Connection
Operation is only allowed with a safety switch against stray current (RCD
max. stray current of 30mA).
Connect only to single-phase AC system voltage as indicated on the rating
plate. It is also possible to connect to sockets without an earthing contact
as the design conforms to safety class II.
Only plug in when the machine is switched off.
Maintenance
Unplug the machine before any work on it.
Repairs and works specified in these Instructions may only be performed by
qualified authorized staff. Use only original accessories and original spare
parts.
Keep the device, in particular the air vents, clean at all times. Never spray
water on the device’s body!
Do not clean the plastics with solvents, flammable or toxic fluids. For
cleaning, use a damp cloth only.
Caution! If the power cord of the appliance gets damaged, it must be
replaced by the manufacturer or its customer service or a similarly qualified
person to avoid danger.
Only a regularly maintained and treated appliance can serve as a satisfactory
aid. Insufficient maintenance and care can lead to unforeseen accidents and
injuries.
If necessary, a list of spare parts can be found at
www.guede.com.
Translation of the EC-Declaration of Conformity
We, hereby declare the conception and construction of the below-mentioned
appliances correspond – at the type of construction being launched – to the
appropriate basic safety and hygienic requirements of EC Directives.
In case of any change to the appliance not discussed with us, the Declaration
expires.
# 58113 SBM 1050 E Notify ed Body Name: TUV SUD Product Service GmbH
No: 0123 Adress: Zertifizierstelle.Ridlerstrabe 65.80339
Munchen.Germany
Type Ex. Cert.-No.: M6A 1511 55256 452
-
97/68/EC_
Emission No.: -
2000/14/EC_2005/88/EC
Method of compliance assessment
Annex V
Wolpertshausen, 19.04.2016
**Helmut Arnold
Güde GmbH & Co. KG, Birkichstraße 6, 74549 Wolpertshausen, Germany
Joachim Bürkle
GÜDE GmbH & Co. KG, Birkichstraße 6, 74549 Wolpertshausen, Germany
Bevollmächtigt die technischen Unterlagen zusammenzustellen.
Authorized to compile the technical file
Harmonised standards used
EN 61029-1:2009/A11:2010
EN 61029-2-1:2012
AfPS GS 2014:01 PAK
EN 55014-1:2006/A2:2011
EN 55014-2:1997/A2:2008
EN 61000-3-2:2014
EN 61000-3-11:2000
Guaranteed sound power level
LWA dB (A) 108
Measured sound power level
LWA dB (A) 105
**