ViandPRO VP-CH93BLK Aria Ceiling Hood User Manual
- June 4, 2024
- ViandPRO
Table of Contents
Aria Ceiling Hood
Installation And User’s Manual
VP-CH93WHTSS VP-CH93BLKSS
VP-CH93WHT VP-CH93BLK
Dear Customer,
Congratulations on purchasing this equipment. Please read this manual
carefully and take care of the following hints to avoid damage. Any failure
caused by ignoring the items and cautions mentioned in the instruction manual
is not covered by our warranty and any liability.
Declaration of conformity
**** This product is conform to the following
European Directives:
2014/30/EU (EMC)
2014/35/EU (LVD)
2011/65/EU (RoHS)
2009/125/EC (ErP)
Safety instructions
- Thank you for purchasing this cooker hood. Please read the instruction manual carefully before you use the cooker hood, and keep it in a safe place.
- The installation work must be carried out by a qualified electrician or competent person. Before you use the cooker hood, make sure that the voltage (V) and the frequency (Hz) indicated on the cooker hood are exactly the same as the voltage (V) and the frequency (Hz) in your home.
- The manufacturer and the agent will not bear any responsibility for the damage caused by inappropriate installation and usage.
- Never let children operate the cooker hood.
- The cooker hood is for home use only. It is not suitable for barbecues, Roast shops, and commercial purposes.
- The cooker hood and its filter mesh should be cleaned regularly in order to keep it in good working order.
- Before cleaning, switch the power off at the main supply.
- Clean the cooker hood according to the instruction manual and keep the cooker hood from the danger of burning.
- Prohibit putting the cooker hood by fire.
- If there is any fault with the appliance, please call the service department to request a service engineer.
- This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- The instructions shall state the substance of the following: there shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).
- Do not flambé under the range hood. Accessible parts may become hot when used with cooking appliances.
Important Hints on Installation
- The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).
- Regulations concerning the discharge of air have to be fulfilled.
Important notes about the extraction mode
WARNING
Risk of poisoning from exhaust gases sucked back. Never operate the device
in extraction mode simultaneously with an open flue appliance when there is
not adequate airflow guaranteed.
Open flue combustion equipment (for example, gas, oil, wood, or coal-fired
heaters, tankless water heaters, water heaters) pulls combustion air from the
room and runs it through an exhaust pipe or chimney to the outside. In the
extraction mode, indoor air is removed from the kitchen and the adjacent rooms
– without sufficient air intake, this creates a vacuum. Toxic gases from the
chimney or extraction flue can thereby be sucked back into the living spaces.
- Always ensure that a sufficient supply of fresh air is guaranteed and that the air can circulate.
- An air supply/extractor box alone does not ensure compliance with the limit value.
Safe operation is only possible when the negative pressure in the room where
the appliance is located does not exceed 4 Pa (0.04 bar). This can be achieved
when the air required for combustion can flow through openings that are not
closable, For example in doors, windows, in conjunction with an air supply/
extractor box, or through other technical measures. In any case, consult a
qualified chimney sweep who can assess the entire ventilation of your house
and propose appropriate measures for adequate ventilation.
If the hood is used exclusively in the recirculation mode, the unrestricted
operation is possible.
WARNING
Fire hazard from flying sparks. Only install equipment on a fireplace for
solid fuels (for example, wood or coal), if a closed, non-removable cover is
available.
Installation
Preparation
If you have an outlet to the outside, your cooker hood can be connected as
below picture by means of an extraction duct (enamel, aluminum, flexible pipe
or inflammable material with an interior diameter of 150 mm)
- Before installation, tum the unit off and unplug it from the outlet.
- The cooker hood should be placed at a distance of 65- 150cm above the cooking plane for the best effect.
Installation (Vent outside)
Note: ‘When the range hood and appliance supplied with energy other
than electricity are simultaneously in operation, the negative pressure in the
room must not exceed 4 Pa (4 x 10· 5 Bar).
Dimensions
Ceiling Installation
|
---|---
Saw a hole in the ceiling according to the dimensions of the extractor hood.|
Slide the extractor hood into the opening.
Push the extractor hood upwards until the brackets engage in the false
ceiling. If you do not engage, use a screwdriver to pierce the four holes in
the lower corners of the hood.
The brackets should be adjusted so that the lower edge of the extractor hood
is flush with the ceiling. Screw 4 screws through the four holes in the lower
corners of the hood.
Note: The ventilation pipe must be installed after adjusting the
extractor hood.
When mounting a non-return valve, it must be ensured that the valve can be
opened freely. If the valve cannot be opened freely, it can reduce the suction
power and increase the noise from the extractor hood.
If the extractor hood is used for recirculation and there is no external
ventilation (exhaust air), it is important that the ventilation is not blocked
or impaired, as this can damage the extractor hood, reduce capacity and
increase noise. In addition, no non-return valve can be installed in
recirculation mode.
Operation
Control Panel and Button Functions
**** | Switch the engine on and off. |
---|---|
1 | The motor runs at low speed. |
2 | The motor runs at medium speed. |
3 | The motor runs at high speed. |
Switch the light on and off. |
Setting the Lighting Colour
In standby mode, press and hold the LIGHT button to adjust the illumination
color. Use the button
(3) to adjust one of the following light colors. The lights will show the
corresponding number (L1- L9):
Display | Colour | Display | Colour |
---|---|---|---|
L1 | White | L6 | Purple |
L2 | Red | L7 | Orange |
L3 | Green | L8 | Cyan |
L4 | Blue | L9 | Yellow-green |
L5 | Yellow |
Remote Control
| |
Press button 11) to switch the motor on or off.
---|---|---
2| Press button (2) to decrease power or speed.
3| Press button (3) to increase power or speed.
4| Press button (4) to turn the light on or off. if only the light is on and
5| Press the key (5) while the power is on to activate the off timer. if the
timer
indicator in the display Rashes, the timer is active. The preset time for the
timer is 5 minutes. When the timer has expired, the cooker hood will
automatically turn off.
To calibrate the remote control
While in standby mode, long press the on/off button on the hood panel for 3
seconds till it flashes, then immediately press the on/off button on the
remote control to complete
- If the calibration was successful, an acoustic signal sounds.
- If the calibration was not successful, the cooker hood switches to standby mode.
TECHNICAL DATA
Type| Ceiling Cooker hood
Material| Stainless steel + Glass
Installation-width in cm•| 90.00
Ceiling installation.| ✓
Control Type| Touch 4- Remote
Recirculation| Optional
Annual energy consumption| 51.4 kW/h
(AEChood) Energy efficiency category| D
Fluid dynamical efficiency (FDEhood)| 10.
4. Fluid dynamical efficiency category| E
Lighting efficiency (LEhood)| 4.0 lux/W
Lighting efficiency category| G
Grease separation| 69.%
Grease separation category| D
Airflow “| 317.2 m3/11 411.1 m3/h
Maximum airflow Qmax| 411.1 m3/11
flow at boost setting, Air| N/A
A-rated noise emission *| 54 dB 59 dB
Power consumption off (Po)| 0.40 W
Power consumption standby (Ps) Power| 0.38W
consumption lighting system (WI)| 10.0 W
Connected load| 85W
.Illuminant t| ✓/ LED
Power consumption per illuminant unit| 25 W
Voltage / frequency| 220 – 240 V AC / 50Hz
Height adjustment in cm| 20
Grease filter/material/dishwasher-| 2 aluminum ✓
proof Carbon filter “*| optional
Installation material| ✓
.Instruction manual| ✓
Dimensions appliance WW1) in cm| 20432.00.’90.00
Weight net / gross in kg| 15.30 / 17.90
Troubleshooting
Fault | Cause | Solution |
---|---|---|
Light on, but the fan does not work | The fan blade is jammed. | Switch of the |
unit and Repair by qualified service
personnel only.
The motor is damaged.
Both light and fan do not work| The light bulb burned out.| Replace the bulb
with the correct rating.
Power cord lose| Plugin to the power supply again.
Serious vibration of the unit| The fan blade is damaged.| Switch of the unit
and Repair by qualified service personnel only.
The fan motor is not fixed
tightly.
The unit is not hung properly on the bracket.| Takedown the unit and check
whether the bracket is in the proper location.
Suction performance is not good| The too long distance between the unit and
the cooking plane| Readjust the distance to 65 – 150cm
Cleaning and Care
Monthly Cleaning for Grease Filter
Clean the filter every month can prevent any risk of fire. The filter collects
grease, smoke, and dust, so the filter is directly affecting the efficiency of
the cooker hood. If not cleaned, the grease residue (potential flammable) will
saturate on the filter. Clean it with household cleaning detergent.
Replacing Bulbs
- Switch the unit off and unplug the appliance.
- Remove the lamp cover by unscrewing the 2 screws.
- Unscrew the incandescent bulb. Replace with the same type and rated bulb.
HINTS ON DISPOSAL
According to the European waste regulation, 2012/19/EU this symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead, it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling this product, please contact your local council or your household waste disposal service.
Aria Ceiling Hood Fitting Instructions and Operation
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>