Oase AquaMax Eco Titanium Pump Instruction Manual
- June 3, 2024
- Oase
Table of Contents
AquaMax Eco Titanium Pump
AquaMax Eco Titanium
31000, 51000, 81000
Commissioning
Original manual. This manual belongs with the unit and must always be passed on together with
WARNING
- Disconnect all electrical devices in the water from the power supply before reaching the water. Otherwise, there is a risk of severe injuries or death by electrocution.
- This unit can be used by children aged 8 and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they understand the hazards involved. Do not allow children to play with the unit. Only allow children to carry out cleaning and user maintenance under supervision.
Further instructions in a PDF format are available for download online at: www.oase.com/manual
The following additional topics are addressed in the operating manual:
- Product features, symbols on the unit
- Turning the pump casing
- Integration into the EGC network
- Cleaning and maintenance, storage/winter-proofing, malfunction repair
- Technical data, wear parts, spare parts, disposal
- Characteristic curves of the pump
Safety information
Electrical connection
-
Special regulations apply for electrical installation in outdoor spaces. Only a qualified electrician may perform the electrical installation.
– The qualified electrician has the necessary professional training, knowledge, and experience to perform electrical installation in outdoor spaces. The electrician can detect potential dangers and knows how to adhere to regional and national standards, regulations, and directives.
– For your own safety, please consult a qualified electrician. -
Only connect the unit if the electrical data of the unit and the power supply match.
-
Only plug the unit into a correctly installed outlet. Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
-
Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).
-
Protect open plugs and sockets from moisture.
Safe operation
- Do not use the unit, if electrical lines or the housing are damaged.
- Dispose of the unit if its power connection cable is damaged. The power connection cable cannot be replaced.
- The impeller unit in the pump contains a magnet with a strong magnetic field that may affect the operation of pacemakers or implantable cardioverter defibrillators (ICDs). Keep a distance of at least 0.2 m between the implant and the magnet.
- Do not carry or pull the unit by its power cable.
- Route lines in such a way that they are protected from damage and do not present a tripping hazard.
- Never carry out technical changes to the unit.
- Only carry out work on the unit that is described in this manual.
- Only use original spare parts and accessories.
- Should problems occur, please contact the authorised customer service or OASE.
Intended use
Only use the product described in this manual as follows:
- For pumping normal pond water for filter systems, waterfall systems, and watercourse systems.
- While adhering to the technical specifications.
- Adherence to permissible water quality.
The following restrictions apply to the unit:
- Do not use in swimming ponds.
- Never use the unit with fluids other than water.
- Never run the unit without water.
- Do not use in conjunction with chemicals, foodstuff, or easily flammable or explosive substances.
- Do not connect to the domestic water supply.
- Do not use it for commercial or industrial purposes.
- According to EMC (Electromagnetic Compatibility), this is a class A unit. The unit may cause malfunctions in living environments. It is the user’s responsibility to take suitable countermeasures.
Product Description Overview
A | AquaMax Eco Titanium | |||
---|---|---|---|---|
31000 | 51000 | 81000 | Description | |
1 | • | • | • | Pump casing |
The pump casing can be turned by 90°.
2| •| •| •| Stand
Ensures a stable position. Screwing the stand to the ground is possible.
3| •| •| •| Outlet Keep the protective caps.
(pressure socket) To prevent serious injury while the pump is
4| •| •| •| Inlet running, immediately attach the protective
(suction socket) cap after you have removed a connected
pipe.
5| •| –| –| Clip attachment for fastening the OASE Eco Control.
6| •| –| –| Rubber element for the clip attachment
7| –| –| •| Rubber foot
Removable if the stand is to be screwed to the ground.
8| •| •| •| Control system connection
•The control unit OASE Eco Control (accessories) is required to operate the
pump.
•Alternatively, the pump can be integrated in an OASE Control network.
•For information on OASE Control, visit www.oase.com.
Seasonal Flow Control (SFC)
Activating the SFC function reduces energy costs as the unit automatically
optimizes its speed and with it the water volume and pumping head based on the
water temperature. However, this also means that the SFC function causes the
unit to adapt to the individual pond ecology throughout the year and support
the pond biology through temperature-dependent circulation (winter mode,
transition mode, and summer mode).
**** The SFC function does not work with dry pump installation. If a skimmer,
satellite filter, or OASE InScenio control unit is used, it may be advisable
to deactivate the SFC function, depending on the system.
Installation and connection
The pump can be installed submerged (in water) or dry (outside the water).
The use of the pump is only permitted with observance of the specified water
quality.
WARNING
Severe injuries or death due to the operation of this unit in a swimming pond.
Defective electrical components will electrify the water with dangerous
electrical voltage.
- Never operate the unit in a swimming pond.
NOTE
If the pump is used for conveying excessively soiled water, the impeller unit
will be subject to increased wear and will require earlier replacement.
- Thoroughly clean the pond or pool before installing the pump.
- Install the pump at a raised level above the bottom of the pond. This reduces intake of muddy water.
**** Avoid direct sunlight on unit components that are not submerged, as they may overheat. If necessary, use a protective cover.
Connecting the control system
The OASE Eco Control control unit (accessory) is required for operating the pump.
AMX0101
Alternatively, the pump can be integrated in an OASE Control network. For
information on this topic, visit www.oase.com.
** For
further information, refer to the operating manual for the accessories.
Connecting and disconnecting the OASE Control plug connection**
NOTE
The unit will be damaged, if water enters the plug connector.
• Connect the plug connector or place the protective cap on the plug
connector.
– Ensure that the rubber seal is clean and fits exactly. If the rubber seal is
damaged, it must be replaced.
– Secure the plug connector or the protective cap with the two screws.
Submerged installation of the pump
B
-
Ensure that the power cables and mains sockets are at least 2 m from the water.
-
For installation of the pump in a pump chamber (recommended):
– For a swimming pond or pool frequented by swimming people, install the pump chamber at least 2 m from the water.
– Install the pump horizontally.
– Screw the stand to the floor of the pump chamber to ensure the stability of the pump. -
For installation of the pump without a pump chamber:
– Place the pump horizontally on a stable, mud-free surface.
– Ensure secure and stable positioning of the pump. -
Only operate the pump when it is fully submerged.
-
Pool water or salt water can impair the appearance of the unit. Such impairments are excluded from the guarantee.
Dry installation of the pump
C
-
Ensure that the power cables and mains sockets are at least 2 m from the water.
-
For a swimming pond or pool frequented by swimming people, install the pump at least 2 m
from the water. -
Place the pump horizontally on a stable surface.
-
Ensure secure and stable positioning of the pump. If necessary, screw the stand to the ground.
-
Protect the pump from direct sunlight.
-
Adhere to the maximum permissible ambient temperature. If necessary, provide forced cooling.
Connecting the pressure side/suction side
D, E
WARNING
The impeller unit rotates very fast. Do not reach into the openings of the
suction socket or pressure socket as there is a risk of severe injury such as
loss of limb.
- Secure the suction socket/pressure socket with a hand guard if no pipe is connected. The hand guard is available as an accessory (AquaMax Eco Titanium 31000: 48597, AquaMax Eco Titanium 51000, 81000: 73658).
- Place the pump in a pump chamber and secure access to the pump chamber (use a padlock or screws to secure the access point).
Commissioning/start-up
NOTE
The unit will be destroyed if it is operated with a dimmer. It contains
sensitive electrical components.
- Do not connect the unit to a dimmable power supply.
NOTE
Prevent the pump from running dry. Otherwise, the pump will be destroyed.
- Only operate the pump when it is submerged or flooded.
Switching ON/OFF
-
Switching on: Plug the power plug into the outlet.
– The unit switches on immediately. -
Switching off: Pull the power plug from the outlet.
Environmental Function Control (EFC)
When started up, the pump automatically performs a pre-programmed self-test
(Environmental Function Control (EFC)). The pump detects if it is running dry
/ blocked or submerged. The pump shuts down automatically after 60 to 120
seconds if it runs dry/is blocked. In the event of a malfunction, disconnect
the power supply and “flood the pump” or remove the obstacle. Afterwards, the
unit can be restarted.
OASE GmbH
Tecklenburger Straße 161
48477 Hörstel | Germany
+49 (0) 5454 80-0
+49 (0) 5454 80-9353
info@oase.com
84057/03-22
Documents / Resources
| Oase
AquaMax Eco Titanium
Pump
[pdf] Instruction Manual
31000, 51000, 81000, AquaMax Eco Titanium Pump, AquaMax, Eco Titanium Pump,
Eco Titanium, Pump, Eco Pump, Titanium Pump, Commissioning
---|---
References
Read User Manual Online (PDF format)