HYUNDAI WS 2215 Digital Thermometer with Humidity Instruction Manual
- June 5, 2024
- HYUNDAI
Table of Contents
HYUNDAI WS 2215 Digital Thermometer with Humidity
FEATURES
- Indoor & Outdoor Temperature
- Indoor & Outdoor Humidity
- Past 24 Hours Max/Min. Record
- Comfort Icons (according to both temp. & humidity)
- Indoor & Outdoor Temperature and Humidity Alert
MAIN UNIT APPEARANCE
Part A – LCD
- A1: Indoor/Outdoor Temperature
- A2: Past 24 hrs Minimum Temperature Record
- A3: Past 24 hrs Minimum Temperature Record
- A4: Indoor/Outdoor Humidity
- A5: Past 24 hrs Minimum Humidity Record
- A6: Past 24 hrs Minimum Humidity Record
Part B – Buttons
- B1: “IN/OUT/SEARCH” button
- B2: “▲” button
- B3: “RESET” button
- B4: “▼/C/F” button
- B5: “ALERT” button
Part C – Structure
- C1: Wall Mount Hole
- C2: Stand
- C3: Battery Cover
OUTDOOR THERMO SENSOR
- D1: Transmission Indication LED
- D2: Outdoor Temperature display
- D3: Outdoor Humidity display
- D4: Battery Compartment
- D5: Wall Mount Hole
- D6: “RESET” button
- D7: “C/F” button
- D8: Temperature Probe Plug & Jack
- D9: Stand
GETTING STARTED
Main Unit:
- Slide open the main unit battery compartment cover [C3]
- Insert 2 x AAA batteries observing polarity [“+” and “–” marks]
- Replace main unit battery compartment cover [C3]
- Use a pin to press the RESET [B3] button on the rear of the main unit, the main unit is now ready for use.
Outdoor Thermo Sensor
- The batteries compartment (D4) of thermo sensor is located behind the back cover, unscrews the batteries cover to open.
- Insert 2 x AAA batteries observing polarity [“+” and “–” marks]
INSTALLATION
Main Unit
The main unit can be placed onto any flat surface (C2), or wall mounted by the
hanging hole (C1) at the back of the unit.
Outdoor Sensor
The remote sensor should be securely mounted onto a horizontal surface.
Note: Transmissions between receiver and transmitter can reach up to 30 m
in open area. Open Area: there are no interfering obstacles such as buildings,
trees, vehicles, high voltage lines, etc.
TEMPERATURE & HUMIDITY
Rf Transmission Procedure:
- The outdoor sensor will automatically transmit temperature and humidity signal to the main unit after the batteries are inserted.
- If main unit failed to receive a transmission from the outdoor thermal sensor in first 3 minutes after the batteries are inserted (“- – . –” display on the LCD), hold the “SEARCH” button (B1) for 3 seconds to receive transmission manually. RF icon flashes on the LCD.
Temperature & Humidity
-
After start-up, the unit would display indoor Temperature, Indoor humidity and Past 24 Hours Indoor Maximum and Minimum Temperature and Humidity Record.
-
Press “IN/OUT” button (B1) to view the outdoor Channel’s data, including outdoor temperature, outdoor humidity and past 24 Hours outdoor Max. & Min Temperature and Humidity Record. Press “IN/OUT” button (B1) select to view indoor/outdoor Channel’s data, the sequence is shown as follow:
PRESS “IN/OUT” button -
Hold “SEARCH” button (B1) for 3 seconds to clear the record on outdoor channel manually, and receive the transmission from outdoor automatically again.
Celsius / fahrenheit
- Press “°C/°F” button (B4) to select Indoor/Outdoor Temperature in Celsius mode or Fahrenheit mode.
- If the temperature is out of the measurable range, LL.L (beyond the minimum temperature) or HH.H (beyond the maximum temperature) will be shown on the LCD.
Comfort Indicator Icon
There are four different icons would be display according to the temperature and humidity condition:
Temperature & Humidity Alert function
- When viewing indoor or outdoor channel, press “ALERT” button to select to activate the alert function for this channel. Once ALERT function is activated, the icon “ ” appears on the LCD. When viewing Indoor Channel, press ALERT button select to:
- Activate Indoor Temperature Alert function
- Activate Indoor Humidity Alert function
- Activate Indoor temp. & Humidity Alert function
- Deactivate Alert function for Indoor Temp&Humidity
- Hold “ALERT” button for 3 seconds to enter Temperature & Humidity Alert setting. Icon “ ” beside Temperature’s digits flash. Press “▲” or “▼” button to select alert setting for Indoor or Outdoor Temperature & Humidity, Press “ALERT” button to confirm the setting.
- Setting Sequence as follow: Upper limit of temperature, Lower limit of Temperature, Upper limit of Humidity, Lower limit of Humidity.
- Press “▲” (B2) or “▼” (B4) button to set the upper “ ” and lower “ ” limit of the temperature. Press “ALERT“ button (B5) to confirm the setting, and move to the Humidity alert setting. Press “▲” (B2) or “▼“ (B4) button to set the upper “ ” and lower “ ” limit of the Humidity, press “ALERT” button to confirm and quit the setting.
- When it’s alert, the corresponding icon “ ” or “ ” would flash on the LCD. Press any buttons to stop the alert sound, otherwise, it will sound for 2 minutes, and stop automatically.
Note: The Setting Mode will automatically exit in 15 seconds without any adjustment.
frost Alert
“ ” is shown if the outdoor temperature (any channel) is between -2 °C ~ +3
°C.
LOW BATTERY
The low battery icon “ ” will appear at particular channel indicating that thermo sensor unit of the channel is in low battery status. The batteries should be replaced.
PRECAUTIONS
- Use a pin to press the reset button (B3) if the unit does not work properly.
- Avoid placing the clock near interference sources/metal frames such as computer or TV sets.
- Do not expose it to direct sunlight, heavy heat, cold, high humidity or wet areas.
- The outdoor sensor must not be set up and installed under water. Set it up in away direct sunlight and Rain.
- Never clean the device using abrasive or corrosive materials or products. Abrasive cleaning agents may scratch plastic parts and corrode electronic circuits.
SPECIfICATIONS
Indoor Data:|
---|---
Temperature range:| -9.9 to 50 °C [+14.2 to +122 °F]
Temperature Units Measured:| °C or °F [switch able]
Humidity Range:| 20 % to 95 %
Outdoor Data:|
Transmission distance: (open area)| 30 m @ 433 MHz
Temperature range:| -20 ~ 50 °C [-4 ~ +122 °F]
Humidity Range:| 20 % to 99 %
Mount:| wall / table
Main Unit Dimensions:| W 136 x H 82 x D 17 mm
Thermo Sensor Dimensions:| W 62 x H 101 x D 24 mm
Main Unit weight (NET):| 102 g
Thermo Sensor weight (NET):| 66 g
Battery Requirements:|
Base Station [indoor]:| 2 x AAA batteries
Sensors [outdoor]:| 2 x AAA batteries
WE RESERVE THE RIGHT TO CHANGE TECHNICAL SPECIfICATIONS.
WARNING: Do not use this product near water, in wet areas to avoid fire
or injury of electric current. Always turn off the product when you don’t use
it or before
a revision. There aren’t any parts in this appliance which are reparable by
consumer. Always appeal to a qualified authorized service. The product is
under a dangerous tension.
Old electrical appliances, used batteries and accumulators disposal
This symbol appearing on the product, on the product accessories or on the product packing means that the product must not be disposed as household waste. When the product/ battery durability is over, please, deliver the product or battery (if it is enclosed) to the respective collection point, where the electrical appliances or batteries will be recycled. The places, where the used electrical appliances are collected, exist in the European Union and in other European countries as well. By proper disposal of the product you can prevent possible negative impact on environment and human health, which might otherwise occur as a consequence of improper manipulation with the product or battery/ accumulator. Recycling of materials contributes to protection of natural resources. Therefore, please, do not throw the old electrical appliances and batteries/ accumulators in the household waste. Information, where it is possible to leave the old electrical appliances for free, is provided at your local authority, at the store where you have bought the product. Information, where you can leave the batteries and accumulators for free, is provided to you at the store, at your local authority.
CE DECLARATION Of CONfORMITy
The manufacturer (authorised representative):
HP TRONIC Zlín, spol. s r.o., Prštné Kútiky 637, 760 01 Zlín,
Company Identification No.: 499 73 053,
hereby declares that the hereinafter described product:
Digital thermometer and hygrometer with wireless data transmission:
Hyundai wS 2215,
Purpose of use: signal transmission from the transmitting device to the
receiving device in the Czech Republic and in the EU member states, used
frequency: 433,92 MHz band
is in conformance with the provisions of the GD No. 426/2000 Coll. that is in
conformity with the R&TTE Directive 1999/5/EC concerning radio and
telecommunication devices.
The following technical regulations have been applied in assessing the
conformance: Harmonised standards:
ETSI EN 300 220-1 V2.3.1 (2010-02)
ETSI EN 300 220-2 V2.3.1 (2010-02)
ETSI EN 301 489-3 V1.4.1 (2002-08)
ETSI EN 301 489-1 V1.9.2 (2011-09)
ETSI EN 300 220-1 V2.1.1 (2006-04)
ETSI EN 300 220-2 V2.1.2 (2007-06)
EN 60950-1:2006+A11:2009+A1:2010+A12:2011
The test results are provided in Test Reports No. GTSE12070076101,
GTSE12070076102, GTSS12070034801, GTSE11020009901, GTSE11020009902 and
GTSS11020006201 issued by the GTS – Global United Technology Services Co.,
Ltd., China.
The conformity has been assessed according to the Annex No. 3 to GD No.
426/2000 Coll.
We declare that the product complies with the basic requirements of the above-
mentioned GD, i.e. the user safety and health protection, electromagnetic
compatibility and effective utilisation of the spectrum.
Declaration issuance date and venue: 19.7.2012, Zlín
Authorized person’s stamp:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>