- RT500RF Programmable Room Thermostat with RF
- PRODUCT COMPLIANCE
- SAFETY INFORMATION
- ErP RATING
- INTRODUCTION
- INTRODUCTION
- Features
- INSTALLATION
- CONNECTING THE RT500RF RECEIVER
- RECEIVER WIRING TERMINALS
- TYPICAL WIRING INSTALLATIONS
- CONTROL CENTRE JUMPER SETTINGS
- RF ADDRESS CODE SETTING
- TESTING THE RF TRANSMISSION
- MULTIPLE THERMOSTAT INSTALLATIONS
- AFTER INSTALLATION
- USER INTERFACE AND CONTROLS
- USER CONTROL FUNCTION SUMMARY
- OPERATION
- SETTING THE TIME
- PROGRAMMING THE RT500RF
- 5/2 DAY MODE
- 7 DAY MODE
- FROST PROTECTION
- REVIEWING SET POINT TEMPERATURE
- TEMPORARY OVERRIDE
- OTHER FUNCTIONS AND CONTROLS
- ENERGY TIP
- MAINTENANCE
- WARRANTY
- PRODUCT SPECIFICATION
- RT500RF Warranty
- www.salus-tech.com
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
RT500RF Programmable Room Thermostat with RF
Instruction Manual
PRODUCT COMPLIANCE
SALUS Controls Plc hereby declares that the radio equipment type 868Mhz is in compliance with Directives 1999/5/EC, 2014/53/EU, 2006/95/EC, 2004/108/EC, 2011/65/EU, 2009/125/EC and 93/68/EEC. The full text of the EU declaration of conformity is available at the following internet address: www.saluslegal.com
SAFETY INFORMATION
These instructions are applicable to the SALUS Controls model stated on the
front cover of this manual only, and must not be used with any other make or
model.
These instructions are intended to apply in the United Kingdom only, and
should be followed along with any other statutory obligations.
This accessory must be fitted by a Competent person, and installation must
comply with the guidance provided in the current editions of BS7671 (IEE
Wiring Regulations) and Part ‘P’ of the Building Regulations. Failure to
comply with the requirements of these publications could lead to prosecution.
Always isolate the AC Mains supply before opening or removing the unit from
the wall or wall box.
When fitting batteries don’t mix old and new batteries together. Do not use
rechargable batteries.
Please leave these instructions with the end user where they should be kept in
a safe place for future reference.
ErP RATING
This product has been rated as: Class 1, Efficiency 1%
INTRODUCTION
What is a programmable room thermostat?
… an explanation for householders
A programmable room thermostat is both a programmer and a room thermostat. A
programmer allows you to set ‘On’ and ‘Off’ time periods to suit your own
lifestyle. A room thermostat works by sensing the air temperature, switching
on the heating when the air temperature falls below the thermostat setting,
and switching it off once this set temperature has been reached.
So, a programmable room thermostat lets you choose what times you want the
heating to be on, and what temperature it should reach while it is on. It will
allow you to select different temperatures in your home at different times of
the day (and days of the week) to meet your particular needs.
Turning a programmable room thermostat to a higher setting will not make the
room heat up any faster. How quickly the room heats up depends on the design
of the heating system, for example, the size of boiler and radiators.
Neither does the setting affect how quickly the room cools down. Turning a
programmable room thermostat to a lower setting will result in the room being
controlled at a lower temperature, and saves energy.
The way to set and use your programmable room thermostat is to find the lowest
temperature settings that you are comfortable with at the different times you
have chosen, and then leave it alone to do its job. The best way to do this is
to set low temperatures first, say 18°C, and then turn them up by one degree
each day until you are comfortable with the temperatures. You won’t have to
adjust the thermostat further. Any adjustments above these settings will waste
energy and cost you more money.
If your heating system is a boiler with radiators, there will usually be only
one programmable room thermostat to control the whole house. But you can have
different temperatures in individual rooms by installing thermostatic radiator
valves (TRVs) on individual radiators. If you don’t have TRVs, you should
choose a temperature that is reasonable for the whole house. If you do have
TRVs, you can choose a slightly higher setting to make sure that even the
coldest room is comfortable, then prevent any overheating in other rooms by
adjusting the TRVs.
The time on the programmer must be correct. Some types have to be adjusted in
spring and autumn at the changes between Greenwich Mean Time and British
Summer Time.
You may be able to temporarily adjust the heating programme, for example,
‘Override’, ‘Advance’ or ‘Boost’. These are explained in the manufacturer’s
instructions.
Programmable room thermostats need a free flow of air to sense the
temperature, so they must not be covered by curtains or blocked by furniture.
Nearby electric fires, televisions, wall or table lamps may prevent the
thermostat from working properly.
INTRODUCTION
The RT500RF from SALUS Controls is a stylish and accurate 5/2 or 7 day
programmable electronic thermostat with a large, easy to read Liquid Crystal
Display (LCD). This programmable thermostat has been specifically designed to
be used for both Volt Free and AC heating applications. This programmable
thermostat can replace most common residential thermostats and is designed to
be used with electric, gas or oil heating control systems. Unlike ordinary
single unit design thermostats, this is a new type of thermostat separating
the operational functions into two units.
The Receiver is used for wiring connections and heat on/off control. The
Control Centre provides the user interface and temperature sensing / control.
The two units are linked together by a Radio Frequency (RF) signal.
Features
- Volt free switching option
- 5/2 or 7 day programming flexibility
- Built-in start up programming for quick installation
- Frost protection
- Large, easy to read LCD with blue backlight
- Burner on symbol
- Easy to use programming
- User friendly
INSTALLATION
Please read the important safety information at the start of this manual before you begin to install the device.
The RT500RF Control Centre is easily installed using the Industry Standard back plate supplied with the unit – this is used purely for mounting purposes, as no wiring is needed for the Control Centre. The back plate can be mounted directly to the wall surface.
The ideal position to locate the RT500RF Control Centre is about 1.5m above floor level. It should be mounted in a location where the thermostat is accessible, reasonably lit and free from extremes of temperature and draughts. Do not mount the thermostat on an outside wall, above a radiator or in a location where it may be subjected to direct sunlight.
To ensure trouble free operation of the Radio Frequency (RF) signal, always ensure that the programmable thermostat is mounted away from any possible sources of interference (such as radios, TV sets, computers, etc.), and is not mounted on or in close proximity to large metal objects. Installing the RT500RF in enclosed areas such as cellars and basements is not recommended.
CONNECTING THE RT500RF RECEIVER
NOTE: All electrical installation work should be carried out by a suitably qualified Electrician or other competent person.
If you are not sure how to install this programmable thermostat consult either with a qualified electrician, heating engineer or your boiler / heating system supplier for advice on how to continue.
The RT500RF Receiver should be mounted in a suitable location that is both accessible for the connection of mains and control wiring, and allows good reception of the RF signal. The Receiver needs a 230V AC mains supply to operate, and this should be fused appropriately (13A max.). The Receiver should be mounted in a location where it will not come into contact with water, moisture or condensation.
The Receiver On/Off switch is accessible from the front face of the Receiver, as shown in this picture:
On the front cover of the Receiver you will see that there is the On/Off switch and two Light Emitting diodes (LEDs). The switch allows you to turn off the Receiver if necessary to prevent it calling for heat. The bottom LED (red) will illuminate when the switch is in the ‘On’ position and the unit is receiving power. The top LED (green) illuminates when the Receiver unit is receiving a heat call transmission from the Control Centre.
The wiring terminals and RF Address Code setting DIP switches are located the rear of the Receiver, as shown in this picture:
RECEIVER WIRING TERMINALS
Terminal | Identifier | Description |
---|---|---|
1 | NO | Normally Open [N/O] |
2 | COM | Linked Live feed (230V AC heating applications only) |
3 | L | Live Feed ( 230V AC ) |
4 | N | Neutral |
TYPICAL WIRING INSTALLATIONS
a. 230V AC Installation
Notes:
- Receiver unit should have a permanent 230V AC main supply
- Confirm that the Boiler has an external thermostat loop and is configured for 230V switching
- If the boiler has two terminals for the thermostat, remove the link from the boiler
b. 24V Installation
Notes:
- Receiver unit should have a permanent 230V AC main supply
- Confirm that the Boiler has an external thermostat loop and is NOT configured for 230V switching
- If the boiler has two terminals for the thermostat, remove the link from the boiler
CONTROL CENTRE JUMPER SETTINGS
Changes to the jumper settings should only be made by the Engineer carrying out the installation or other qualified person.
The installer should select the jumper positions required if changes need to be made to the factory default settings. These jumpers are found on the rear of the Control Centre.
Jumper | Function |
---|---|
Program | Jumper for 5-2 (factory default setting) or 7 individual days |
programming.
Span| Movable jumper for selecting temperature span of ± 0.5°C (factory
default setting) or ± 1.0°C
1,2,3,4,5| Removable jumpers for altering the RF address code when used in
conjunction with the corresponding DIP switch on the Receiver.
NOTE: The Reset button must be pressed after changing jumper positions.
RF ADDRESS CODE SETTING
If there is another unit being used nearby, e.g. in the next house or as part of a multiple installation, your Receiver may be fault triggered by the other Control Unit. You can change the RF Address Code to help prevent this problem.
Each Receiver can only respond to RF transmissions from a Control Centre that has the same RF address code setting.
Disconnect any AC power to the Receiver, and remove the batteries from the Control Centre before attempting any adjustment of the RF Address Code switches and jumpers. If you are not sure how to carry out this operation correctly, consult either with a qualified electrician or heating engineer.
To adjust the RF address code of the Receiver, simply push up one or more of the 5 DIP switch levers on the DIP switch bank located on the back of the receiver (the levers are numbered 1 to 5 from bottom to top, as shown in the picture below), and then make a note of the setting of each switch:
To adjust the RF address code of the Control Centre, remove one or more of the jumper caps located on the back of the unit (labelled 1,2,3,4 and 5, and shown in the picture below) so that the jumper settings match the settings made on the receiver:
For example, if the DIP switches on the Receiver were set as follows:
1 – ON
2 – OFF
3 – OFF
4 – OFF
5 – ON
Then you would need to remove jumper caps 2, 3 and 4 on the Control Centre to make sure that they are both set with the same RF address code. Please make sure that you keep any of the jumper caps you remove in a safe place, in case you later need to change the RF address setting again.
You must press RESET on the Control Centre after making any changes to the RF address code settings.
TESTING THE RF TRANSMISSION
It is important to site both the Receiver and Control Centre in locations where the RF signal cannot be interrupted.
The receiving range between Control Centre and Receiver is approximately 30 metres indoors, however many factors can affect the RF transmission and shorten the operating distance, e.g. shielding by thick walls, foil back plasterboard, metal objects such as filing cabinets, general RF interference, and so on.
The range is generally large enough for most household applications, but it is advisable to test the RF transmission from the intended Control Centre location to the Receiver location before fixing the Control Centre to the wall. To check the RF reception, follow the following steps:
- Press the UP button on the Control Centre until the set point temperature is higher than room temperature by a few degrees.
- Wait for a few seconds. The Burner on (heat call) indicator should appear on the bottom left of the LCD on the Control Centre.
- Check the green LED on the receiver unit – it should be lit.
- Press the DOWN button to adjust the set point temperature to be lower than room temperature.
- Wait for a few seconds, and the Burner on (heat call) indicator should disappear and the green LED should switch off.
- If at step 3 the green LED is not illuminated, press the RESET button on the Control centre and try to place the Control Centre closer to the Receiver.
- Repeat steps 1 to 5.
If you are unable to get a stable RF connection between the Receiver and Control Centre, check that the Receiver is both switched on and has a mains supply (red LED lit). If this isn’t the problem you can also alter the RF address code by following the ‘RF Address Code Setting’ section of this manual, and then repeat steps 1 to 5 (note that the RESET button on the Control Centre should be pressed after altering the address code).
MULTIPLE THERMOSTAT INSTALLATIONS
If you are using more than one RT500RF programmable thermostat in the same installation, be sure that there is at least a 1 metre gap between receiver units to avoid crosstalk and other RF interference.
When installing multiple thermostats, you should assign different RF address
codes for each RT500RF by following the instructions in the ‘RF Address Code
Setting’ section of this manual. Each RT500RF should be introduced to the
installation one at a time with all other Receiver units switched off. Also
make sure that the batteries are removed from all other Control Centres.
Install each unit following the ‘Testing the RF Transmission’ section above –
once you are happy with the operation of one unit you can install the next.
Once all the RT500RF units have been installed, if one unit then seems to
function abnormally, try changing the RF address code of that unit’s Control
Centre and its corresponding Receiver, making sure that the new RF address
code is different to all others in the installation.
The control centre sends RF On/Off signals every 10 minutes to ensure the
Receiver is in the correct state. If for some reason the first RF signal is
interrupted you may notice the Control Centre has stopped or started calling
for heat but the Receiver hasn’t switched. Simply wait 10 minutes until the
next RF signal is transmitted and the receiver unit should then switch
correctly.
AFTER INSTALLATION
The following table shows the settings of the RT500RF programmable thermostat after Power on, or after RESET is pressed:
Function | Status After Reset or Power On |
---|---|
Operation Mode | Normal mode |
Room Temperature | 22.0 °C, updated within 5 seconds |
°C indicator | On |
Clock | 12:00 |
AM/PM indicator | AM |
Day of Week indicator | M |
Program | Default factory setting |
Set Point Temperature | Default factory setting |
Program Number indicator | 1 |
SET indicator | Off |
PROG indicator | Off |
Frost Protection indicator | Off |
Heat indicator | Off |
Low-Battery Warning indicator | Off, updated within 5 seconds |
Output Relay | Off |
After Power on, the thermostat will operate in Normal mode (Normal mode is when the thermostat is displaying the room temperature):
- The set point temperature is reset to the default setting
- The room temperature display is updated within 5 seconds
- The control process starts
- The programme number is updated to indicate the running program
If the Reset Button is pressed, the RT500RF will behave in the same way as described above, except that any previously saved user settings stored in the internal memory will be deleted and overwritten with the default settings, and all programmable thermostat control settings will be returned to default values.
USER INTERFACE AND CONTROLS
The status and operation of the RT500RF is clearly shown on the large backlit Liquid Crystal Display (LCD).
This display allows the user to see at a glance the current status of the
heating system, the current time and day of the week, as well as a clear
indication of the current room temperature.
There are few user controls for the RT500RF, making the programmable
thermostat very easy to operate. These controls are shown below, along with a
description of each of their functions.
USER CONTROL FUNCTION SUMMARY
OPERATION
The RT500RF is configured and adjusted by the use of a minimal number of user controls, and an intuitive user interface.
The backlit Liquid Crystal Display (LCD) gives a highly visible, easily readable indication of the programmable thermostat status.
SETTING THE TIME
Press and hold SET and SELECT when the RT500RF is in Normal mode for a few seconds to enter the Clock setting mode. Release both keys and the display will look like the image below:
The Time and Day are displayed along with a SET indicator, with all other indicators cleared from the display. The hour part of the time is flashing to indicate that it is the currently selected item and is ready to be adjusted.
- Press the UP or DOWN keys to increase or decrease the ‘hour’ setting –the selected item will stop flashing while a key is pressed, and will resume flashing when you release the key.
- Press the SELECT key to select the ‘minutes’ section of the time. Set the minutes in the same way as the hour by using the UP and DOWN keys.
- Press SELECT again to select the Day, and again change the setting with the UP and DOWN keys.
- Press the SET key to confirm the new time and day settings. This will store the changes and return the RT500RF to Normal mode.
The RT500RF Control Centre will also return to Normal mode (and save the
PROGRAMMING THE RT500RF
The RT500RF offers great versatility with its programming options, allowing
the user to programme the unit to operate on a 5/2 or 7 day control cycle. The
programmable thermostat has a default set of Programmes that have been
designed to meet the needs of most users. If these default programmes are not
suitable for your particular situation, reprogramming the RT500RF with your
own settings is a very straightforward operation.
Selection of the default programming mode (5/2 or 7 day) is made by changing
the jumper setting on the rear of the RT500RF Control Unit, as previously
described within the Installation section of this manual.
5/2 DAY MODE
5/2 day mode is the default programming mode for the RT500RF. With this mode
selected, five different sets of time and set point temperatures can be set
for Weekdays or Weekends.
To review or change a programme, press the SET key when the RT500RF is in
Normal mode. This will change the unit status to Programme Setting mode.
The LCD display will display programme number 1 and SET PROG, with all other
indicators cleared. The weekdays will be flashing to indicate they are the
selected item and are ready to be adjusted:
Press the UP or DOWN key to select the programme set for either Weekday or Weekend to be reviewed or adjusted. Pressing the SET key at any time when in programming mode will return the RT500RF into Normal mode.
Press the SELECT key to confirm the Weekday or Weekend selection. Once this is set, the ‘Hour’ will flash to indicate that it is the selected item and is the next item to be adjusted:
Press the UP or DOWN key to adjust the hour setting to the desired value, and confirm your selection by pressing the SELECT key.
Pressing the SELECT key allows you to step through each of the items to be reviewed or adjusted within the programmes in the following sequence:
Programme | Function Sequence |
---|---|
1 | Hour |
2 | Hour |
3 | Hour |
4 | Hour |
5 | Hour |
…before then allowing you to cycle back to Programme 1. Pressing the SET key at any time will confirm the setting and return to the programme set selection.
7 DAY MODE
The RT500RF also offers a 7 day programming mode, which allows you to
programme five different sets of time and set point temperatures for each day
of the week to give a total of 35 separate programme settings.
To review or change a programme, press the SET key when the RT500RF is in
Normal mode. This will change the unit status to Programme Setting mode.
The LCD display will display programme number 1 and SET PROG, with all other
indicators cleared. The weekdays will be flashing to indicate they are the
selected item and are ready to be adjusted.
Press the UP or DOWN key to change the display to indicate the single day you want to programme:
Pressing the SET key at any time when in programming mode will return the RT500RF into Normal mode. Press the SELECT key to confirm the Day selection. Once this is set, the ‘Hour’ will flash to indicate that it is the selected item and is the next item to be adjusted:
Press the UP or DOWN key to adjust the hour setting to the desired value, and confirm your selection by pressing the SELECT key.
Pressing the SELECT key allows you to step through each of the items to be reviewed or adjusted within the programmes in the following sequence:
Programme | Function Sequence |
---|---|
1 | Hour |
2 | Hour |
3 | Hour |
4 | Hour |
5 | Hour |
…before then allowing you to cycle back to Programme 1. Pressing the SET key at any time will confirm the setting and return to the programme set selection. Each programme for all the other days of the week is set in exactly the same way – just repeat the steps shown above, after entering programming mode and selecting the day you want to programme.
Regardless of which programming mode the RT500RF is set for (5/2 or 7 day), not pressing any keys for 15 seconds will automatically save any programming changes and exit to Normal mode. You can also review or change programme settings when Frost Protection is enabled.
FROST PROTECTION
To enable the Frost Protection mode, press and hold the BACKLIGHT / FROST
button for three seconds with the RT500RF in Normal mode. Once Frost
Protection is enabled, the set point temperature is automatically set to 5°C
to provide protection from the risk of freezing.
Whenever Frost Protection is activated, the Frost Protection indicator will
flash in the sequence shown below:
While Frost Protection is activated, it will override any programme settings until the mode is changed. To turn off Frost Protection mode, press and hold the BACKLIGHT / FROST button for three seconds.
REVIEWING SET POINT TEMPERATURE
You can view the set point temperature at any time by pressing either the UP or DOWN key.
When any programme is running, the LCD display will show the programme set point temperature with the SET indicator displayed:
When operating in Frost Protection mode, the LCD display will show a reading of 5 °C and also display the Frost Protection indicator:
When operating in Temporary Override mode, the LCD display will show the temporary set point temperature:
To exit from the set point review, press any key except the UP or DOWN keys, or don’t press any keys for approximately four seconds – either of these actions will return the RT500RF to Normal mode.
TEMPORARY OVERRIDE
It is possible to temporarily override the current set temperature of the RT500RF. There are two ways to do this:
- While reviewing set point temperature: Pressing the UP or DOWN key while reviewing the set point temperature will increase or decrease the set point temperature in 0.5 °C steps.
- In Normal mode: press and hold either the UP or DOWN key to display the set point temperature. After two seconds, the RT500RF will enter Temporary Override mode and allow increase or decrease of the set point temperature. If the key is released within two seconds then you will only be able to review the set point temperature.
Once in Temporary Override mode, the clock and day are displayed, along with the SET indicator; all other indicators are cleared from the display. The set point temperature will flash to indicate that it can be changed:
Pressing the UP or DOWN key will increase or decrease the set point
temperature in 0.5 °C steps – the set point temperature can be adjusted within
a set range or 10 °C to 35 °C.
You can press SET at any time to confirm the new Temporary Override setting
and return to Normal mode, or press no keys at all and wait approximately four
seconds.
Temporary Override mode remains active until the clock or programme settings
are adjusted, Frost Protection is activated or the next programme time /
temperature set point is reached.
OTHER FUNCTIONS AND CONTROLS
Backlight
The backlight of the RT500RF is switched on automatically whenever any of the
keys are pressed. The backlight will remain illuminated for approximately 5
seconds after the last key press, except if you are changing settings within
the Clock, Programme or Temporary Override modes – in this case, the backlight
will remain illuminated throughout the setting change process. The backlight
will not illuminate if the RT500RF battery is low.
Battery Status
The RT500RF checks the battery voltage frequently during normal operation. If
the battery voltage is sensed as being low (this is normally when the battery
voltage falls to a level of around 2.6V), the low battery indicator will be
displayed on the screen.
Although the programmable thermostat will continue to operate normally at this stage, you should replace the batteries as soon as possible to prevent any possible operating problems.
Reset Button
The Reset Button is provided as a way to restore the programmable thermostat
to its default factory settings. Pressing this button will delete any
previously entered settings.
Sleep Mode
By pressing both the UP and DOWN keys together, the RT500RF will enter SLEEP
mode. In this mode, all the RT500RF functions will be paused to save battery
power, with the exception of the clock which will continue to run in the
background.
While in SLEEP mode:
- The LCD display will be blank.
- All output from the Control Unit will be turned off immediately. Press any key to wake up the RT500RF and cancel SLEEP mode.
ENERGY TIP
One way to set and use your room thermostat is to find the lowest temperature setting that you are comfortable with, and then leave it set at this temperature. You can do this by setting the room thermostat to a low temperature, (for example 17 °C) and then increasing the setting by one degree each day until you are comfortable with the room temperature – you won’t have to adjust the thermostat further, as adjustment above this setting will waste energy – a 1 °C increase in temperature is equal to 3% of your heating costs.
MAINTENANCE
The RT500RF programmable thermostat requires no special maintenance.
Periodically, the outer casing can be wiped clean using a dry cloth (please DO
NOT use solvents, polishes, detergents or abrasive cleaners, as these can
damage the thermostat).
There are no user serviceable parts within the unit; any servicing or repairs
should only be carried out by SALUS Controls or their appointed agents.
Should the RT500RF programmable thermostat fail to function correctly, check:
- The batteries are the correct type, fitted correctly and are not exhausted – fit new batteries if in doubt.
- Heating system is switched on.
- The RT500RF Receiver is switched on.
- If the RT500RF is still not functioning correctly, press the Reset Button.
WARRANTY
SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of two years from the date of purchase. SALUS Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
PRODUCT SPECIFICATION
Model: RT500RF
Type: Electronic programmable thermostat, designed for Volt Free and AC
heating applications.
Frequency: 868 MHz
Programming
Programming Modes: User selectable for 5/2 or 7 day option
Number of Programmes: Five (5) user programmes plus factory default
programme.
Override Facility: User selectable programme override facility.
Default Programmes
Programme | Output | Weekday | Weekend |
---|---|---|---|
1 | ON | ||
TEMP | 6:00 AM | ||
21 ºC | 6:00 AM |
21 ºC
2| ON
TEMP| 8:00:00 AM
14 ºC| 8:00 AM
21 ºC
3| ON
TEMP| 4:00 PM
21 ºC| 4:00 PM
21 ºC
4| ON
TEMP| 6:00 PM
21 ºC| 6:00 PM
21 ºC
5| ON
TEMP| 10:00 PM
14 ºC| 10:00 PM
14 ºC
Temperature
Scale: Celsius
Range: 5 ºC to 35 ºC
Resolution: 0.5 ºC
Tolerance: Less than ± 0.5 ºC at 25 ºC
Display Range: 5.0 ºC to 45.0 ºC
Display Resolution: 0.5 ºC
Clock
Accuracy: ± 1 minute per month
Display: 12 hour
Frost Protection
Setting: 5 ºC
Setpoint Temperature Range: 5 ºC to 35 ºC
Measured Air Temperature Range: 5 ºC to 45 ºC (Displayed on LCD)
If room temp is higher than 45C,will show HI on the LCD, if less than 5C will
show LO on the LCD
Control Centre
Power Source: 2 x AA alkaline batteries (don’t use rechargeable
batteries)
Receiver
Power Source: 230V AC / 50Hz
Switch Rating
Switching Voltage: 0 – 230V AC / 50Hz
Switching Current: 16A resistive, 5A inductive
Protection Rating: IP30
Environment
Operating Temperature: 0 ºC to + 40 ºC
Storage Temperature: – 10 ºC to + 60 ºC
RT500RF Warranty
SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of two years from the date of purchase. SALUS Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
www.salus-tech.com
Sales: Email: sales@salus-tech.com Tel: 01226 323961
Technical: Email: tech@salus-tech.com Tel: 01226 323961
SALUS Controls plc, SALUS House, Dodworth Business Park South,
Whinby Road, Dodworth, Barnsley S75 3SP
Read User Manual Online (PDF format)