WOHLER RM 400 Drain Cleaning Machine Instruction Manual
- June 5, 2024
- WOHLER
Table of Contents
Operating manual
Drain Cleaning Machine
Best.-Nr. 24864 – 2022-05-20
General information
1.1 Operation Manual information
This operation manual allows you to safely work with the Wöhler RM 400 Drain Cleaning Machine. Please keep this manual for your information. The Wöhler RM 400 should be used by trained professionals for its intended use only. Liability is void for any damages caused by not following this manual.
1.2 Notes
WARNING!
Not following this warning can cause injury or death.
**ATTENTION!**
Not following this note can cause permanent damage to the device.
1.3 Intended Use
NOTE!
Useful information.
The Wöhler RM 400 drain cleaning machine is suitable for cleaning pipelines Ø
50 to 110 mm.
1.4 Scope of delivery
Wöhler RM 400 | Set |
---|---|
Wöhler RM 400 Drain Cleaning Machine | Wöhler RM 400 |
1 carrying case for drain cleaning accessories | |
1 Straight auger Ø 22 mm |
– blockages caused by textiles, paper, cellulose, kitchen waste
| 1 Bulb auger Ø 22 mm
– narrow pipe bends
– minor textile and cellulose blockages
| 1 Spade cutter Ø 22 mm
– silty pipes
– drains from the washing
machines, dishwashers
| 1 C-Cutter Ø 22 mm
– mudding
– viscous grease residues
---|---
| 1 coupling key 5 mm
| 1 pair of drain cleaning protection cloves
1.5 Transportation and stocking
ATTENTION!
Improper transport can harm the instrument.
- Always secure the unit with straps.
1.6 Information on disposal
Electronic equipment does not belong in domestic waste, but must be disposed of in accordance with the applicable statutory provisions.
1.7 Manufacturer
Wöhler Technik GmbH
Wöhler-Platz 1, 33181 Bad Wünnenberg
E-Mail: info@woehler.de
1.8 Important information
**WARNING!
Protective equipment:
Guide the cable only with a suitable guide glove.
Wear protective glasses depending on the application.
Wear safety shoes with rubber soles (insulation) during cleaning work.
ATTENTION!
Work area:
Place the drain cleaning machine on a straight and non-slip surface.
Never place the main cable in the area of the pipe cleaning cable.
Always work with the guide hose.
WARNING!**
Before switching the drain cleaner on.
Avoid unintentional rotation of the cable. Put the control switch in OFF-
Position before connecting the drain cleaner to the power supply.
The danger of jamming: Do not form a large working arc with the cable. The
cable can overturn.
Make sure that the distance between the Wöhler RM 400 and the pipe entrance is
max. 50cm. Do not pull out the cable anymore. Risk of injury: The cable can
jump out of the tube under tension.
NOTE!
Select the appropriate auger for the blockage and the pipe diameter in order
to prevent the auger from hooking and thus the cable from being thrown out of
the pipe. Use a
camera system to identify the cause of the blockage and select the appropriate
tool.
NOTE!
Mechanical pipe cleaning should always be carried out from above, towards the
blockage.
**WARNING!**
Maintenance:
Disconnect the electric power before making any adjustment, accessory
assembly, and maintenance. Keep the electric part of the machine from getting
wet. Do not immerse
the appliance in water when cleaning it.
Specifications
Operation|
---|---
Area|
Outdoor and indoor pipeline|
Tube Diameter| 50 to 110 mm
Max. operating length| 23 m
|
Cable|
0 / Length| 12,7 mm / 23 m
Coupling type| Snap Lock 0 22 mm
|
Technical Data RM 400|
Input Power| 390 W
Rated Voltage / Rated Frequency
Rotate speed| 220 V
50 Hz
300 rotations per minute
Automatic feed speed| 5 m/min
Protection Class| IP 44
Weight| 41,78 kg
Components
-
ON-/OFF-Switch / FOR / REV:
• Switch on / off
• Rotation direction of cable -
Handle
-
Foot pedal
-
Cable drum l
-
Cable
-
Outlet
-
Black lock knob to fix the cable
Loosen the lock knob to pull out or push in the cable by hand Fix the lock knob hand-tight for automatic feed
3.1 Control switch
Off: Stop
For: Forward rotation, unblocking
Rev: Reverse rotation, retrieve jammed cable
WARNING!
Before connecting the device to the electric power supply check switch first
for position off.
Initial operation
-
First, mount the axle with the wheels.
NOTE!
The wheel side with the stronger bulge points inwards. -
Then attach the handle with the 4 nuts included in the scope of delivery.
Operation
5.1 Preparation
-
Make sure that the control switch is set to OFF.
-
Select an appropriate auger and securely connect it to the cable with the snap-lock.
-
To release the snap-lock after cleaning, insert the coupling key into the hole. The coupling ey is included in the scope of delivery.
-
Then pull the snap-lock apart with two hands.
5.2 PRCD-Switch
The Wöhler RM 400 has a PRCD switch (personal safety switch) to protect users and drain cleaner against dangerous currents due to possibly defective electrical equipment.
**WARNING!**
Check the functionality of the switch before each use of the RM 400 as
follows:
-
Turn on the Wöhler RM 400.
-
Press TEST.
If the device switches off automatically, the PRCD switch is working and it is safe to work with the Wöhler RM 400. -
If the Wöhler RM 400 is still working after pressing the “TEST button”, disconnect the power supply immediately.
-
To start normal working mode after inspection, press RÜCKSETZEN (Reset).
5.3 Drain Cleaning
WARNING!
Protective equipment:
Guide the cable only with a suitable protective glove.
Wear protective glasses depending on the application. Wear safety shoes with
rubber soles (insulation) during cleaning work.
- Loosen the black lock knob.
- Select an appropriate auger and securely connect it to the cable.
- Position the machine close in front of the opening of the pipeline you wish to clean. Ensure a firm stand.
- Push the cable through the outlet nozzle into the drain entrance.
- Then tighten the lock knob a little so that the cable can be operated freely..
NOTE!
If the lock knob is tightened too much, the cable will block the machine. If
it is tightened too little, no back and forth movement is possible.
- Connect the Wöhler RM 400 to the mains and perform the test with the PRCD switch according to chapter 6.1.1.
- The automatic feed can be adjusted via the control switch and handle.
ATTENTION!
Never pull or push the cable while the auto-feed is active.
Setting options / settings
-
Proceed as follows:
-
Switch FOR + handle up
Cable turns to the right and is pushed out. -
Switch FOR + handle down
Cable turns to the right and is retracted. -
Switch REV + handle up
Cable turns to the left and is pushed out. -
Switch REV + handle down
Cable turns to the left and is retracted. -
Handle center / neutral
Cable rotating, no forward or reverse feed.
Start RM 400
**WARNING!**
Do not form a large working arc with the cable. The cable can jump under
tension – the risk of injury!
- Press the foot pedal to start automatic feed or automatic reverse feed.
- When the cable has moved into the pipe so far that the working bend is relieved, pull the cable out of the machine and form a networking bend.
Important information
ATTENTION!
Never insert the cable with pressure.
- If there is a slight resistance, center the handle and let the tool work. If necessary, use a Cutter drill to loosen blockages.
- If you feel the cable blocking when inserting, immediately set the feed handle to “reverse” and let the cable run reverse for approx. 20 – 30 cm.
Troubleshooting
WARNING!
If the above instructions are not followed, the cable may twist in the cable
drum. In this case switch off the machine.
- Remove the cable out of the pipeline.
- Loosen the lock knob, set the handle to the middle position, and carefully pull out the cable of the drum by hand until the part remaining in the cable drum is no longer twisted. (If necessary, pull out the cable completely).
- If the drain cleaning cable is not pulled out completely, turn the drum by hand and push the cable back in carefully. If necessary, pull out a part of the cable several times and push it back in.
- Once the cable is completely pulled out, carefully pull it with the RM 400 switched on: Pull the handle down and press the foot pedal.
5.4 After drain cleaning
- Pull the cable out of the pipeline and clean it with water.
- Flush and dry the drain cleaning cable and augers. Lubricate them with oil and keep them in a dry place to prevent rusting.
Maintenance
6.1 Regular maintenance
WARNING!
Switch off the machine and disconnect the electric power before making any
adjustment, accessory assembly, or maintenance.
NOTE!
The bearings of the Wöhler RM 400 are self-lubricating and therefore do not
need to be greased.
- Take care that no electric part of the machine gets wet.
6.2 Exchange of automatic feed unit
Prior to the next use, after being stored for a long time, check the machine for free rotation, then turn on the control switch. If the machine shaft does not rotate after the motor is running or the handle is pressed, there may be rust inside. Turn off the electric power immediately to avoid electric damage. In this case, send it to the service or replace the automatic feed unit.
Declaration of Conformity
The product:
Wöhler RM 400 Drain Cleaning Machine
has been tested in accordance with essential protection requirements of the
Council Directive 2014/30/EU and found the test results indeed meet the
limitation of the relevant test standards listed below:
EN 55014:-1:2017
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 55014-2:2015
Guaranty and Service
8.1 Guaranty
Each Wohler RM 400 Drain Cleaning Machine will be tested in all functions and
will leave our factory only after extensive quality control testing. The final
control will be recorded in detail in a test report and delivered with any
unit.
If used properly, the warranty period for the Wöhler RM 400 will be 12 months
from the date of sale. Consumables such as drain cleaning cables, augers and
drain cleaning protection gloves are excluded. This warranty does not cover
the freight and packing costs when the device is sent to the factory for
repair. Service by non-authorized personnel or making modifications to the
device voids any warranty.
8.2 Service
Excellent SERVICE is very important to us. Therefore, of course, we are readily available to assist you after the warranty period ends.
- When you send your meter to us, we will repair it within a few days and return it via our trusted parcel carrier.
- Immediate help is provided by our technical staff over the telephone.
Best.-Nr. 24864 – 2022-05-20
Documents / Resources
|
WOHLER RM 400 Drain Cleaning
Machine
[pdf] Instruction Manual
RM 400, Drain Cleaning Machine, Cleaning Machine, RM 400, Machine
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>