Dear Customer,
Congratulations on purchasing this equipment. Please read this manual
carefully and take care of the following hints to avoid damages. Any failure
caused by ignoring the items and cautions mentioned in the instruction manual
is not covered by our warranty and any liability.
SAFETY INSTRUCTIONS
- Thank you for purchasing this cooker hood. Please read the instruction manual carefully before you use the cooker hood, and keep it in a safe place.
- The installation work must be carried out by a qualified electrician or competent person. Before you use the cooker hood, make sure that the voltage (V) and the frequency (Hz) indicated on the cooker hood are exactly the same as the voltage (V) and the frequency (Hz) in your home.
- The manufacturer and the agent will not bear any responsibility for the damage caused by inappropriate installation and usage.
- Never let children operate the cooker hood.
- The cooker hood is for home use only. It is not suitable for barbecues, Roast shop and commercial purposes.
- The cooker hood and its filter mesh should be cleaned regularly in order to keep it in good working order.
- Before cleaning, switch the power off at the main supply.
- Clean the cooker hood according to the instruction manual and keep the cooker hood from the danger of burning.
- Prohibit putting the cooker hood by fire.
- If there is any fault with the appliance, please call the service department to request a service engineer.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- The instructions shall state the substance of the following: there shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).
- Do not flambé under the range hood. Accessible parts may become hot when used with cooking appliances.
Important Hints on Installation
- The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).
- Regulations concerning the discharge of air have to be fulfilled.
WARNING
Risk of poisoning from exhaust gases sucked back. Never operate the device in
extraction mode simultaneously with an open flue appliance when there is not
adequate airflow guaranteed. Open flue combustion equipment (for example, gas,
oil, wood or coal-fired heaters, tankless water heaters, water heaters) pulls
combustion air from the room and runs it through an exhaust pipe or chimney to
the outside. In the extraction mode, indoor air is removed from the kitchen
and the adjacent rooms – without sufficient air intake, this creates a vacuum.
Toxic gases from the chimney or extraction flue can thereby be sucked back
into the living spaces.
- Always ensure that a sufficient supply of fresh air is guaranteed and that the air can circulate.
- An air supply/extractor box alone does not ensure compliance with the limit value.
Safe operation is only possible when the negative pressure in the room where the appliance is located does not exceed 4 Pa (0.04 bar). This can be achieved when the air required for combustion can flow through openings that are not closable, for example in doors, windows, in conjunction with an air supply/ extractor box or through other technical measures. In any case, consult a qualified chimney sweep who can assess the entire ventilation of your house and propose appropriate measures for adequate ventilation. If the hood is used exclusively in the recirculation mode, the unrestricted operation is possible.
WARNING
Fire hazard from flying sparks. Only install equipment on a fireplace for
solid fuels (for example, wood or coal), if a closed, non-removable cover is
available.
INSTALLATION
Preparation
If you have an outlet to the outside, your cooker hood can be connected as
below picture by means of an extraction duct (enamel, aluminum, flexible pipe,
or inflammable material with an interior diameter of150mm)
- Before installation, tum the unit off and unplug it from the outlet.
- the cooker hood should be placed data distanceof65 – lSOcmabovethe cooking plane for best effect.
Installation (Vent outside)
Note: ‘Mien the range hood and appliance supplied with energy other than electricity are simultaneously in operation, the negative pressure in the room must not exceed 4 Pa (4 x 10·5 Bar).
Dimensions
Ceiling Installation
Note: The ventilation pipe must be installed after adjusting the extractor hood.
- When mounting a non-return valve, it must be ensured that the valve can be opened freely. If the valve cannot be opened freely, it can reduce the suction power and increase the noise from the extractor hood.
- If the extractor hood is used for recirculation and there is no external ventilation (exhaust air), it is important that the ventilation is not blocked or impaired, as this can damage the extractor hood, reduce capacity and increase noise. In addition, no non-return valve can be installed in recirculation mode.
OPERATION
Control Panel and Button Functions
Setting the Lighting Colour
In standby mode, press and hold the LIGHT button to adjust the illumination
color. Use the button (3) to adjust one of the following light colors. The
lights will show the corresponding number (L1-L9):
Display | Colour | Display | Colour |
---|---|---|---|
L1 | White | L6 | Purple |
L2 | Red | L7 | Orange |
L3 | Green | L8 | Cyan |
L4 | Blue | L9 | Yellow-green |
L5 | Yellow |
TECHNICAL DATA
TROUBLESHOOTING
Fault | Cause | Solution |
---|---|---|
light on, but fan does not work | The fan blade is jammed. | Switch of the unit |
and repair by qualified service personnel only.
The motor is damaged.
Both light and fan do not work| light bulb bum.| Replace the bulb with the
correct rating.
The power cord loses.| Plug into the power supply again.
Serious Vibration of the unit| The fan blade is damaged.| Switch of the unit
and repair by qualified service personnel only.
The fan motorist fixed tightly.
The unitisnothung pro purely on the bracket.| Takedown the unit and check
whether the bracket
isin proper location.
Suction performance not good| Too long distance
between the unit and the cooking plane
| Readjust the distance to
65 – 150cm
CLEANING AND CARE
Monthly Cleaning for Grease Filter
Clean the filter every month can prevent any risk of fire. The filter collects
grease, smoke and dust, so the filter is directly affecting the efficiency of
the cooker hood. If not cleaned, the grease residue (potential flammable) will
saturate on the filter. Clean it with household cleaning detergent.
Annual Cleaning for Activated Filter
Apply solely to unit that is installed as a recirculation unit (not vented to
the outside). This filter traps odors and must be replaced at least once a
year depending on how frequently the cooker hood is used.
Replacing Bulbs
- Switch the unit off and unplug the appliance.
- Remove the lamp cover by unscrewing the 2 screws.
- Unscrew the incandescent bulb. Replace with the same type and rated bulb.
HINTS ON DISPOSAL
According to the European waste regulation, 2012/19/EU this symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead, it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local council or your household waste disposal service.
DECLARATION OF CONFORMITY
This product conforms to the following European Directives:
- 2014/30/EU (EMC)
- 2014/35/EU (LVD)
- 2011/65/EU (RoHS)
- 2009/125/EC (ERP)