Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and if the laser device is passed on, this document must be passed on with it.

Automatic laser with horizontal 360° laser circle, vertical line, and

slope function

  • The horizontal laser line creates a continuous 360° laser line with the vertical lines aligned perpendicular to it. Ideal for almost any alignment job.
  • Individually switchable laser lines
  • Out-Of-Level: is indicated by optical signals when the unit is outside its self-leveling range.
  • Additional slope function to align angled surfaces.

General safety instructions

  • The device must only be used in accordance with its intended purpose and within the scope of the specifications.
  • The measuring tools and accessories are not toys. Keep out of reach of children.
  • Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
  • Do not expose the device to mechanical stress, extreme temperatures, moisture, or significant vibration.
  • The device must no longer be used if one or more of its functions fail or the battery charge is weak.

Safety instructions

Using class 2 lasers

Attention: Do not look into the direct or reflected beam.

  • Do not point the laser beam towards persons.
  • If a person‘s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
  • Under no circumstances should optical instruments (magnifying glass, microscope, binoculars) be used to look at the laser beam or reflections.
  • Do not use the laser at eye level (1.40 … 1.90 m)
  • Reflective, specular or shiny surfaces must be covered whilst laser devices are in operation.
  • In public areas shield off the laser beam with barriers and partitions wherever possible and identify the laser area with warning signs.

Safety instructions

Dealing with electromagnetic radiation

  • The measuring device complies with electromagnetic compatibility regulations and limits in accordance with the EMC Directive 2014/30/EU.
  • Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.

Special product features

Automatic alignment of the device with a magnetically dampened pendulum system. The device is brought into the initial position and aligns itself autonomously.
Transport LOCK: The device is protected with a pendulum lock during transport.
RX-READY technology enables line lasers to be used even in unfavorable light conditions. The laser lines pulsate at a high frequency and this can be picked up by special laser receivers over long distances.

Number and direction of the lasers

  • H = horizontal laser
  • V = vertical laser
  • S = slope function

When transporting always switch off all lasers, secure the pendulum and set the slide switch to „OFF“!

Inserting batteries

  • Open the battery compartment and insert batteries (4 x type AA) according to the symbols. Be sure to pay attention to polarity.

OVERVIEW

Laserliner-SmartLine-Laser-360-Bonus-Set-Cross-LineLaser-Self-Levelling-
Range-FIG-5

  1. Laser output windows

  2. Battery compartment (back side)

  3. Slide switch

  4. ON

  5. OFF / Transport lock / Slope mode

  6. 5/8” tripod threads (bottom)

  7. LED leveling
    red: leveling off
    green: leveling on

  8. Laser line selection button; Hand receiver mode on / off

  9. LED hand receiver mode.

Horizontal and vertical leveling

Laserliner-SmartLine-Laser-360-Bonus-
Set-Cross-LineLaser-Self-Levelling-Range-FIG-6

  • Release the transport restraint, and set slide switch (3) to „ON“. The laser cross will appear. The laser lines can be switched with the selector button.

The transport restraint must be released for horizontal and vertical leveling. The laser lines flash and the LED lights red as soon as the device is outside the automatic leveling range of 5°. Position the device such that it is within the leveling range. The LED switches back to green and the laser lines stop flashing (steady light).

Hand receiver mode

Optional: Working with the laser receiver RX

Use an RX laser receiver (optional) to carry out leveling at great distances or when the laser lines are no longer visible. To work with a laser receiver, switch the line laser to hand-held receiver mode by keeping button 6 (handheld receiver mode on / off) pressed. The laser lines will now pulsate with high frequency, making the laser lines darker. The laser receiver can detect these pulsating laser lines.

  • Observe the laser receiver‘s operating instructions for line lasers.
  • Due to the special optics required to generate a continuous 360° laser line, the underlying technology may cause differences in brightness in different areas of the line. This may lead to different ranges in hand receiver mode.

Slope mode

Do not release the transport restraint, set slide switch (3) to „OFF“. Select and switch on the laser with the selection button. Sloping planes can now be measured. This mode cannot be used to perform horizontal or vertical leveling as the laser lines are no longer aligned automatically. The LED lights are constantly red.Laserliner-SmartLine-Laser-360-Bonus-Set-Cross-LineLaser-
Self-Levelling-Range-FIG-8

Preparing the calibration check

It is possible for you to check the calibration of the laser. To do this, position the device midway between 2 walls, which must be at least 5 m apart. Switch the device on (Laser cross ON). The best calibration results are achieved if the device is mounted on a tripod.

  1. Mark point A1 on the wall.
  2. Turn the device through 180° and mark point A2. You now have a horizontal reference between points A1 and A2.

Performing the calibration check

  1. Position the device as near as possible to the wall at the height of point A1.
  2. Turn the device through 180° and mark point A3. The difference between points A2 and A3M is the tolerance.
  • When A2 and A3 are more than 0.4 mm / m apart, an adjustment is necessary.
  • Contact your authorized dealer or else the UMAREX-LASER LINER Service Department.

Checking the vertical line

Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5 m length on the wall, making sure that the bob can swing freely. Switch on the device and align the vertical laser to the plumb line. The precision is within the specified tolerance if the deviation between the laser line and the plumb line is not greater than ± 2 mm.

Checking the horizontal line

Position the device about 5 m from a wall and switch on the cross laser. Mark point B on the wall. Turn the laser cross approx. 2.5 m to the right and mark point C. Check whether the horizontal line from point C is level with point B to within ± 2 mm. Repeat the process by turning the laser to the left.

  • Regularly check the calibration before use, after transport, and after extended periods of storage.

Calibration

  • The meter needs to be calibrated and tested on a regular basis to ensure it produces accurate measurement results. We recommend carrying out calibration once a year.

Information on maintenance and care

  • Clean all components with a damp cloth and do not use cleaning agents, scouring agents, or solvents. Remove the batteries) before storing for longer periods. Store the device in a clean and dry place.

Technical data

Self­levelling range| ± 5°
Accuracy| ± 0.4 mm / m
Levelling| automatic
Operating range| (depending on room illumination) 20 m
Working range with hand receiver| (depends on how the technology affects the difference in brightness) 40 m
Laser wavelength| 635 nm
Laser class| 2 / < 1 mW (EN60825­1:2014)
Power supply| 4 x 1,5V LR6 (AA)
Operating time| approx. 35 hours
Operating conditions| 0°C … 40°C, max. humidity 80% rH, no condensation, max. working altitude 4000 m above sea level
Storage conditions| ­10°C … 70°C, max. humidity 80% rH
Dimensions (W x H x D)| 105 x 126 x 76 mm
Weight| 525 g (incl. batteries)

EU directives and disposal

This device complies with all necessary standards for the free movement of goods within the EU. This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.

Further safety and supplementary notices at: http://laserliner.com/info?an=AFD

Laserliner-SmartLine-Laser-360-Bonus-Set-Cross-LineLaser-Self-Levelling-
Range-FIG-12

SERVICE

Umarex GmbH & Co. KG

  • Laserliner
  • Möhnestraße 149, 59755 Arnsberg, Germany
  • Tel: +49 2932 638-300, Fax: +49 2932 638-333
  • [email protected]

Umarex GmbH & Co. KG

  • Donnerfeld 2
  • 59757 Arnsberg, Germany
  • Tel: +49 2932 638-300, Fax: -333
  • www.laserliner.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Laserliner User Manuals

Related Manuals