Oase AquaMax Eco Premium Instruction Manual

June 3, 2024
Oase

Oase AquaMax Eco Premium

Original manual. This manual belongs with the unit and must always be passed on together with the unit.

WARNING

  • Disconnect all electrical devices in the water from the power supply before reaching into the water. Otherwise there is a risk of severe injuries or death by electrocution.
  • This unit can be used by children aged 8 and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they understand the hazards involved. Do not allow children to play with the unit. Only allow children to carry out cleaning and user maintenance under supervision.

Further instructions in a PDF format are available for download online at: www.oase.com/manual

The following additional topics are addressed in the operating manual:

  • Product features, symbols on the unit
  • Dry installation of the pump
  • Cleaning and maintenance, storage/winter-proofing, malfunction repair
  • Technical data, wear parts, spare parts, disposal

Safety information

Electrical connection

  • Special regulations apply for electrical installation in outdoor spaces. Only a qualified electri-cian may perform the electrical installation.
    • The qualified electrician has the necessary professional training, knowledge and experience to perform electrical installation in outdoor spaces. The electrician can detect potential dangers and knows how to adhere to regional and national standards, regulations and direc-tives.
    • For your own safety, please consult a qualified electrician.
  • Only connect the unit if the electrical data of the unit and the power supply match.
  • Only plug the unit into a correctly installed outlet. Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
  • Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).
  • Protect open plugs and sockets from moisture.

Safe operation

  • Do not use the unit, if electrical lines or the housing are damaged.
  • Dispose of the unit if its power connection cable is damaged. The power connection cable can-not be replaced.
  • The impeller unit in the pump contains a magnet with a strong magnetic field that may affect the operation of pacemakers or implantable cardioverter defibrillators (ICDs). Keep a distance of at least 0.2 m between the implant and the magnet.
  • Do not carry or pull the unit by its power cable.
  • Route lines in such a way that they are protected from damage and do not present a tripping hazard.
  • Never carry out technical changes to the unit.
  • Only carry out work on the unit that is described in this manual.
  • Only use original spare parts and accessories.
  • Should problems occur, please contact the authorised customer service or OASE.
Intended use

Only use the product described in this manual as follows:

  • For pumping normal pond water for filter systems, waterfall systems and water course sys-tems.
  • While adhering to the technical specifications.
  • Adherence to the permissible water quality.

The following restrictions apply to the unit:

  • Do not use in swimming ponds.
  • Never use the unit with fluids other than water.
  • Never run the unit without water.
  • Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
  • Do not connect to the domestic water supply.
  • Do not use for commercial or industrial purposes.
  • According to EMC (Electromagnetic Compatibility), this is a class A unit. The unit may cause malfunctions in living environments. It is the user’s responsibility to take suitable counter-measures.

Product Description

Overview

Oase AquaMax Eco Premium-4

1| Inlet 1 (suction side)

·Filter housing

---|---
2| Inlet 2 (suction side)

· Connection of a satellite filter or skimmer.

· The flow rate at inlet 2 and with it the flow ratio of inlet 1 to inlet 2 is adjustable. To do so, re- lease the locking mechanism and push the connection to one of the following positions:

– Position 0: Inlet 2 is closed, water flow only via inlet 1.

– Position 1/2/3: Inlet 2 is open by approx. 25/50/75 %; meaning water flow via inlet 1 and 2 ac- cording to set intake ratio.

– Position 4: Inlet 1 is closed, water flow only via inlet 2.

3| Outlet (pressure side)

·    Connection of the return line into the pond (e.g. via a water course).

4| Power cable
5| Hose sleeve for outlet (recommendation).
6| Stepped hose adapter for inlet 2 and outlet (alternative).
7| Cover cap for closing inlet 2 when it is not in use.
8| Hose clips for fastening hoses on the hose sleeves.
9| Rubber feet for pump holder for dry installation.

Installation variants

  • Variant (a): Water flow only via the filter housing (inlet 1).
    • Set inlet 2 to position “0”.
    • Close inlet 2 using the cover cap.
  • Variant (b): Water flow via the filter housing (inlet 1) and additionally via a satellite filter or a skimmer on inlet 2.
    • Set inlet 2 to position “1”, “2” or “3”, depending on the desired flow ratio (25/50/75 %).
  • Variant (c): Water flow only via a satellite filter or a skimmer on inlet 2.
    • Set inlet 2 to position “4”.
  • Variant (d): Dry pump installation.
    • This variant requires the pump to be installed without a filter housing.
    • The pump is installed outside of the pond but lower than the water level.

Oase AquaMax Eco Premium-1

Seasonal Flow Control (SFC)
Nur AquaMax Eco Premium 12000, 16000 und 20000

Oase AquaMax Eco Premium-5

With the SFC function activated, the pump automatically optimises and reduces the amount of water and the delivery head by up to 50%. Thanks to the SFC function the pump adapts to the individual pond ecology throughout the year and supports the pond biology through tempera-ture-dependent circulation (winter mode, transition mode and summer mode).

The SFC function is switched on and off at the pump. The SFC function reduces the power consumption of the pump; without SFC, the pump permanently operates at maximum throughput. The seasonal flow control does not function when the pump is installed on land (dry installation). If a skimmer, satellite filter or Oase InScenio control unit is used, we recommend deactivating the SFC depending on the unit.

Installation and connection

The pump can be installed submerged (in water) or dry (outside the water).
The use of the pump is only permitted with observance of the specified water quality.

WARNING
Severe injuries or death due to operation of this unit in a swimming pond. Defective electrical components will electrify the water with dangerous electrical voltage.

  • Never operate the unit in a swimming pond.

CAUTION
Rotating components in the intake and pressure socket area. Risk of injury when reaching into the sockets.
In particular, observe the following: A unit that has stopped due to overload can start up unexpectedly!

  • Do not reach into the opening of the intake socket or pressure socket while the power plug is plugged in.
  • If the sockets are freely accessible during operation, e.g. if no hoses are connected, use a hand guard to secure the sockets. The hand guard is available as an accessory.

NOTE
If the pump is used for conveying excessively soiled water, the impeller unit will be subject to increased wear and will require earlier replacement.

  • Thoroughly clean the pond or pool before installing the pump.
  • Install the pump at a raised level above the bottom of the pond. This reduces intake of muddy water.

Avoid direct sunlight on unit components that are not submerged, as they may overheat. If necessary, use a protective cover.

Submerged installation of the pump

Connecting
Connect the pump according to the desired installation variant.
B Do not plug the power plug into the socket yet!

Oase AquaMax Eco Premium-2

Installation

Oase AquaMax Eco Premium-3

  • Place the pump horizontally on a stable, mud-free surface.
  • Ensure secure and stable positioning of the pump.
  • Only operate the pump when it is fully submerged.

The pull rope allows you to simply pull the pump from the water.

  • Fasten the pull rope on the bottom filter casing through the round openings and make a knot.

Commissioning/start-up

NOTE
Prevent the pump from running dry. Otherwise the pump will be destroyed.

  • Only operate the pump when it is submerged or flooded.
    Switching ON/OFF

  • Switching on: Plug the power plug into the outlet.

    • The unit switches on immediately.
  • Switching off: Pull the power plug from the outlet.

Environmental Function Control (EFC)
When started up, the pump automatically performs a pre-programmed self-test (Environmental Function Control (EFC)). The pump detects if it is running dry / blocked or submerged. The pump shuts down automatically after 60 to 120 seconds if it runs dry/is blocked. In the event of a mal-function, disconnect the power supply and “flood the pump” or remove the obstacle. Afterwards, the unit can be restarted.

OASE GmbH
Tecklenburger Straße 161
48477 Hörstel Germany
+49 (0) 5454 80-0 +49 (0) 5454 80-9353
[email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Oase User Manuals