Oase 20000, 30000 AquaMax Eco Twin Instruction Manual

June 3, 2024
Oase

Oase 20000, 30000 AquaMax Eco Twin Instruction Manual
Oase 20000, 30000 AquaMax Eco Twin

Original manual. This manual belongs with the unit and must always be passed on together with the unit.

WARNING

  • Disconnect all electrical devices in the water from the power supply before reaching into the water. Otherwise there is a risk of severe injuries or death by electrocution.
  • This unit can be used by children aged 8 and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they understand the hazards involved. Do not allow children to play with the unit. Only allow children to carry out cleaning and user maintenance under supervision.

Further instructions in a PDF format are available for download online at:
www.oase.com/manual
QR code

The following additional topics are addressed in the operating manual:

  • Product features, symbols on the unit
  • Cleaning and maintenance, storage/winter-proofing, malfunction repair
  • Technical data, wear parts, spare parts, disposal

Safety information

Electrical connection
  • Special regulations apply for electrical installation in outdoor spaces. Only a qualified electrician may perform the electrical installation.
    • The qualified electrician has the necessary professional training, knowledge and experience to perform electrical installation in outdoor spaces. The electrician can detect potential dangers and knows how to adhere to regional and national standards, regulations and directives.
    • For your own safety, please consult a qualified electrician.
  • Only connect the unit if the electrical data of the unit and the power supply match.
  • Only plug the unit into a correctly installed outlet. Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
  • Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).
  • Protect open plugs and sockets from moisture.
Safe operation
  • Do not use the unit, if electrical lines or the housing are damaged.
  • Dispose of the unit if its power connection cable is damaged. The power connection cable cannot be replaced.
  • The impeller unit in the pump contains a magnet with a strong magnetic field that may affect the operation of pacemakers or implantable cardioverter defibrillators (ICDs). Keep a distance of at least 0.2 m between the implant and the magnet.
  • Do not carry or pull the unit by its power cable.
  • Route lines in such a way that they are protected from damage and do not present a tripping hazard.
  • Never carry out technical changes to the unit.
  • Only carry out work on the unit that is described in this manual.
  • Only use original spare parts and accessories.
  • Should problems occur, please contact the authorised customer service or OASE.

Intended use

Only use the product described in this manual as follows:

  • For pumping normal pond water for filter systems, waterfall systems and water course systems.

  • While adhering to the technical specifications.

  • Adherence to the permissible water quality.
    The following restrictions apply to the unit:

  • Do not use in swimming ponds.

  • Never use the unit with fluids other than water.

  • Never run the unit without water.

  • Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.

  • Do not connect to the domestic water supply.

  • Do not use for commercial or industrial purposes.

  • According to EMC (Electromagnetic Compatibility), this is a class A unit. The unit may cause malfunctions in living environments. It is the user’s responsibility to take suitable countermeasures.

Product Description

Overview

Product Description

1| Inlet 1 (suction side)

  • Connection of a satellite filter or skimmer.
  • Water flow through pump 1.

---|---
2| Inlet 2 (suction side)

  • Filter housing
  • Water flow through …
  • pump 1 or 2 or
  • pump 1 and 2.

3| Outlet (pressure side)

  • Connection of the return line into the pond (e.g. via a water course).

4| Receiver for controlling the pumps via the hand-held transmitter.
5| Ground stake for installing the receiver.
6| Hand-held transmitter for controlling the pumps.
7| Hose sleeve for outlet (recommendation).
8| Stepped hose adapter for inlet 1 and outlet (alternative).
9| Adapter for inlet 1.
10| Hose clips for fastening hoses on the hose sleeves.

Installation variants

A
Installation variants

  • Variant (a): Water flow only through the filter housing.
    •   * Pump 1 and 2 either operate in parallel or separately.
  • Variant (b): Water flow through the filter housing and through an additional satellite filter or skimmer.
  • Water flows through a satellite filter or a skimmer on inlet 1 to pump 1.
  • Water flows through the filter housing (inlet 2) to pump 2.

Installation and connection

The use of the pump is only permitted with observance of the specified water quality.

  • Pool water or salt water can impair the appearance of the unit. Such impairments are excluded from the guarantee.

WARNING
Severe injuries or death due to operation of this unit in a swimming pond. Defective electrical components will electrify the water with dangerous electrical voltage.

  • Never operate the unit in a swimming pond.

CAUTION
Rotating components in the intake and pressure socket area. Risk of injury when reaching into the sockets.

In particular, observe the following: A unit that has stopped due to overload can start up unexpectedly!

  • Do not reach into the opening of the intake socket or pressure socket while the power plug is plugged in.
  • If the sockets are freely accessible during operation, e.g. if no hoses are connected, use a hand guard to secure the sockets. The hand guard is available as an accessory.

NOTE
If the pump is used for conveying excessively soiled water, the impeller unit will be subject to increased wear and  will require earlier replacement.

  • Thoroughly clean the pond or pool before installing the pump.
  • Install the pump at a raised level above the bottom of the pond. This reduces intake of muddy water.

 Avoid direct sunlight on unit components that are not submerged, as they may overheat. If necessary, use a protective cover.

Connect the unit

Connect the pump according to the desired installation variant. (→ Installation variants)
Do not plug the power plug into the socket yet!

Water flow only through the filter housing

B
Connect the unit

Water flow through the filter housing and through a satellite filter or skimmer
C
Connection instruction

Installing the unit

D
Installing the unit

  • Place the pump horizontally on a stable, mud-free surface.

  • Ensure secure and stable positioning of the pump.

  • Only operate the pump when it is fully submerged.
     The pull rope allows you to simply pull the pump from the water.

    • Fasten the pull rope on the bottom filter casing through the round openings and make a knot.
Install the receiver

NOTE
The receiver will be damaged if it is constantly subjected to moisture.

  • Install the receiver in a moisture-protected location.
  • If necessary, use a protective cover.

E
Install the receiver

  • Position the receiver in a flood-protected location at least 2 m from the edge of the pond.
  • Fasten it to the ground with the ground stake or suspend it vertically using 2 screws.
    • Do not operate the receiver while it is in a horizontal position, only operate it in a vertical position with the ground stake intake pointing down.

Do not plug the power plug into the socket yet!

Commissioning/start-up

NOTE
The unit will be destroyed if it is operated with a dimmer. It contains sensitive electrical components.

  • Do not connect the unit to a dimmable power supply.

NOTE
Prevent the pump from running dry. Otherwise the pump will be destroyed.

  • Only operate the pump when it is submerged or flooded.
Switching ON/OFF
  • Switching on: Plug the power plug into the outlet.
    • The unit switches on immediately.
  • Switching off: Pull the power plug from the outlet.
Environmental Function Control (EFC)

When started up, the pump automatically performs a pre-programmed self-test (Environmental Function Control (EFC)). The pump detects if it is running dry / blocked or submerged. The pump shuts down automatically after 60 to 120 seconds if it runs dry/is blocked. In the event of a malfunction, disconnect the power supply and “flood the pump” or remove the obstacle. Afterwards, the unit can be restarted.

Operating functions

The hand-held transmitter allows you to switch pumps on and off remotely and to adjust their power.

  • Provided there is a line of sight between transmitter and receiver, radio transmission of up to 80 metres is possible.
  • Before it is possible to operate the unit with a transmitter, it is necessary to register (log in) the transmitter on the receiver. You can register up to 10 transmitters on the receiver.
    Operating functions

Functions of the hand-held transmitter

a| Digital display

  • The display shows the power level set for the two pumps. (0 … 100 %)

---|---
b| Buttons with the following functions:

  • Register (log in) the transmitter on the receiver:
  • Press button “b” on the receiver for approx. 1 s.
  • Press button “d0” on the transmitter for at least 3 s.
  • Save user-specific setting: See buttons “f”
  • Delete all transmitters in the receiver: Press button “b” on the receiver for at least 5 s.

c| Function monitoring LED

  • The LED lights up when a button is pressed on the transmitter.

d| ON/OFF button, pump 1
e| ON/OFF button, pump 2
f| Button for user-specific settings.

  • Factory setting:
  • f0: Pump power for both pumps = 25 %
  • f1: Pump power for both pumps = 75 %
  • Program user-specific setting:
  • Use the buttons “d”, “e” and “g” to set the condition you wish to call with button f0 or f1.
  • Press button “b” on the receiver for approx. 1 second.
  • Press button f0 or f1 on the transmitter.

g| Dimmer

  • Set pump power for both pumps. (0 … 100 %)

Support

OASE GmbH

Tecklenburger Straße 161
48477 Hörstel | Germany +49
 5454 80-0 +49
 5454 80-9353
[email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Oase User Manuals

Related Manuals