Operating Instructions and Owner’s Manual
MR. HEATER
Model
MH170FAVT
PA170FAVT (with thermostat)
TS170FAV (without thermostat)
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has not read these instructions to assemble, light, adjust or operate the heater.
HEATSTAR
FORCED-AIR PROPANE CONSTRUCTION HEATER
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
- Do not try to light appliance.
- Extinguish any open flame.
- Shut off gas to appliance.
- Service must be performed by a qualified service agency
This is an unvented gas-fired portable heater. It uses air (oxygen) from the
area in which it is used.
Adequate combustion and ventilation air must be provided. Refer to page 3.
WARNING: YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER
GENERAL HAZARD WARNING:
**** FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
**** ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
**** IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.
WARNING: NOT FOR HOME OR RECREATIONAL VEHICLE USE
WARNING: FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.
The State of California requires the following warning:
WARNING: COMBUSTION BY-PRODUCTS PRODUCED WHEN USING THIS PRODUCT CONTAIN CARBON MONOXIDE, A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS (OR OTHER REPRODUCTIVE HARM)
SPECIFICATIONS
- MODEL NO..170FAVT
- GAS TYPE..Propane
- BTU RATING..125,000-170,000 BTU/hr (36.6 – 49.8 kW)
- GAS SUPPLY PRESSURE TO REGULATOR ..
- Maximum: Bottle Pressure, Minimum: 5 psig (34.5 kPa)
- REGULATOR OUT..28” WC (6.97 kPa)
- ELECTRICAL INPUT.. 115V, 60 Hz, 1Ø, 3a
- IGNITION.. Direct Spark, interrupted type
- PRIMARY FLAME CONTROL.. SolidState,10-15 sec. timing
- HIGH TEMPERATURE CONTROL.. 240°F (116°C)
- Minimum Ambient Temp. Rating: 0°F (-17.8°C)
- FUEL CONSUMPTION .. 5.8 – 7.9 lbs/hr (2.6 – 3.6 kg/hr)
- Fuel Orifice Port No.: ..18
- Fuel Orifice Port Size :.. 0.80mm favt 0.82 mm fav
- Heated Air Output: .. 450 CFM (12.74 cu m/m)
OPERATING PRECAUTIONS
This is a propane, direct-fired, forced air heater. It’s intended use is primarily temporary heating of buildings under construction, alteration or repair.
Propane is heavier than air. If propane leaks from aconnection or fitting, it
sinks to the floor, collecting therewith the surrounding air, forming a
potentially explosive mixture. Obviously, propane leaks should be avoided, so
set up the propane supply with utmost care. Read enclosed Odor
Fade and Propane Sheet for additional information about detecting propane
leaks. Leak check new connections or reconnections with a soap and water
solution and follow all connection instructions herein. Also, ask your propane
dealer for advice on the propane application and supply installation and ask
him to check it if there are any questions.
This heater was designed and certified for use as a construction heater in accordance with ANSI Standard Z83.7/ CGA 2.14-2000. Check with your local fire safety authority if you have any questions about your applications. Other standards govern the use of fuel gases and heat producing products in specific applications. Your local authority can advise you about these.
Direct-Fired means that all of the combustion products enter the heated space. Even though this heater operates very close to 100 percent combustion efficiency, it still produces small amounts of carbon monoxide. Carbon monoxide (called CO) is toxic. We can tolerate small amounts but not a lot. CO can build up in a heated space and failure to provide adequate ventilation could result in death.
The symptoms of inadequate ventilation are:
- headache
- dizziness
- burning eyes and nose
- nausea
- dry mouth or sore throat
So, be sure to follow advice about ventilation in these operating instructions.
Forced Air means that a blower or fan pushes the air through the heater. Proper combustion depends upon this air flow; therefore, the heater must not be revised, modified or operated with parts removed or missing. Likewise, safety systems must not be circumvented or modified in order to operate the heater.
When the heater is to be operated in the presence of other people the user is responsible for properly acquainting those present with the safety precautions and instructions, and of the hazards involved.
Figure 1
VENTILATION: Minimum openings required
Heater | Opening near floor | Opening near ceiling |
---|---|---|
Forced air (170 FAVT) | 3 ft2 | 3 ft2 |
SAFETY PRECAUTIONS
- Check the heater thoroughly for damage. DO NOT operate a damaged heater.
- DO NOT modify the heater or operate a heater which has been modified from its original condition.
- Use only propane gas.
- Use only VAPOR WITHDRAWAL propane supply. If there is any question about vapor withdrawal, ask your propane dealer.
- Mount the propane cylinders vertically (shutoff valve up). Secure them from falling or being knocked over and protect them from damage.
- Locate propane containers at least (USA) 7 ft. (2.13m), (Canada) 10 ft. (3m) from the heater and do not direct exhaust toward containers.
- IMPORTANT Use only the hose and regulator assembly provided with the heater. Match the color stripe on the hangtag attached to the hose assembly with the color on the label located near the propane inlet fitting on the heater. Inspect hose assembly before each use of the heater. If there is excessive abrasion or wear, or hose is cut, replace with hose assembly listed on parts list before using heater.
- For indoor use only. Area must be well ventilated. Figure 1. (also see “Operating Precautions”).
- If at any time gas odor is detected, IMMEDIATELY DISCONTINUE operation until the source of gas has been located and corrected. Read enclosed Odor fade and Propane Sheet for additional information about detecting propane leaks.
- Install the heater such that it is not directly exposed to water spray, rain and/or dripping water.
- Maintain minimum clearance from normal combustible material (like paper). Figure 2.
- Due to the high surface and exhaust temperatures, adults and children must observe clearances to avoid burns or clothing ignition.
- Operate only on a stable, level surface.
- Do not use with duct work. Do not restrict inlet or exit.
- Use only the electrical power specified. The electrical connection and grounding must comply with National Electrical Code – ANSI/NFPA 70 (USA) and CSA C22.1 Canadian ElectricalCode, Part 1 (Canada).
- Use only a properly grounded 3-prong receptacle or extension cord.
- Do not move, handle or service while hot or burning.
- Do not adjust the heater combustion tube elevation while heater is running or hot. Adjustments to elevation should only be made after the heater has cooled to touch.
- Use only in accordance with local codes or, in the absence of local codes, with the Standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B149.1, Natural Gas and Propane Installation Code.
Figure 2: MINIMUM CLEARANCE: From normal combustible materials
Clearance: Forced Air 170FAVT
- From floor ……………………………………………….0 ft
- F rom outlet ……………………………………………..6 ft
- From sides ………………………………………………2 ft
- From top …………………………………………………3 ft
Locate 10 ft. from canvas or plastic tarpaulins or similar coverings and secure them to prevent flapping or movement due to wind action
ODOR FADE WARNING
WARNING
Asphyxiation Hazard
- Do not use this heater for heating human living quarters.
- Do not use in unventilated areas.
- The flow of combustion and ventilation air must not be obstructed.
- Proper ventilation air must be provided to support the combustion air requirements of the heater being used.
- Refer to the specification section of the heater’s manual, heater dataplate, or contact the Factory to determine combustion air ventilation requirements of the heater.
- Lack of proper ventilation air will lead to improper combustion.
- Improper combustion can lead to carbon monoxide poisoning leading to serious injury or death. Symptom of carbon monoxide poisoning can include headaches dizziness and difficulty in breathing.
FUEL GAS ODOR
LP gas and natural gas have man-made odorants added specifically for detection
of fuel gas leaks.
If a gas leak occurs you should be able to smell the fuel gas. Since Propane
(LP) is heavier than air you should smell for the gas odor low to the floor.
ANY GAS ODOR IS YOUR SIGNAL TO GO INTO IMMEDIATE ACTION!
- Do not take any action that could ignite the fuel gas. Do not operate any electrical switches. Do not pull any power supply or extension cords. Do not light matches or any other source of flame. Do not use your telephone.
- Get everyone out of the building and away from the area immediately.
- Close all propane (LP) gas tank or cylinder fuel supply valves, or the main fuel supply valve located at the meter if you use natural gas.
- Propane (LP) gas is heavier than air and may settle in low areas. When you have reason to suspect a propane leak, keep out of all low areas.
- Use your neighbor’s phone and call your fuel gas supplier and your fire department. Do not re‑enter the building or area.
- Stay out of the building and away from the area until declared safe by the firefighters and your fuel gas supplier.
- FINALLY, let the fuel gas service person and the firefighters check for escaped gas. Have them air out the building andarea before you return. Properly trained service people must repair any leaks, check for further leakages, and then relight the appliance for you.
ODOR FADING – NO ODOR DETECTED
- Some people cannot smell well. Some people cannot smell the odor of the man‑made chemical added to propane (LP) or natural gas. You must determine if you can smell the odorant in these fuel gases.
- Learn to recognize the odor of propane (LP) gas and natural gas. Local propane (LP) gas dealers will be more than happy to give you a scratch and sniff pamphlet. Use it to become familiar with the fuel gas odor.
- Smoking can decrease your ability to smell. Being around an odor for a period of time can affect your sensitivity to that particular odor. Odors present in animal confinement buildings can mask fuel gas odor.
- The odorant in propane (LP) gas and natural gas is colorless and the intensity of its odor can fade under some circumstances.
- If there is an underground leak, the movement of gas through the soil can filter the odorant.
- Propane (LP) gas odor may differ in intensity at different levels. Since Propane (LP) gas is heavier than air, there may be more odor at lower levels.
- Always be sensitive to the slightest gas odor. If you continue to detect any gas odor, no matter how small, treat it as a serious leak. Immediately go into action as discussed previously.
ATTENTION – CRITICAL POINTS TO REMEMBER
- Propane (LP) gas has a distinctive odor. Learn torecognize these odors. (Reference Fuel Gas Odor and Odor Fading sections above.
- Even If you are not properly trained in the service and repair of the heater, ALWAYS be consciously aware of the odors of propane (LP) gas and natural gas.
- If you have not been properly trained in repair and service of propane (LP) gas then do not attempt to light heater, perform service or repairs, or make any adjustments to the heater on the propane (LP) gas fuel system.
- A periodic sniff test around the heater or at the heater’s joints; i.e. hose, connections, etc., is a good safety practice under any conditions. If you smell even a small amount of gas, CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY. DO NOT WAIT!
Heater Elevation Adjustment
This heater is equiped with an elevation adjustment panel located at the exhaust end of the control box.
- Do not adjust the heater combustion tube elevation while heater is running or hot. Adjustments to elevation should only be made after the heater has cooled to touch.
- To adjust the heater combustion tube elevation, turn the adjustment screw knob counterclockwise and lift the combustion tube to desired position.
OPERATING INSTRUCTIONS
PREPARING FOR OPERATION
- Check the heater for possible shipping damage. If any is found, immediately notify the factory.
- Follow all of the “Precautions”.
- Connect the POL fitting of hose and regulator assembly to the propane cylinder by rotating the POL nut counterclockwise into the propane cylinder’s valve outlet and securely tighten with a wrench.
- Connect the hose to the heater by rotating the hose fitting clockwise.
- Securely tighten all gas connections.
- Open the cylinder’s gas valve and check all gas connections with a soap and water solution. DO NOT USE A FLAME.
- Connect power cord to well-grounded 115V, 60 Hz, 1Ø source of power.
- When using an extension cord, make certain that it is a 3-wire (grounded) cord of proper wire size.
170FAVT (WITH THERMOSTAT)
START
- Slowly open the main valve at propane cylinder to prevent excess flow check valve from closing.
- Set thermostat to full on. Heater will ignite automatically.
- Adjust ball valve on control panel to desired burn rate.
- Set thermostat to desired temperature. Heater will turn off and on automatically as the temperature varies in the heater area.
STOP
- Securely close valve on the propane cylinder.
- Continue to operate heater until all fuel in the hose has burned.
- Turn the heater thermostat to “off”. For extended shut down or in areas where the temperature is below 0°F, unplug the heater.
170FAV (WITHOUT THERMOSTAT)
START
-
Before heater ignition, always allow heater fan (blower) to run for 20 seconds to purge fuel.
-
Slowly open the main valve at propane cylinder.
-
Depress the fuel valve button to light the heater.
-
After the heater lights, keep the gas valve button depressed for 15 seconds then release and the heater will continue to operate.
-
Adjust burn rate by setting control knob to desired level.
-
Igniter continues to fire as long as power cord is plugged in.
a) Igniter sparks continually. -
No thermostat usable with these units.
STOP
- Securely close valve on the propane cylinder.
- Continue to operate heater until all fuel in the hose has burned.
- Unplug the power cord.
RESTART AFTER SAFETY SHUTDOWN
- Securely close valve at propane cylinder. Unplug heater.
- Wait 5 minutes.
- Restart following “Start” procedure
MAINTENANCE AND STORAGE
- The heater should be inspected before each use, and at least annually by a qualified person.
- Before each use, check the soft “O” ring seat at the bullnose of the POL fitting. If the “O” ring is cut, scuffed, or otherwise damaged, replace it with part number 6681.
- Turn off the gas at the LP-gas supply cylinder(s) when the heater is not in use.
- When the heater is to be stored indoors, the connection between the LP-gas supply cylinder(s) and the heater must be disconnected and the cylinder(s) removed from the heater and stored out of doors and in accordance with Chapter 5 of the standard for Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B149.1, Natural Gas and Propane Installation Code.
SERVICING
A hazardous condition may result if a heater is used that has been modified or
is not functioning properly.
When the heater is working properly:
- The flame is contained within the heater.
- The flame is essentially blue with perhaps some yellow tipping.
- There is no strong disagreeable odor, eye burning or other physical discomfort.
- There is no smoke or soot internal or external to the heater.
- There are no unplanned or unexplained shut downs of the heater.
The parts lists and wiring diagram show the heater as it was constructed. Do not use a heater which is different from that shown. In this regard, use only the hose, regulator and cylinder connection fitting (called a POL fitting) supplied with the heater. IMPORTANT Match the color stripe on the hangtag attached to the hose assembly with the color on the label located near the propane inlet fitting on the heater. Do not use alternates. For this heater, the regulator must be set as shown in “specifications”. If there is any uncertainty about the regulator setting, have it checked.
A heater which is not working right must be repaired, but only by a trained, experienced service person.
In-warranty products will be repaired with no charge for either parts or labor. Please include a brief statement indicating date, place of purchase, the nature of the problem and proof of purchase.
Out-of-warrranty products will be repaired with a charge for parts and labor.
SIZE AND CAPACITY OF PROPANE CYLINDERS
- The charts below show the approximate size of the cylinder required for these heaters. To use the chart:
- Select the lowest air temperature expected (at the bottom of the chart).
- Move straight up to time of operation desired (left side of the chart).
- Read the cylinder size required.
All heaters should have: full cylinders good air circulation no frost on cylinders
HOW MUCH HEAT DO I REQUIRE?
For economy, it is important to match input to that required. But heat
requirements often vary. For example, it usually takes a lot more heat to get
things warm than it does to keep them that way. Likewise, outside air
temperature usually changes during the day so you may need more heat at night
than you do in the daytime.
An approximation of the heat required can be found by using the chart below.
BTU’S PER HOUR REQUIRED
Cubic feet of space to be heated| Temperature Rise Required ( o
**F)*
20 o| 30 o| 40 o| 50 o**
5,000| 14,000| 20,000| 27,999| 34,000
7,000| 19,000| 28,000| 38,000| 47,000
10,000| 27,000| 40,000| 54,000| 67,000
15,000| 40,000| 60,000| 80,000| 100,000
20,000| 54,000| 80,000| 107,000| 133,000
30.000| 80,000| 120,000| 160,000| 200,000
50,000| 133,000| 200,000| 266,000| 333,000
WARNING: When using a thermostat controlled heater, its exit area should be protected from personnel and warnings posted of sudden startup.
Recommended Minimum Gauge for Cord Extensions
Wire Gauge Chart A.W.G.
Name Plate 120V Amps.| Cord Length in Feet
25| 50| 100| 150
5-6| 18| 16| 14| 12
6-8| 18| 16| 12| 10
8-12| 18| 14| 12| 10
10-12| 16| 14| 10| 8
12-14| 16| 12| 10| 8
Model #170FAVT
WIRING DIAGRAM
COLOR CODE
- B – BLACK
- L – BLUE
- G – GREEN
- O – ORANGE
- R – RED
- W – WHITE
If any original wiring as supplied by the heater must be replaced, it must be replaced with type AWG 105° C wire or its equivalent except as indicated (*type SF2-200, **SGI 250° C).
170FAVT – WIRING CHART
COLOR| LENGTH| FROM| TO
White| 7”| Valve| Terminal Block
Black| 6”| On/Off Switch| Terminal Block
Red-(Hi-Temp)| 16 1/2”| High Limit Switch| Valve
Red-(Hi-Temp)| 16 1/2”| High Limit Switch| Terminal Block
Orange| 11”| Flame Control (Ignition)| Spark Plug
Green| 7”| Flame Control (Harness)| Ground
Red| 7”| Flame Control (Harness)| Terminal Block
White| 6”| Flame Control (Harness)| Terminal Block
Black| 6”| Flame Control (Harness)| Terminal Block
Model #170FAVT (WITH THERMOSTAT) PARTS LIST
Item| Part No.| Description| Qty.| Item Part
No. Description| Qty.
---|---|---|---|---|---
1| 22248| Outer Shell| 1| 24 24340 Thermostat Mounting
Bracket| 1
2| 22272| Outer Shell – Model TS| 1| 25 22254 Thermostat
Assembly| 1
2| 22249| Middle Cylinder| 1| 26 26070 Loop Clamp, 5/16| 1
3| 22250| Orifice Assembly| 1| 27 27808 Flame Control,
Potted| 1
4| 21 46| Flame Holder Assembly| 1| 28 21036 Power Cord
Assembly| 1
5| 26168| High Limit Switch| 1| 29 28771 Terminal Board| 1
6| 23038| Orifice Nut| 1| 30 26223 Bushing Strain Relief|
1
7| 28075| Handle, plastic| 1| 31 28772 Knob, Thermostat| 1
8| 28074| Handle Mounting Clips| 2| 32 28773 Knob, Burn
Rate Adjustment| 1
9| 26010| Set Screw, Nyloc| 1| 33 22255 Control Box| 1
10| 26074| Fan| 1| 34 22273 Base, Control Box| 1
1| 22251| Motor Assembly| 1| 35 22274 Elevation Plate| 1
12| 22252| Grille, Inlet/Motor Mounting| 1| 36 22275
Elevation knob| 1
13| 26152| Hose Assembly| 1| 26375 Label, Elevation
Adjustment| 1
| 26152-20| Hose Assembly, 20’| 1| 28769 Label, Safety Precautions| 1
14| 26257| Regulator, 28” WC| 1| 28755 Label, General
Hazard Warning| 1
15| 26433| POL Excess Flow Valve| 1| 28733 Label,
Model| 1
16| 26122| Male Fitting Conn.| 1| 28731 Label,
Operating Instructions| 1
| | 3/8MPT x 3/8SAE FLR| | 26410 Label, Thermostate
Warning| 1
17| 26101| Solenoid Valve, Goyen| 1| 27704 Label,
Warning Massachusetts| 1
18| 28775| Fitting Close Nipple| 1| 26374 Label,
Warning Electrical| 1
19| 28777| Burn Rate Adjustment Valve| 1| 27789
Label, Wiring Schmatic| 1
20| 28776| Fitting, Elbow| | 28203 Label, Hang Tag| 1
| | 3/8MPT x 1/2 SAE FLR| 1| 28679 Label, BTU
170,000| 1
21| 22253| Fuel Tube Assembly| 1| 70176 Manual,
Operating Instructions| 1
2223| 2877423037| Spark Plug, Flame SensorSpark Plug Nut| 11|
26225 Snap Bushing, 5/8* Item not shown on exploded view| 2
Model #170FAV (WITHOUT THERMOSTAT) WIRING DIAGRAM
CONNECTION DIAGRAM
SCHEMATIC DIAGRAM
COLOR CODE | LEGEND |
---|---|
B BLACK | R RED |
Y YEL | RING CONN. |
W WHITE | O ORG |
G GREEN |
NOTE: If any original wiring as supplied with the heater, must be replaced, It must be replaced with Type AWG 105° C wire or its equivalent, except as indicated (Type SF 2.200, **SGI-250° C)
WIRING CHART (wire: Type Awg 150o C or equivalent (Type SF2‑200, SgI‑250o C))**
Color | Length | From | To |
---|---|---|---|
Yellow | 18″ (406mm) | High Limit | Ignition Control Temp. Terminal |
Yellow | 18″ (406mm) | High Limit | Ignition Control Temp Terminal |
Model #170FAV (WITHOUT THERMOSTAT) PARTS LIST
REF. #| ITEM #| DESCRIPTION| QTY.| REF. #| **ITEM
DESCRIPTION| QTY.**
---|---|---|---|---|---|---
1| 21898| Motor Support Ring| 1| 30 21907| Bracket, ThermoValve Mt.| 1
2| 22252| Grill, Inlet/Motor Mounting| 1| 31 23045| Bracket,
Ignition/Relay| 1
3| 21899| Support, Motor Stablizer| 1| 32 26079| Spacer, Standoff| 4
4| 22251| Motor| 1| 35 23276| Ignition/Relay Module| 1
5| 26074| Fan| 1| 36 26134| Compression Block, Relay| 1
6| 26655| Thermocouple, 10” w/JB| 1| 37 26656| Thermocouple, Connector|
1
7| 23036| Bracket, Thermocouple| 1| 38 21908| Control Box Assembly| 1
8| 21900| Nut, Thermocouple| 1| 39 26223| Strain Relief Bushing| 1
9| 23038| Nut, Orifice| 1| 40 21036| Power Cord Assembly| 1
10| 26168| High Limit Switch| 2| 41 21912| Cover, Cup, Valve| 1
1| 21901| Bracket, High Limit Switch| 1| 42 25026| Knob, Elevation| 1
12| 21 46| Flame Holder Assembly| 1| 43 22274| Plate, Elevation| 1
13| 21902| Orifice Assembly| 1| 44 21909| Nut, Elev. Plate Retaining| 2
14| 22249| Middle Cyl. Assembly| 1| 45 22273| Base, Control Box| 1
15| 22272| Outer Shell TS| 1| 26375| Label, Elevation Adjust.| 1
16| 28074| Clips, Handle Mounting| 2| 28769| Label, Safety
Precautions| 1
17| 28075| Handle, Plastic| 1| 28755| Label, General Hazard
Warning| 1
20| 23037| Nut, Spark Plug| 1| 28733| Label, Model| 1
21| 28774| Spark Plug/Flame Sensor| 1| 28784| Label, Operating
Inst.| 1
22| 21903| Flame Tube Assembly| 1| 27704| Label, Warning
Massachusetts| 1
23| 28776| Elbow, Flame Tube| 1| 26374| Label, Electrical
Grounding| 1
24| 25027| Knob, Variable Rate| 1| 21910| Label, Wiring Diagram| 1
25| 28777| Valve, Variable Rate| 1| 28203| Label, Hang Tag| 1
26| 21905| Ftg. Connector| 1| 26373| Label, Fan Rotation| 1
27| 27285| Valve, Thermoelectric| 1| 27709| Label, Fuel Button| 1
28| 26127| Ftg. Male Connector| 1| 70176| Manual, Operating Inst.|
1
29| 21906| Nut, TE Valve Retainer| 1| * 26225| Snap Bushings, 5/8”|
2
WARNING:
USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE
INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY
AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY.
PARTS ORDERING INFORMATION:
PURCHASING: Accessories may be purchased at any Mr. Heater local dealer or direct from the factory
FOR INFORMATION REGARDING SERVICE
Please call Toll-Free 800-251-0001 www.mrheater.com
Our office hours are 8:30 AM – 5:00 PM, EST, Monday through Friday.
Please include the model number, date of purchase, and description of problem in all communication.
LIMITED WARRANTY
Mr. Heater, Inc. warrants its heaters and accessories to be free from defects in material and workmanship for a period of 1 year from date of purchase. Mr. Heater, Inc. will repair or replace this product free of charge if it has been proven to be defective within the 1-year period, and is returned at customer expense with proof of purchase to Mr. Heater, Inc. within the warranty period.
Mr. Heater, Inc. reserves the right to make changes at any time, without notice or obligation, in colors, specifications, accessories, materials and models.
ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 •
216-881-5500
Mr. Heater is a registered trademarks of Enerco Group, Inc. © 2009, Enerco
Group, Inc. All rights reserved
ANSI Z83.7/CGA 2.14-2000
Operating Instructions and Owner’s Manual Enerco Group, Inc. | Force-Air Propane Construction Heater
Read User Manual Online (PDF format)