Gude Pro 1100 A Water Pump Instruction Manual

June 3, 2024
Gude

Gude Pro 1100 A Water Pump - ICON Translation of the original instructionsGude Pro 1100 A Water Pump

Pro 1100 A Water Pump

Please read the instructions carefully before starting the machine.

INBETRIEBNAHME
LIEFERUMFANG

Pro 1100 A
Pro 2200 A

|

Pro 2201 S

---|---
Gude Pro 1100 A Water Pump - FIGURE 1| Gude Pro
1100 A Water Pump - FIGURE 2

Gude Pro 1100 A Water Pump - ICON 3 Service Connection

Gude Pro 1100 A Water Pump - FIGURE 3

Gude Pro 1100 A Water Pump - ICON 4Starting-up the machine

Gude Pro 1100 A Water Pump - FIGURE 4

Gude Pro 1100 A Water Pump - ICON 5Operation

Gude Pro 1100 A Water Pump - FIGURE 5

Gude Pro 1100 A Water Pump - ICON 6Oil change

Gude Pro 1100 A Water Pump - FIGURE 6

Gude Pro 1100 A Water Pump - ICON 6Cleaning / Maintenance

Gude Pro 1100 A Water Pump - FIGURE 7

Technical Data

Submersible sewage pump……………………………………………..Pro 1100 a …………………….. Pro 2200 a………………………………….Pro 2201 S
Art. No …………………………………………………………………………… 75800 …………………………….75805 …………………………….75810
Service connection ………………………………………………… 230V~50Hz …………………….230V~50Hz ……………………230V~50Hz
Motor output P1 ………………………………………………………1100 W …………………………. 2200 W ………………………. 2200 W
Max. head of delivery ………………………………………………………… 9 m ……………………………. 17 m …………………………….. 17 m
Max. immersion ………………………………………………………………… 5 m ………………………………5 m …………………………………5 m
Max. delivered quantity …………………………………………………. 19 800 l/h ………………………42 000 l/h ………………………42 000 l/h
Max. suction …………………………………………………………………….20 mm ………………………….. 20 mm ………………………….20 mm
Max. Water temperature …………………………………………………. 35°C ……………………………….35°C ……………………………..35°C
Hose connection …………………………………………………………….. 2“ IG …………………………….3“ IG ……………………………2,5“ IG
IP 68 Degree of protection ……………………………………………………….IP68 ………………………………..IP68 …………………………….. IP68
Weight ……………………………………………………………………………. 21,5 kg …………………………. 31 kg ……………………………. 31 kg

Read and understand the operating instructions before using the appliance. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties.
In case of any doubts about connection and operation refer please to our customer center

Specified Conditions of Use

The pump is solely used for drainage and for pumping into and out of containers in the house, garden, farm, and agriculture and only for water. Respecting technical data and safety precautions.
Do not use this product in any other way than stated for normal use. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages.

The pump is not suited for long-run operation (e.g. as a circulation pump in ponds or streams). When used in this manner, its service life is curtailed correspondingly. In these cases, then, use a time switch to secure sufficient idle periods between cycles of operation.
Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
Do not use the pump for drinking water!
The pump must not be used to pump wastewater.

Safety Instructions

Warning!
Electric shock! There is a risk of an injury caused by electric shock!
This device is not intended for use by persons (including children) with limited physical, sensory or mental capabilities or without the necessary lack of experience or knowledge unless they are supervised by a person who is responsible for their safety or was instructed by that person in how to use the device.
Children should be supervised to ensure that they do not play with the device. Always keep children and unauthorized persons out of reach of the appliance.
Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA).
Before putting it into operation, a qualified electrician must check whether the electric safety measures required are in place. Any national regulations in this regard must be complied with.
Electric connection to a socket.
It is necessary to make sure the connecting socket was not near water and humidity and that the plug was protected against humidity.
Check the voltage. Technical data given on the type label must correspond with the electric network voltage.
Only use splash-proof extension cables approved for outdoor purposes.
Do not grab the feeder cable, plunge the pump, lift or carry it while it is connected to the grid!
Check the cable and/or socket for damages before the appliance putting into operation.
To avoid danger, a damaged mains supply pipe must be replaced by the manufacturer. Do not under any circumstances attempt any repair yourself.
Protect the feeder cable from excessive temperatures, oil, and sharp edges.
Unplug the device prior to submersion, upon the termination of operation, in the course of defect removal, and prior to performing maintenance procedures.
If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.).
The pump must not in any case run without fillings.
Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
The temperature of the drained liquid must not exceed +35°C.
If the lubricant escapes the fluid could become contaminated.
If the pump is used in ponds, wells, etc., and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed.
The user is responsible to third parties if a pump (dumping stations, etc.) is used.
Risk of injury around the crusher on the bottom of the pump.
Touch the appliance on the top of the handle only. Do not touch the rotating tool.

Requirements for operating staff
The operating staff must carefully read the Operating Instructions before using the appliance.
Qualification: Apart from the detailed instructions by a professional, no special qualification is necessary for appliance using.
Minimum age: Persons over 16 years of age can only work on the appliance. An exception includes youngsters trained in order to reach knowledge under the supervision of the trainer during occupational education.
Training:  Using the appliance only requires corresponding training by a professional or the Operating Instructions. No special training is necessary.

Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. For the sake of an eventual accident, in accordance with DIN 13164, a workplace has to be fitted with a first-aid kit. It is essential to replace any used material in the first-aid kit immediately after it has been used. If you seek help, state the following pieces of information:

  1. Accident site
  2. Accident type
  3. Number of injured persons
  4. Injury type(s)

Maintenance

Before carrying out any work on the machine, disconnect the plug from the socket.
Prior to every use, visually check the machine to rule out any defects, in particular on the power cable and the plug.
The machine must not be used under any circumstances if the machine or the safety devices are damaged.
Refer all servicing to customer service. Use only original accessories and original spare parts.
To ensure the long service life of the pump seal we recommend rinsing the pump with clean water at regular intervals.
During winter storage, it is necessary to make sure there is no water in the appliance as the frost could damage the appliance. Prior to transportation, it is necessary to unplug the pump from the grid! The device has to be completely emptied and stored with frost-proof protection. Adhesion of mechanical seals can be prevented if you rinse the pump with the appropriate oil (for example, vegetable oil).
Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to unforeseen accidents and injuries.
Oil products must not come into contact with skin, eyes, and clothing.
Make sure the oil products do not enter the soil.

Guarantee

Guarantee claims as per the guarantee card attached.
The guarantee solely covers inadequacies caused by material defects or manufacturing defects. An original payment voucher with the date of the sale needs to be submitted for any claim in the guarantee period.
The guarantee does not cover any unauthorized use such as appliance overloading, use of violence, or damage as a result of any unauthorized interference caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee…
GÜDE cannot be held responsible for damages incurred as a consequence of unqualified installation or unskilled handling of the pump.
The device has to be checked on a regular basis to ensure perfect functioning.
Let us refer to the fact we do not assume any responsibility – according to standards in force – for damage eventually caused by our appliances in the below-mentioned cases:• Unprofessional repairs executed by unauthorized service centers;• Use in conflict with the designed purpose, or failure to observe the use as designed;• Pump overload with a continuous run;• Damage as a result of icing or any other fault caused by climatic influences;
Identical regulations apply for accessory parts.
To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the owner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).

Service
Do you have any technical questions? Any claim? Do you need any spare parts or operating instructions? We will quickly help you without needles bureaucracy on our web pages at www.guede.com in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. All this data can be found on the type label. Please enter it here for future reference:

Serial No.:……………………………….
Art. No:………………………………….
Year of production:……………….

Symbols

**** Read the Operating Instructions
Before carrying out any work on the machine, disconnect the plug from the

socket.
| Cable pulling/transport prohibited
| Staying in the transportation medium prohibited
| Warning against dangerous electric voltage
| Warning against automatic starting
| Do not touch the rotating tool.
| 2 people are needed for implementation.
| Any damaged or disposed of electric or electronic devices must be delivered to appropriate collection centers.
Dispose of the waste oil in an environment-friendly manner!
| Protect against humidity
| This side up

EC-Declaration of Conformity

GÜDE GmbH & Co. KG
Birkichstrasse 6, 74549 Wolpertshausen
Deutschland
We, hereby declare the conception and construction of the below-mentioned appliances correspond – at the type of construction being launched – to the appropriate basic safety and hygienic requirements of EC Directives. In case of any change to the appliance not discussed with us, the Declaration expires

Plunge pump
PRO 1100 A #75800
PRO 2200 A #75805
PRO 2201 S #75810
Appropriate EU Directives
2006/95 EG, 2004/108 EG
Harmonized standards used
EN 55014-1:2006 + A1:2009
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2006 + A1:2009 + A2:2009
EN 61000-3-3:2008
EN 50366:2003 + A1:2006
EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 +
A2:2006 + A13:2008 + A14:2010
EN 60335-2-41:2003 + A1:2004 + A2:2010

Wolpertshausen, 2012-01-13
Technical documentation

Helmut Arnold
Managing Director
Joachim Bürkle

Inspection and maintenance plan

Time interval Description Any other details
As needed Cleaning and rinsing out Function check of the floating switch
After 12 months Oil change 10 W – 40, max 100 ml

Failures – causes – removal

Failures Causes Removal
The engine does not start No power supply. Blocked pump wheel
Floating switch in shutdown position Check the voltage

Visually inspect the pump wheel for foreign objects
Check the water level
The pump does not suck.| Water level too low Blocked pump wheel| Switch the pump off, the water level must go up. Remove the obstruction.
Insufficient amount of water pumped| The crusher wheel is dirty
Water level quickly drops down Maximum head of delivery exceeded Broken piping| Clean the crusher wheel Ensure sufficient inflow Check the transport line Check the transport line

GÜDE Service

Germany
Güde GmbH & Co. KG
birkichstrasse 6
D-74549 Wolpertshausen
Tel: 0049 (0)7904 700 360
Fax: 0049 (0)7904 700 51999
www.guede.com| Slovenia
TRISA d.o.o.
begunje na Gorenjskem 147
SI-4275 begunje na Gorenjskem
Tel: 00386 / 059165656
Fax: 00386 / 059165657| Bulgaria
Kolarov Technologic O.O.D.
Jordan border 4
bG-8800 Sliven
Tel: 00359 / 886568083
Fax: 00359 / 44680404
---|---|---
Austria
Güde GmbH & Co. KG
Albrechtsberg 12
AT-5270 Mauerkirchen
Tel: 0043 / 7724 70988
Fax: 0043 / 7724 70998| Hungary
Güde Hungary Kft.
Kossuth Lajos ut 72
HU-8420 Zirc
Tel: 0036 / 88575348
Fax: 0036 / 88575349| Bosnia
KT-Prom
Jankovic b. Radica 30
HR-42000 Varazdin
Tel: 00385 / 42370110
Mobil: 00385 / 915321596
Fax: 00385 / 42370110
Czech republic
Güde CZECH s.r.o
Pocernická 120
CZ-36005 Karlovy Vary
Tel: 0042 / 0353434502
Fax: 0042 / 0353434505| Croatia
KT-Prom
Jankovic b. Radica 30
HR-42000 Varazdin
Tel: 00385 / 42370110
Mobil: 00385 / 915321596
Fax: 00385 / 42370110| Switzerland
Steiner Motorgeräte
Loostrasse 3
CH-8803 Rüschlikon
Tel: 0041 / 0447243440
Fax: 0041 / 0447243442

GÜDE GmbH & Co. KG
birkichstrasse 6
74549 Wolpertshausen
Deutschland
Tel.: +49-(0)7904/700-0
Fax.: +49-(0)7904/700-250
Email: info@guede.com

Documents / Resources

| Gude Pro 1100 A Water Pump [pdf] Instruction Manual
Pro 1100 A, Pro 2200 A, Pro 2201 S, Pro 1100 A Water Pump, Pro 1100 A, Water Pump, Pump
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals