EPEVER RTU 4G GPRS Transmission Terminal Instruction Manual
- June 5, 2024
- EPEVER
Table of Contents
EPEVER RTU 4G GPRS Transmission Terminal Important Safety Instructions
- Read the instructions and warnings in the manual carefully before installation.
- the product should be situated away from the rain, exposure, dust, vibration, corrosion, and intense electromagnetic environment.
- Please avoid water and other liquids entering the product.
- Never use the product at sites where electrostatic could occur, and avoid the antenna close to a metal object.
- DO NOT disassemble or attempt to repair the product.
- Power supply: 9~48VDC can be customized according to customers’ requirements.
- Enable GPRS service for the SIM card before installation.
Overview
EPEVER RTU 4G A is a new wireless data transmission terminal based on the 4G
network. With the GSM/GPRS SIM card, the connected devices can easily access
the EPEVER cloud server to realize remote, wireless, and networked
communication. EPEVER RTU 4G A is suitable for EPEVER solar controller,
inverter, and inverter/charger.
Features:
- Extensive network coverage and flexible networking
- Low operating costs (charged by network flow)
- Adopt a non-standard DB9 male terminal
- Embedded in Modbus RTU protocol
- Automatic restore after disconnection
- Support RS485 communication
Appearance
The pin definition of the terminal(DB9 female) connected to the DB9 male terminal❸ is as follows.
Item | Terminal | Definition |
---|---|---|
1/2 | NC | Floating |
3 | VCC2 | Power2 (12V/200mA) |
4 | GND2 | Power GND2 |
5 | GND1 | Power GND1 |
6 | NC | Floating |
7 | RS485-A | RS485-A |
8 | RS485-B | RS485-B |
9 | VCC1 | Floating |
Indicators
You can observe the indicators’ color and status through the hole❷.
Name | Color | Status | Instruction |
---|
Network indicator (LED2)
|
Red
|
On solid
| Correct power supply
Not registered to the network
Slowly
flashing (5s)
| Successfully registered to the network
Sync. Indicator (LED1)|
Green
| Slowly
flashing (5s)
| Successfully registered to the network
---|---|---|---
Power indicator (LED2)|
Green
| Turn off after a flashing|
Correct power supply
Parameter Configuration
-
Step1: Connect the DB9 male connector ❸ to the PC through a DB9 to USB adap t er .
Note: Connect an external power adapter to the DB9 female terminal to supply the EPEVER RTU 4G A. -
Step2: Insert the SIM card and power on the EPEVER RTU 4G A. For detailed SIM card installation, refer to chapter 6, Installation.
-
Step3: Open the configuration tool on the PC and click the “connect” button to connect the EPEVER RTU 4G A successfully.
-
Step4: Click the “Read” and “Write” buttons to configure the parameter. Step5: After configuring, power on the product again to make the modified parameters take effect.
Common configuration parameters:
Parameters | Configuration |
---|---|
Server Info | No modifications are recommended |
APN
| Different countries have different APNs, and please make sure APN first. Products will not be connected to the Internet with fault APN.
China APN: CMNET
APN User| Enter it according to the actual
APN Key| Enter it according to the actual
Baud| Set it according to the connected controller or inverter
Note: The “APN” will be identified automatically. If it cannot be identified, the end-user can configure it by the above procedures.
Installation
Step1: Install the SIM Card
- Purchase a SIM card and activate the GPRS service.
- Undo the three screws from the EPEVER RTU 4G A.
- Push the shell upward and take out the circuit board.
- Take out the small SIM card and insert it into the card slot correctly.
- After installing successfully, reinstall the product shell.
Step2: Install the silicone pad
Tear off the silicone pad’s adhesive and stick the silicone pad to the DB9
terminal of the EPEVER RTU 4G A.
Step3: Install the antenna
Connect the 4G antenna to the antenna port of the EPEVER RTU 4G A.
Caution: As a wireless terminal, keep the antenna away from the human
body as far as possible during the operation process. Step4: Connect the
device
Take the connection with the solar controller as an example.
Connect the DB9 connector of the RS485 communication cable to the EPEVER RTU
4G A, then connect the ends of the RS485 communication cable to the master
LORA module and the battery separately.
Note: The EPEVER RTU 4G A supports 9~48V DC power. While a larger
transient current is needed when the wireless network sends the data, it is
suggested to adopt a DC power of 12V/500mA or above.
Note: If the EPEVER RTU 4G A is connected with the inverter or
inverter/charger. Connect the DB9 connector of the RS485 communication cable
to the EPEVER
RTU 4G A. Then connect the ends of the RS485 communication cable to the
battery and the device COM port. The master LORA module is no longer needed.
Specifications
Item | Specifications |
---|---|
Network type | GPRS class12 |
Coding method | CS1 – CS4(Comply with SMG31bis) |
Frequency
| GSM900/1800MHZ, CDMA: BC0, WCDMA: B1/B8, TD-SCDMA: B34/B39, LTE TDD: B38/B39/B40/B41,
LTE FDD: B1/B3/B5/B8
GPRS transmission rate| 150M
Network protocol| TCP/UDP/FTP/PPP/DNS
SIM card voltage| 3V/1.8V
Antenna connector| 50Ω IPX connector
Communication port| RS485
Serial port baud| 9600~115200bps
Power| 9~48VDC
Power consumption| Communication: <200mA/5V; Idle: <40mA/5V
Environment temperature| -40~85℃
Relative humidity| 0~95%(Non-condensing)
Dimension (L x W x H)| 101.2mm x 64mm x 26mm
Mounting hole size| ∅3.2mm
Net Weight| 54.0g
Electromagnetic compatibility| Electrostatic discharge immunity test, level 3
Anti-interference test, level 3
Connect the device to the EPEVER cloud server
The device connected with the EPEVER RTU 4G A can be added to the Cloud server
by the PC or mobile APP. Take adding the device through the mobile APP as an
example (For the operations of adding a device by PC, refer to the EPEVER
Cloud Server user manual).
CAUTION: Please get the Android or IOS version of the EPEVER cloud APP
according to your phone system and install it successfully.
- Step 1: Connect the EPEVER RTU 4G A with the device as chapter 5, Installation.
- Step 2: Open the APP, click the “EPEVER Cloud” icon, and input the account to log in.
- Step 3: Click the “Plant” icon (it is the “Light” icon instead when login in with the streetlight account), and select a project.
- Step 4: Click ” > Add Device” on the “Plant List” page.
- Step 5: Select the device to be added to the cloud server.
- Step 6: Select the connected module (the EPEVER RTU 4G A).
- Step 7: Input the ID (or scan the QR code) on the module label, and click “Confirm” to enter the Plant or Light project page directly.
Troubleshooting
Faults | Solutions |
---|
LED indicators are OFF
| 1. Check whether to supply power to the EPEVER RTU 4G A.
2. Check whether the power supply’s poles are connected inversely. The EPEVER RTU 4G A is equipped with anti-reverse protection. The reverse connection does not cause fatal damage. However, it affects the normal use before the correct connection is restored.
The network indicator is ON solid
| After power is on, the network indicator is on solid for 60 seconds. If it still cannot flash after 60 seconds, please check:
1. Check whether the SIM card is inserted correctly. 2. Check whether the GPRS service is activated. The Network indicator is on solid again after running for a while:
1. Check whether the server status is normal. 2. Check whether the SIM card is loose or arrear.
Smoke emits along with a pungent smell| The connected battery voltage exceeds the rated voltage, causing the internal components to burn out. Don’t hesitate to contact the supplier in time and send it to the manufacturer.
Unregister on the network
| 1. Check whether the SIM card is inserted correctly. 2. Check whether the SIM card has activated the GPRS service.
3. Check whether the input power is sufficient. Input power should be 12VDC/500mA.
Parameters can’t be configured| 1. Check whether the connection to the PC is correct. 2. Check whether the serial port selection is correct.
Read User Manual Online (PDF format)