Specification
Model | CL- 60D | CL- 120D |
---|---|---|
LED | 900pcs | 1800pcs |
Color Temperature | 2700K-6500K | |
Intensity | 0%-100% | |
llluminance | 2000 Lux@lm | 3700 Lux@lm |
Half beam angle | About65″ | |
Beam angle | About 100″ | |
Half beam angle (with honey comb) |
About40″
|
About45″
CRI| 95
TLCI| 99
Working Voltage| DC 11V-17V
Output power| Appr. 60W| Appr. 120W
Energy Efficiency Index|
Test under this parameter: Dimmer=100% ,CCT 6500k
Dimension| See Fig.I /Fig.2 /Fig.3
Luminous size| 310mm x 310mm| 600mm x 310mm
Weight| 3.2Kg| 4.7Kg
Cautions
- Do not disassemble the panel light or touch the interior with metal objects to avoid damage;
- Do not store the panel light in dusty or wet environment to avoid damage;
- USB interface is reserved interface, please use it according to the specified environment of the company’s related products, not for other purposes, so as not to cause loss;
- Do not connect the output device of the DMX signal in the panel light network when using the mutual control function of the panel light, otherwise the function can not be used normally;
- Only use the light in the temperature range of -l0
Maintenance
- Use soft dry cloth to clean the light and front panel. Can also Use a soft cloth dipped slightly in a neutral detergent solution for cleaning, but wipe with a soft dry cloth after cleaning.
- Do not use wet cloth, absolute alcohol, benzene to wipe the light panel or soft panel, otherwise will damage the soft panel.
Overall dimension
Appearance
- CD Barn door
- Diffuser
- Mounting hole
- DMXOUT
- USB interface
- DMXIN
- LCD screen
- Intensity
- Color temp
- DC input
- Power switch
- Adjust knob
- U-shaped bracket
- Ring
- Bracket Plate
- Bracket Adaptor
LCD display information
Take the “color temperature 5600 k, brightness 100% , battery full power supply, DMX communication mode, communication address 008” as an example:
- Current Support Communication Control Mode for Light – DMX Communication Mode
- Communication control mode currently supported by light- Inter control mode between lamps and lanterns
- Brightness display
- Communication address
- Color temperature
- Power supply display (Adaptor)
- Power supply display (Battery)
The power display when using battery:
Four cells | About 80%-100% |
---|---|
Three cells | About 60%-80% |
Two cells | About 40%-60% |
One cells | About 20%-40% |
Blank | Below 20%, Power warning |
Accessories
Fig.9~Fig.10 shown as how to assembly the honeycomb, CL-60D is the same as CL- 120D.
- M3*16 Screws
- Honeycomb
Usage
Install
-
Accessories
Honeycomb (fig.9, fig.10) installation method detailed see [Accessories] -
Install this product on the light bracket according to the requirement of use, adjust the illumination angle of light through adjustable handle.
Power supply
This product support battery and adaptor power supply, switch on the light
(Fig.6 ®) ,set the require light parameter by brightness adjusting knob(Fig.6
@),color temperature adjusting knob (Fig.6 ®), then use normally.
Tips: The connection and disconnection of power adaptor XLR.
-
Connection
Align the hump of output male XLR to the gap of the DC socket,connect XLR and DC socket,the adaptor will connect with the light when you hear the crack sound. -
Disconnection
Hold the hump of the DC output female XLR and pull out,the power adaptor and the light will be disconnected.
Setting and Use of Brightness and Color Temperature
This product support two color temperature and brightness adjusting mode: General adjusting mode, Fast adjusting mode. Press brightness/color temperature adjusting knob (Fig.6@/®) to change the adjusting mode the user can set the brightness/color temperature quickly by combining the two adjustment modes according to the usage demand.
General adjusting mode
-
Color temperature adjusting
Range:2700K-6500K, adjusting step length :SOK (2). -
Brightness adjusting
Range:0%-100%, adjusting step length: 1 %
Fast adjusting mode
- Color temperature adjusting In this mode, you can quickly select common color temperature: 2700K, 3200K, 4500K, 5600K, 6500K
- Brightness adjusting Range:0%-100%, adjusting step length: 10%
Setting and Use of Communication Address
Long pressing the brightness adjusting button (Fig.6@) about 2s to enter in
communication address setting interface, communication address range:001-512.
LCD digital tube field (Fig.8 ©) flashing indicates that the current bit is
selected, rotate the brightness adjustment knob (Fig.6 ®) to set the current
bit, press the brightness adjustment knob (Fig.6@) to determine the setting of
the current bit and go to the next bit, when the setting of the last bit is
completed, press the brightness adjustment knob (Fig.6@) or wait for about 5
s, to exit the setting of the communication address.
Setting and Use of Communication Control Mode
Through the DMX line of the lamp network, long press color temperature adjustment knob (Fig.6 ®) about 2 s, to complete the lamp communication control mode setting.
- DMX communication model.
LCD upper left corner shows “DMX” (Fig.8 G)) indicates that the current supported communication control mode of the light is DMX communication mode. in this mode, the DMX signal output equipment is connected to the lamp network, and the communication address is set up, which can be used normally.
One panel light takes up 2 DMX control channels. The current set DMX address (N) is the brightness control, and the next set address (N+ 1) is the color temperature control.
For example:**** DMX
Communication address
| ****
DMX
Control channel
| ****
Function
---|---|---
005
| 005| Brightness 0%-100%
006| Color temperature 2700K-6500K
2. lntercontrol Mode
LCD upper left corner shows “CH” (Fig.8@) indicates that the communication
control mode currently supported by the light is mutual control mode. In this
working mode, the target lamp can be set to the same communication address for
normal use without distinguishing between master and slave.
Attention: when using the mutual control function of lamps and lanterns, do
not connect the output equipment of DMX signal in the network of lamps and
lanterns, otherwise this function can not be used normally;
USB interface usage USB interface is reserved interface, please use according to the designated environment of the company’s related products, can not be used for other purposes, so as not to cause losses.
Packing list
Number| Packing list| Portable bag| Engineering
package| Three lights kit(CL- 60D)
---|---|---|---|---
1| CL-60D/CL-120D| X 1| X 1| X 3
2| Power cable| X 1| X 1| X 3
3| Warranty card| X 1| X 1| X 3
4| Light bag| X 1| I| I
5| User manual| X 1| X 1| X 3
6| Adaptor| X 1| X 1| X 3
7| V-mount fastener velcro| Xl{CL-60D)| Xl{CL-60D)| X 3
8| Tripod| I| I| X 3
9| Trolly case| I| I| X 1
10| Ring(Optional)| x 1 (CL-120D)| X 1| I
11| Safety rope (Optional)| X 2 (CL-120D)| x2| I
12| DMX cable (Optional)| ****
Customers can purchase separately on demand
13| Honeycomb (Optional)
Tips: The adaptor and LED PCB board can be changed, the parameters of recommend adaptor are below:
No. | Specification | Parameter |
---|---|---|
1 | DC output socket | 4Pin XLR |
2 | Adapter output power polarity | Pin 111-11,Pin 4″+” |
3 | Working voltage | AC 100-240V, 50/60Hz |
4 | Output voltage | DC12-17V |
5 | Voltage accuracy | ±5% |
6 | Rated Power (Max.) | !SOW |
7 | Power factor | 0.9 |
8 | Working temperature | -10°C-40°C |