INTRODUCTION

Your Ebac Dehumidifier is designed to help dry flooded or damp areas. Ideal where natural drying is just too slow. Drying with a dehumidifier enables fast drying without problems assosiated with heat drying plaster, etc can crack

IMPORTANT

Your Ebac Dehumidifier is packed in a plastic wrapper – please ensure that it is disposed of safely and where it will not be a danger to children

HOW YOUR DEHUMIDIFIER WORKS

Your dehumidifier draws in the moist air, cooling it to a temperature where excess moisture will condense, thereby removing the excess moisture. This in turn dries anything in the immediate area which is damp. The moisture is collected via a drip tray and drained via a drainage hose. The air is rewarmed and passed back approximately 2°C warmer.

OPERATING YOUR DEHUMIDIFIER

The amount of moisture removed by your dehumidifier will vary according to the conditions in which it is operating. For example, operating in very cold temperatures will reduce water extraction levels. The time taken to dry an area will depend on the size of area to be dried and level of moisture to begin with. To achieve maximum benefit form your dehumidifier, you should ensure :-

  • a) It is permanently connected to the mains
  • b) Door to areas not to be dried are kept closed.
  • c) External doors and windows are kept closed as much as possible

SWITCHING ON YOUR DEHUMIDIFIER

Simply connect the dehumidifier to a standard 230V mains supply and switch the supply on. The unit will then start immediately. To protect the compressor, you should allow 5 minutes between switching the dehumidifier off and on again.

DEFROST OPERATION

At certain temperatures, the water taken freezes onto the pipes inside your dehumidifier and therefore needs to be defrosted. This model features an automatic defrost which will clear any ice build up.

DRAINAGE

Your dehumidifier will continuously remove water when turned on. This means water will be continuously flowing from the drainage tube. This must be collected into a water container or connected to a permanent drain at all times when running the unit. The drainage tube must not be higher than the level of the drain tray or flooding may occur. If connected to a container it must be monitored and emptied as required.

IF YOUR DEHUMIDIFIER FAILS TO OPERATE

1. Check that the plug is fully pushed into the socket and is switched on.
2. Check with some other electrical device that the wall socket is “live”. If it is not, contact a qualified electrician.
3. Check the fuse in the plug. If you replace the fuse, refit with a 13Amp fuse. Should none of the above remedies work, then disconnect from the mains. Contact the help line on 01388 664400. DO NOT attempt to repair the unit or unscrew the outer casing. Your Ebac Dehumidifier is packed in a plastic wrapper – please ensure that it is disposed of safely and where it will not be a danger to children

 ELECTRICAL CONNECTION

If the appliance is fitted with a plug for which your socket is unsuitable, then it should be cut off and an appropriate plug fitted. This appliance complies with the suppression requirements of the EEC direction 82/199/EEC as embodied in BS800:1988.IMPORTANT:- The wires in this mains lead are coloured in accordance with the following code:-

  • Green & Yellow Earth
  • Blue Neutral
  • Brown Live

As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your own plug, proceed as follows: The wire which is coloured Green and Yellow must be connected to the terminal in the plug which is marked with the letter E or by the Earth Symbol or coloured Green and Yellow. The wire which is coloured Blue must be connected to the terminal in the plug which is marked with the letter N or coloured Black. The wire which is coloured Brown must be connected to the terminal which is marked with the letter L or coloured Red. You must dispose of the non rewireable plug once it has been removed from the flexible cord. It is dangerous to attempt to insert the plug into any electrical socket elsewhere in the house. If the flexible cord becomes damaged it must be replaced by an identical cord.

CHANGING THE FUSE

Only 13 Amp fuses that are ASTA approved to BS1362 should be used The fuse cover must be refitted after replacemen of the fuse. In the event of the fuse cover bein lost or damaged, the plug must not be used until a replacement is obtained. Replacement fuse covers, which must be coloured BLACK, are obtainable from electrical retailers.

WARNING – THIS APPLIANCE MUST BE EARTHED

  •  This machine should be serviced by qualified Ebac personnel or other persons having technical competence servicing refrigeration equipment following the instructions in the Ebac service manual.
  •  Spares lists are available upon request by contacting your local Ebac distributor.
  •  Never operate the unit in a bathroom or swimming pool area
  •  Do not use the machine if the power cord or cabinet are damaged.
  •  Do not poke objects into and of the grilles on the machine.
  •  Do not cover or obstruct the air inlet or outlet.
  •  This machine complies with the electromagnetic compatibility 1992 regulations.
  •  This machine has been manufactured in the United Kingdom.
  •  Ensure this unit is protected by a 15A Circuit

TECHNICAL SPECIFICATIONS

  • ECO60 230V/50Hz/1 Phase
  • Height 590mm
  • Width 510
  • Depth 420 mm
  • Weight 35 kg
  • Min Operating Temperature 5 °C
  • Max Operating Temperature 35 °C
  • Max Power Consumption 700 W
  • Max Running Current 3.5 A
  • Fuse Rating (UK) 13 A

UK Head Office

  • Ebac Industrial Products Ltd

  • St Helens Trading Estate

  • Bishop Auckland

  • County Durham

  • DL14 9AD

  • Tel: +44 (0) 1388 664400

  • Fax: +44 (0) 1388 662590
    www.eipl.co.uk

  • [email protected]

American Sales Office

  • Ebac Industrial Products Inc
  • 700 Thimble Shoals Blvd.
  • Suite 109, Newport News
  • Virginia, 23606-2575
  • USA
  • Tel: +01 757 873 6800
  • Fax: +01 757 873 3632
  • www.ebacusa.com
  • [email protected]

German Sales Office

  • Ebac Industrial Products Ltd.
  • Gartenfelder Str. 29-37
  • Gebäude 35
  • D-13599, Berlin
  • Germany
  • Tel: +49 3043 557241
  • Fax: +49 3043 557240
  • www.eip-ltd.de
  • [email protected]

Get In Touch

Call: 0845 6880112
Email: [email protected]

Our Address

Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Ebac User Manuals

Related Manuals