lEDYi Lighting LOC-ELHB MW MCCT Series LED Ceiling Light Installation Guide
- June 5, 2024
- LEDYI Lighting
Table of Contents
- lEDYi Lighting LOC-ELHB MW MCCT Series LED Ceiling Light
- SAFETY INSTRUCTIONS: Read instructions carefully before attempting to
- CAUTION: Risk of fire
- CLEANING & MAINTENANCE
- TROUBLESHOOT
- 0-10V DIMMABLE WIRING
- MOUNTING
- WATTAGE AND CCT ADJUSTABLE TABLE SWITCH SETTING
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
lEDYi Lighting LOC-ELHB MW MCCT Series LED Ceiling Light
SAFETY INSTRUCTIONS: Read instructions carefully before attempting to
install fixture
- All wiring should be performed by a qualified electrician.
- Disconnect power before installing or servicing. This fixture must be wired in accordance with the National Electrical Code and applicable local codes and ordinances.
- Proper grounding is required to ensure personal safety.
CAUTION: Risk of fire
- WARNING : Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
- WARNING : Fixture must be connected to a wiring system with an equipment-grounding conductor.
- WARNING : Make sure the supply voltage is the same as the rated luminaire voltage.
- WARNING : Do NOT operate in ambient temperatures above those indicated in the fixture label.
- WARNING : Avoid use in environments containing sulfur, chlorine or other halides, methyl acetate or ethyl acetate, cyanoacrylates, glycol ethers, formaldehyde, or butadiene.
CLEANING & MAINTENANCE
CAUTION : Be sure the fixture temperature is cool enough to touch. Do NOT clean or maintain while the fixture is energized.
- Clean glass lens with non-abrasive cleaning solution.
- Do NOT open fixture to clean the LED. Do NOT touch the LED.
Note : These instructions do not cover all details or variation in equipment, nor do they provide for every possible situation during installation, operation or maintenance.
TROUBLESHOOT
- If the light will not come on:
- A. Light switch is turned off. Turn light switch on.
- B. Fuse is blown, or circuit breaker is turned off. Replace fuse or turn circuit breaker on.
- C. Incorrect circuit wiring. Verify that fixture is wired properly.
0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 100V through 277V, 50/60Hz. A 5-wire cord is provided. For 0-10V dimming, follow the wiring instructions in diagram picture.
- Connect the BLACK fixture lead to the (+) LINE supply lead.
- Connect the WHITE fixture lead to the (-) COMMON supply lead.
- Connect the GROUND wire from fixture to supply ground. Do NOT connect the GROUND of the dimming fixture to the output.
- Connect the PURPLE fixture lead to the (V+) DIM lead.
- Connect the GRAY fixture lead to the (V-) DIM lead.
- Cap the YELLOW fixture lead, if present. Do NOT connect.
MOUNTING
HOOK MOUNTING :
- Fix the hook on the light. (Clockwise rotation)
- Use an electric drill to bore a hole in the wall.
- Install the hanger to the wall.
- Fix the hook onto the hanger and complete installation.
U-BRACKET MOUNTING :
- Use an electric drill to bore 2 holes in the wall.
- Set the expansion screws to the existing drilling holes.
- Install the bracket to the wall.
- Use a wrench to reverse hexagon nut adjust the requested angle.
WATTAGE AND CCT ADJUSTABLE TABLE SWITCH SETTING
(Only for models with wattage and CCT adjustable functions.)
- Default Wattage: 150W
- Default CCT: 5,000K
LOC-ELHB-MW(80/100/150)MCCT(30/40/50)-LV
Wattage Options CCT Options
- 80W
- 3,000K
- 100W
- 4,000K
- 150W
- 5,000K
Phone: (844) LEDONE6 | Fax: 1-510-217-9461 | Web: www.ledonecorp.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>