Danfoss 077Z7 Service Thermostats Installation Guide

October 27, 2023
Danfoss

077Z7 Service Thermostats
Installation GuideDanfoss 077Z7 Service Thermostats

077Z7 Service Thermostats

Installation Guide
Service thermostats
Type 077Z7
Service thermostats 077Z7010 Service thermostats 077Z7011 Length of capillary (in): L = 84
Min. sensor length mounted on evaporator (in): LS = 6
(Used as airsensor min. 2 x LS)
Service thermostats 077Z7012 Danfoss 077Z7 Service Thermostats fig
4Length of capillary (in): L = 42
Min. sensor length mounted on evaporator (in): LS = 4
(Used as airsensor min. 2 x LS)
Service thermostats 077Z7013
Danfoss 077Z7 Service Thermostats fig 3
Length of capillary (in): L = 84
Min. sensor length mounted on evaporator (in): LS = 6
(Used as airsensor min. 2 x LS)
Service thermostats 077Z7014
Danfoss 077Z7 Service Thermostats fig
5

Length of capillary (in): L = 84
Min. sensor length mounted on evaporator (in): LS = 5
(Used as airsensor min. 2 x LS)
Service thermostats 077Z7015
Danfoss 077Z7 Service Thermostats fig 6

Length of capillary (in): L = 42
Min. sensor length mounted on evaporator (in): LS = 4
(Used as airsensor min. 2 x LS)
Service thermostats 077Z7016 Danfoss 077Z7 Service Thermostats fig
7

Length of capillary (in): L = 84
Min. sensor length mounted on evaporator (in): LS = 5
(Used as airsensor min. 2 x LS)
Service thermostats 077Z7017 Danfoss 077Z7 Service Thermostats fig
8

Length of capillary (in): L = 66
Min. sensor length mounted on evaporator (in): LS = 4
(Used as airsensor min. 2 x LS)
The 077Z….EBD, 077Z….L EBD can be applied on systems with R290 and R600a as the working fluid.
Always adhere to local codes and safety guidelines. For countries with no conformity certification (UL, CE, CCC, CSA, EAC, etc.)
requirements on new systems, Danfoss recommends third party apporval for systems containing flammable refrigerants.
Note: All temperatures at 760 mm Hg

Danfoss A/S
Climate Solutions
danfoss.com
+45 7488 2222
Any information, including, but not limited to information on selection of product, its application or use, product design, weight, dimensions, capacity or any other technical data in product manuals, catalogues descriptions, advertisements, etc. and whether made available in writing, orally, electronically, online or via download, shall be considered informative, and is only binding if and to the extent, explicit reference is made in a quotation or order confirmation. Danfoss cannot accept any responsibility for possible errors in catalogues, brochures, videos and other material.
Danfoss reserves the right to alter its products without notice. This also applies to products ordered but not delivered provided that such alterations can be made without changes to form, fit or function of the product.
All trademarks in this material are property of Danfoss A/S or Danfoss group companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/S. All rights reserved.

© Danfoss
Climate Solutions | 2022.10
AN216286431722en-000103 | 2

Documents / Resources

| Danfoss 077Z7 Service Thermostats [pdf] Installation Guide
077Z7 Service Thermostats, 077Z7, 077Z7 Thermostats, Service Thermostats, Thermostats
---|---
| Danfoss 077Z7 Service Thermostats [pdf] Installation Guide
077Z7 Service Thermostats, 077Z7, Service Thermostats, Thermostats

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals