GUDE WT-GP600 Garden pump domestic water supply unit
DELIVERED ITEMS
Starting-up the machine
Service connection
Engine protection
The pump must not in any case run without fillings.
Operation
Technical Data
Garden pump | The domestic water supply unit | |
---|---|---|
WT – GP 600 K | WT – GP 1000 I | **WT |
– HW 600 K** | WT – HW 1000 II | |
Art. No | 03015 | 03016 |
Service connection | 230 V~50Hz | 230 V~50Hz |
Rated input | 600 W | 1000 W |
Max. suction head | 7 m | 8 m |
Max. head of delivery | 35 m | 44 m |
Max. delivered quantity | 2800 l/h | 3500 l/h |
tank capacity | – | – |
Max. Water temperature | 35 °C | 35 °C |
Degree of protection | IPX4 | IPX4 |
Weight | 6,7 kg | 7,7 kg |
Read and understand the operating instructions before using the appliance. Familiarise yourself with the control elements and how to use the appliance properly. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties. The operator is responsible for accidents or risks to third parties. In case of any doubts about connection and operation refer please to our customer center
This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Specified Conditions Of Use
The pump is designed for pumping clean water only to supply the home with water and to use it at home, in the garden, courtyard, and for fields. Respecting technical data and safety precautions. Do not use this product in any other way as stated for normal use. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages. Do not use the pump at outside temperatures over 40 °C or under 0 °C.
- The pump is not suited for long-run operation (e.g. as a circulation pump in ponds or streams). When used in this manner, its service life is curtailed correspondingly. In these cases, then, use a time switch to secure sufficient idle periods between cycles of operation.
- Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
- Do not use the pump for drinking water!
- The pump must not be connected to the existing water-supply network as a pressure-boosting device.
- Never use the pump as a pool circulation pump.
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. If you seek help, state the following pieces of information: 1. Accident site, 2. Accident type, 3. A number of injured persons, 4. Injury type(s).
Symbols
- WARNING/CAUTION!
- WARNING – Read the operating instructions to reduce the risk of injury.
- Unplug the machine before any work on it.
- Cable pulling/transport prohibited
- Staying in the transportation medium prohibited
- Warning against dangerous electric voltage
- Any damaged or disposed of electric or electronic devices must be delivered to appropriate collection centers.
- CE marking
Safety Instructions
Do not grab the feeder cable, plunge the pump, or lift or carry it while it is connected to the grid. Unplug the device prior to submersion, upon the termination of operation, in the course of defect removal, and prior to performing maintenance procedures. If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.). The temperature of the drained liquid must not exceed +35 °C. The pump must not in any case run without fillings.
Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it. If the pump is used in ponds, wells, etc., and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed. The user is responsible to third parties if the pump (dum-ping stations, etc.) is used. Check the cable and/or socket for damages before the appliance putting into operation. Do not expose the appliance to rain and do not use it in wet or moisture conditions. Avoid installing the appliance in wet shafts (risk of short circuit, corrosion effects)! When using the pump for domestic water supply, always observe the local regulations of water management authorities and the wastewater drainage. In cold weather, the pumping body motor should not be wrapped in a blanket or another piece of textile with the intent to prevent the water from freezing.
Mains Connection
- Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA).
- WARNING! Electric shock! There is a risk of injury caused by electric shock.
Before putting it into operation, a qualified electrician must check whether the electric safety measures required are in place. Any national regulations in this regard must be complied with. Electric connection to a socket. Check the voltage. Technical data given on the type label must correspond with electric network voltage. It is necessary to make sure the connecting socket was not near water and humidity and the plug was protected against humidity. Only use splash-proof extension cables approved for outdoor purposes. Protect the feeder cable from excessive temperatures, oil, and sharp edges.
Cleaning/Maintenance
Unplug the machine before any work on it
Before using the appliance, perform a visual inspection at all times to
make sure the power cord and the plug, in particular, are not damaged on the
charger. The appliance must not be used if damaged or safety equipment is
defective. Replace any worn-out and damaged parts. Caution! If the power cord
of the appliance gets damaged, it must be replaced by the manufacturer or its
customer service or a similarly qualified person to avoid danger. Repairs and
works specified in these Instructions may only be performed by qualified
authorized staff. Use only original accessories and original spare parts. Only
a regularly maintained and treated appliance can serve as a satisfactory aid.
Insufficient maintenance and care can lead to unforeseen accidents and
injuries. To ensure the long service life of the pump seal we recommend
rinsing the pump with clean water at regular intervals. During winter storing,
it is necessary to make sure there is no water in the appliance as the frost
could damage the appliance. Prior to transportation, it is necessary to unplug
the pump from the grid! The device has to be completely emptied and stored
with frost-proof protection. Adhesion of mechanical seals can be prevented if
you rinse the pump with appropriate oil (for example, vegetable oil). If
necessary, a list of spare parts can be found at
www.guede.com.
Guarantee
The warranty period of 12 months applies to commercial use and 24 months applies to private use and commences on the day of purchase of the device. The guarantee solely covers inadequacies caused by material defects or manufacturing defects. Original payment voucher with the date of the sale needs to be submitted for any claim in the guarantee period. The guarantee does not cover any unauthorized use such as appliance overloading, use of violence, and damage as a result of any unauthorized interference or caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee. The device has to be checked on a regular basis to ensure perfect functioning.
Let us refer to the fact we do not assume any respon-sibility – according to standards in force – for damage eventually caused by our appliances in the below-mentioned cases: Unprofessional repairs executed by unauthorised service centres;
- Use in conflict with the designed purpose, or failure to observe the use as designed.
- Pump overload with a continuous run.
- Damage as a result of icing or any other fault caused by climatic influences.
Identical regulations apply for accessory parts. To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the ow-ner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).
Important information for the customer
Please be sure to know that returning the product in or after the warranty
period must be made in the original packaging.
Service
Do you have any technical questions? Do you have a complaint? Do you require spare parts or an opera-ting manual? You can get quick and unbureaucratic assistance in the Service section on the homepage of our service partner Güde GmbH & Co. KG (www.guede.com). Please help us to help you. In order to be able to identify your device in the case of a complaint, our service partner will require its serial number, article number, and year of manufacture. All this information can be found on the nameplate.
- Tel.: + 49 (0) 79 04 / 700-360
- Fax: + 49 (0) 79 04 / 700-51999
- E-Mail: support@ts.guede.com.
Inspection and maintenance plan
Time interval | Description | Any other details |
---|---|---|
As needed | Clean the check valve and the prefilter. | Check the check valve |
function.
Failure removal
Failures | Causes | Removal |
---|---|---|
Engine does not start | No power supply. Blocked pump wheel | Turn the engine |
shaft with screwdri- ver through the fan cover (to release
friction circles sealing that may be stuck together).
Pump does not suck| Missing, loose or blocked check valve Check valve is not in water.
No water in the pump shell. Too high suction head.
Air bubbles in the suction pipeline. Connections not sealed, pump sucks air, pump is not deaerated.
Prefilter clogged
| Fix or clean the check valve. Immerse the check valve into water. Fill the pump shell with water.
Check the suction head.
Check the tighten of suction pipeline. Clean the prefilter.
Thermal detector swit- ching the pump off| Pump is overheated and switched off by the thermal overloading protection.
No electric power supply.
Impurity particles (e.g. pebbles) have settled down in the suction hole.
| Let the device getting cool!
Check power supply.
Disassemble and clean the suction hose, prevent from suction of foreign substances.
Insufficient amount of water pumped| Too high suction head.
Strainer of the check valve dirty Water level quickly drops down
| Check the suction head.
Clean the strainer., Position the check valve lower.
Clean the prefilter.
Clean the pump and replace worn parts. (qualified workshop)
Reduced switching intervals| Air pressure in the receiver too low| Control air pressure.