dantherm DR26 Mobile electric dehumidifiers User Manual
- June 5, 2024
- Dantherm
Table of Contents
DR26 Mobile electric dehumidifiers
User Manual
DR26 – DR44 – DR52 – DR80 – DR100
DR26 Mobile electric dehumidifiers
MODEL | DR 26 | DR 44 | DR 5 2 | DR 80 | DR 100 |
---|---|---|---|---|---|
30 ÷ 98 % | 30 ÷ 98 % | 30 ÷ 98 % | **30 ÷ 98 % | ||
30 ÷ 70 %** | **40 ÷ 98 % |
40 ÷ 70 %
| 1 ÷ 32 °C| 1 ÷ 32 °C| 1 ÷ 32 °C| 1 ÷ 32 °C
1 ÷ 45 °C| 3 ÷ 32 °C
3 ÷ 45 °C
| 350 m³/h| 480 m³/h| 480 m³/h| 1.000
m³/h| 1.000 m³/h
| 27 l-л / 24 h-ч| 41 l / 24 h| 52 l / 24 h| 80 l/ 24 h|
86 l / 24 h
| R1234YF| R1234YF| R1234YF| R1234YF| R1234YF
| ~ 220-240 V 50 Hz**
520 W / 2,8 A
| ~ 220-240 V 50 Hz
610 W / 3,1 A
| ~ 220-240 V 50 Hz
890 W / 4,4 A
| ~ 220-240 V 50 Hz
1.200 W / 6 A
| ~ 220-240 V 50 Hz
1.250 W / 6 A
dB (A)| 46 dB-дБ| 53 dB| 53 dB| 50 dB| 50 dB
| 8 l-л| 12 l-л| 12 l-л| 12 l-л| 12 l-л
| 30 kg| 43 kg| 47 kg| 66 kg| 69 kg
| 2,6 mPa
LRA 9 A| 2,6 mPa
LRA 16 A| 2,6 mPa
LRA 21,6 A| 2,6 mPa
LRA 20 A| 2,6 mPa
LRA 20 A
CO 2 Eq| 1,2| 1,5| 1,4| 2,8| 2,5
GWP| 4| 4| 4| 4| 4
IP| IP20| IP20| IP20| IP20| IP20
- 30°C – UR 80% – при температуре 30°С и относительной влажности воздуха 80%
IMPORTANT: In order to have a correct function you must use an electrical generator in class G3 or more (frequency variation ±1%, tension variation ±2%). The maximum power of the electrical generator must be three times the nominal power of the device that you must connect.
PICTURES
INDEX
1| INTRODUCTION
2| GENERAL DESCRIPTION OF THE UNIT
3| PRELIMINARY OPERATIONS
4| START-UP
5| MAINTENANCE
6| ALARM LIST
INTRODUCTION
►►1.1. INTRODUCTION
The manual is intended for the end user only in regard to operations that can
be performed with closed panels. The operations that require opening doors or
panels with tools must only be performed by expert personnel. Each appliance
must be connected to the power supply via a cable with a power plug supplied
with the unit. For maintenance operations, the power plug must always be
disconnected to allow the operator to intervene in safe conditions.
If assistance or spare parts are required, read the identification plate
located outside of the unit to identify the appliance (model and serial
number). lv et ro sk bg uk bs el zh
►►1.2. GENERAL SAFETY RULES
The purpose of the manual and of the entire documentation supplied is to allow
both the installer and operator to correctly perform the installation, start-
up, and maintenance of the equipment, without causing damage to the personnel
in charge and to the unit.
Each appliance is subject to a risk assessment carried out in compliance with
current legislation, which defines the necessary actions and implements the
protective measures required to achieve the risk reduction objectives. All
activities regarding the operation and maintenance of the unit must be
performed:
- Only by properly trained people, who must implement safe working practices and use the personal protective equipment appropriate to the specific task performed, based on their specific qualification.
- Only by properly trained people who have read and fully understood the manuals, technical documents, and safety documents.
- Use of the appliance must not be allowed to anyone who is not adequately trained and skilled.
This manual, the technical documents, and any security documents attached must
be read and stored for the entire lifespan of the appliance:
CAUTION: This appliance is designed for use in an indoor environment.
CAUTION: The unit must be connected to an electrical system that complies
with local electrical safety regulations.
CAUTION: The unit must be placed by following the dimensions and spaces
required, including the minimum spaces allowed by adjacent structures.
CAUTION: This equipment must always be connected to the earth. We decline
any liability for any danger or damage caused if this requirement is not
complied with.
CAUTION: Sharp tools (screwdrivers, needles, or the like) must not be
inserted into the grids or inside any other panel opening, especially when the
unit is open to remove the filter.
CAUTION: All maintenance and cleaning operations on the unit must be
performed with the power supply disconnected. Never remove the front grille or
open any part of the unit without first disconnecting the plug from the
socket.
CAUTION: Do not use water to clean the unit. Use a wet cloth to clean the
unit.
Never spray water on the unit and its electrical components.
The equipment must always be kept in a vertical position in order to prevent
accidental spillage of condensation (water) from the specific container. It is
strictly forbidden to move the equipment while connected to the power outlet,
as the resulting vibrations and movements may cause condensation to leak from
the specific container, thus affecting the electrical parts.
The unit can only be moved after emptying the condensate tank, and in any
case, it is ALWAYS REQUIRED to remove the plug from the socket before moving
the appliance. Should water be accidentally spilled on the appliance, the unit
must be immediately turned off and disconnected from the power supply, and may
only be turned on after eight hours have elapsed.
CAUTION: The equipment contains R1234yf refrigerant: this gas is
flammable. The amount of charge is indicated in the data table of this user
manual.
Warning, the refrigerant is odorless. Do not use any means to accelerate the
defrosting process or for cleaning other than those recommended by the
manufacturer.
The appliance must be placed in a room that does not have ignition sources
continuously in operation (e.g. open flames, a gas appliance while running or
an electric heater running).
Do not drill holes into or burn the appliance.
►►1.3. PERSONAL PROTECTIVE EQUIPMENT
Use the following personal protective equipment during unit use and
maintenance operations:
CLOTHING: Those who carry out maintenance or work on the unit in
environments with slippery floors must wear safety shoes with non-slip soles.
GLOVES: Appropriate gloves must be worn during cleaning and maintenance
operations. When refilling the refrigerant gas, the use of appropriate gloves
is mandatory in order to prevent the risk of freezing.
MASK AND GOGGLES: Masks to protect the respiratory tract and safety
goggles to protect the eyes must be worn during cleaning and maintenance
operations.
►►1.4. GENERAL SAFETY RULES
The following safety signs, which must be respected, are affixed to the unit:
** Read the user manual.
Read the technical manual.
Electric shock hazard.
Flammable material hazard.
CAUTION:** It is strictly forbidden to remove the safety signs on the
units.
GENERAL DESCRIPTION OF THE UNIT
(FIG. 1)
A dehumidifier is an appliance suitable for controlling the humidity of the
room it is placed in. Dehumidification is carried out via a refrigeration
cycle which is based on the physical principle whereby the air, when it comes
into contact with a cold surface, wets it, releasing humidity in the form of
condensation drops. The equipment is made up as follows (FIG. 2): Air is
extracted from the appliance: it passes through the washable filter (1), the
aluminum coil (evaporator) (2), the hot exchanger (condenser) (3), the fan (4)
and finally the dehumidified air flows out and is recirculated into the room
through the grille. The condensed water is collected in the tank (5). A
microswitch stops the appliance when water in the tank reaches a certain
level. An electronic board (6) manages the correct operation of the appliance.
This appliance is equipped with hot gas to defrost system, which ensures the
correct operation of the dehumidifier within the temperature and humidity
range specified in the technical data table.
►►2.1. REFRIGERANT CIRCUIT
The refrigerant gas used in these units is R1234yf. The refrigerant circuit is
built in compliance with current standards. Flammable material hazard. This
unit is hermetically sealed and contains fluorinated gas R1234yf GWP (R1234yf)
= 4.
PRELIMINARY OPERATIONS
►►3.1. REMOVAL OF THE PACKAGING AND ASSEMBLY
Remove the packaging taking care not to damage the unit. Dispose of the
packaging products (wood, plastic, cardboard), taking them to the specialized
collection or recycling centers (follow the local regulations in force).
CAUTION: Depending on the model, assemble the appliance, with any
handles, wheels, and all relevant hardware (FIG. 3) housed inside the
packaging before commissioning.
►►3.2. INSPECTION
All units are factory assembled and wired (except for certain components).
Upon receiving the unit, it must be immediately and thoroughly inspected,
checking that it has not been damaged during transport or that no parts are
missing.
Before use, specifically check for any dents on the external metal panels,
including those in the tank compartment. Also check that the cable, plug, and
relevant insulation are intact. Otherwise, it is FORBIDDEN to connect and
start the unit, which must be sent to an authorized service center.
►►3.3. OPERATING PRINCIPLES CAUTION:
To ensure the correct operation of the appliance, it is recommended to operate
the unit within the limits shown on the technical data table.
►►3.4. POSITIONING
Set up the appliance to ensure adequate airflow.
CAUTION: Make sure that the appliance is placed in such a way so as to
prevent contact with water.
►►3.5. SERVICE AREA
The hot air expelled by the fan must not be obstructed. Avoid hot air
recirculation between suction and delivery to prevent compromising the
performance of the unit or even interrupting normal operation.
CAUTION: The equipment must not be placed in cramped environments, which
do not allow adequate distribution of the air from the air outlet grille into
the room.
CAUTION: Do not place or hang objects on the front panel, it may cause
damage to the unit.
►►3.6. GENERAL INFORMATION
CAUTION: Disconnect the power plug from the socket before carrying out
any maintenance operation on the electrical part.
CAUTION: Check that the supply voltage corresponds to the unit’s
operating data (voltage and frequency) shown on the data plate on the
dehumidifier. The appliance is fitted with a power cable for correct
operation.
CAUTION: The earthing connection is mandatory.
START-UP
►►4.1. PRELIMINARY CHECKS
IMPORTANT: For dual voltage mod- els (…DV), check the position of the
transformer switch (220-240V / 110-120V). If the set voltage does not match
that supplied by the mains, the voltage must be adapted (FIG. 4). Loosen the
two lid screw fasteners, shift/press the switch onto the voltage value
supplied, and mount the lid again.
CAUTION: Check that the power cord is properly connected.
CAUTION: Check that all the cover panels are in the correct position and
are locked via fixing screws before commissioning.
CAUTION: Always disconnect the power supply if the appliance is not used
for a long period of time.
►►4.2. CONTROL PANEL
(FIG. 5)
The units are equipped with a luminous signaling panel that indicates their
operating status. A brief description of their meaning is provided below.
CONTROL PANEL:
LED:
►POWER LED: This LED is on if the unit is in the “ON” status, but in standby
mode (i.e. the compressor is off).
►ALARM LED: This LED is on when the unit is in alarm. The display will show
the error message.
►WORKING LED: This LED is on when the compressor is running. The LED flashes
when the dehumidifier is waiting to restart or is in defrost mode. The LED
turns off when the desired amount of humidity has been reached in the “ON”
status.
►FULL LED: This LED is on when the condensate tank is full or if the pump is
in alarm. BUTTONS:
►ON/OFF: To turn on the dehumidifier, simply press the “ON/OFF” button. Based
on the relative humidity set, the appliance starts working. When the room
humidity reaches the required level, the appliance goes into standby mode and
the unit stops but remains in the “ON” status (POWER LED on). If the room
humidity rises again, exceeding the previous set point, the dehumidifier
restarts again. Press the “ON/OFF” button to turn off the appliance (with the
appliance off, the display continues to indicate the relative humidity in the
environment).
►“-” / “+” (HUMIDITY SET): Press the “-” / “+” buttons to set the relative
humidity desired. The display will start flashing, showing the new reference
set point. After a few seconds, the display stops flashing and the new
humidity set point has been detected by the electronics. It is possible to
operate the appliance regardless of the degree of humidity present in the
environment. By pressing the “-” button until the “CONT” message appears on
the display, the appliance will operate continuously.
►HOURS: Press the “HOURS” button to view the working hours of the appliance.
►►4.3. DISCHARGE PIPE CONNECTION (Set-up) (FIG. 6) A discharge pipe can be
connected to the appliance. A hose connection with a diameter of 16 mm is
fitted on the tank.
►►4.4. CONNECTION OF THE CONDENSATE PUMP (Optional)
Depending on the model, the appliance can be set up for the connection of the
condensate discharge pump. For a correct connection, disconnect the unit from
the power supply before carrying out any operation.
For a correct installation of the condensate pump, refer to the technical
manual included in the optional kit.
MAINTENANCE
►►5.1. CHECKS TO BE PERFORMED BY THE USER
(FIG. 7) The only maintenance to be carried out by the user is the cleaning of
the air filter, which must be performed at least once a month. The cleaning
frequency can be increased due to the dustiness of the working environment of
the appliance.
CAUTION: REMOVE THE FILTER FROM THE APPLIANCE TO PERFORM CLEANING. IT IS
FORBIDDEN TO PERFORM CLEANING WITH THE FILTER INSTALLED.
►►5.2. SPARE PARTS
Should it be required to replace one or more parts during maintenance by
specialized operators, this must be done by using original spare parts only.
If required, request the “spare parts list” from your vendor, specifying the
model and a serial number of the unit.
►►5.3. DISMANTLING THE UNIT
The unit has been designed and built to ensure continuous operation. The
lifespan of some components such as the fan and the compressor depends on
their maintenance. CAUTION: The unit contains substances and components
dangerous to the environment (electronic components, refrigerant gas, and
oils). At the end of its useful life, in the event of dismantling the unit,
the operation must be carried out by specialized refrigerating personnel. The
unit must be sent to specific specialized centers for the collection and
disposal of equipment containing dangerous substances. The refrigerant fluid
and the lubricating oil contained in the circuit must be recovered, in
accordance with the regulations in force in your country.
ALARM LIST
ALARM | POSSIBLE CAUSE | POSSIBLE SOLUTION |
---|---|---|
FULL + “FULL” | Tank full or missing | The alarm is reset automatically by |
emptying or inserting the tank
ALARM + “Lot”| Room temperature too low| Room temperature conditions are not
suitable for operation
ALARM + “Prob”| Humidity probe malfunction. In any case, the unit continues to
function| Contact the authorized assistance center
ALARM + “Pro3”| Room temperature probe malfunction.
The dehumidifier goes into stand-by mode| Contact the authorized assistance
center
ALARM + “def”| Defrost thermostat malfunction. The dehumidifier goes into
stand-by mode| Contact the authorized assistance centre
ELECTRIC SYSTEM
1. COMPRESSOR
2. MOTOR FAN
3. ELECTROVALVE
4. PLUG
5. ELECTRONIC BOARD
6. DISPLAY
7. TANK SENSOR
8. PUMP CONNECTOR| 9. AUTOTRANSFORMER
10. PUMP
11. VOLTAGE SELECTORBROWN
12. BLUE
13. BLACK
14. RED
15. GREY
16. ORANGE
---|---
► DISPOSAL OF THE PRODUCT
- This product has been designed and manufactured with top-quality materials and components, which can be re-cycled and re-used.
- When a crossed-wheely bin symbol is attached to the product, it means that the product is protected by the, 2012/19/UE European Directive.
- Please obtain information regarding the local differentiated collection system for electrical and electronic products.
- Respect local Standards in force and do not dispose of old products as normal domestic waste. Correct disposal of the product helps to prevent possible negative consequences for health, the environment, and mankind.
CE CONFORMITY CERTIFICATE
DANTHERM S.p.A. Via Gardesana 11, -37010- Pastrengo (VR), ITALY
Product
DR 26 DR 44 DR 52 DR 80 DR 100
We declare that it is compliant with:
2014/30/EU, 2014/35/EU, 2011/65/EU
EN 60335-1 (2012); AC (2014); A11 (2014)
EN 60335-2-40 (2003); A11 (2004); A12 (2005)
EN 55014-1 (2006); A1 (2009); A2 (2011)
EN 55014-2 (1997); AC (1997); A1 (2001); A2 (2008)
EN 50581 (2012)
EN 378-2 (2016)
IEC 60335-2-40 (2018)
Pastrengo, 2020
Stefano Verani (Member of the Board)
Dantherm S.p.A.
Via Gardesana 11, -37010- Pastrengo (VR), ITALY| Dantherm Sp. z o.o.
yn. Mara3mHosa, 5A, 62-023 ram,1-1011bWA
---|---
Dantherm Sp. z o.o.
ul. Magazynowa 5A, 62-023 Gqdki, POLAND| Dantherm SAS
23 in. EBreHHH XeHadxba — LIC 80010 69694 BEH14CbE, Ltegexc, OPAHLMFI
Dantherm SAS
23 rue Eugene Henaff – CS 80010 69694 VENISSIEUX, Cedex, FRANCE| 000
«gaiiTepm»
Yn. TpaHcnopcHae, 22/2, 142802, r. Ci-ynmo, Mocicoacicas o6n., PO
Dantherm LLC
ul. Transportnaya 22/2, 142802, STUPINO, Moscow region, RUSSIA| Dantherm
China LTD
IOHbHyaHb poag, 512, c-rpoeHme 2B, WaHxa0, 201906, K14TA171
Dantherm China LTD
Unit 2B, 512 Yunchuan Rd., Shanghai, 201906, CHINA| Dantherm SP S.A.
Poligono Industrial, 28108 L(/Kana6o3oc, 6 lionmroHol4Hgyc-rpman, 28108
Alcobendas, Madrid, SPAIN
Dantherm S.p.A.
Bma rapgecaHa 11, 37010 flacTpeHro (BepoHa),MTAJW1F1| Dantherm SP S.A.
C/Calabozos, 6AnKo6eHDac, Magpm-r,14CrIAH145=1
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>