Ferono FKM Series FKM160 Duct Fan Installation Guide

June 5, 2024
Ferono

Ferono logo FKM
Duct fan installation direction

**Circular pipe fan installation direction

**

A circular pipe fan is a new design fan, which is combined with domestic and international advanced technology Import pipe’s size is the same as outlet pipe, they are connected directly, to save pipeline design and installation fee. According to aerodynamics, we design a new impeller that can reduce vibration and noise. Apply to the hotel, the guesthouse, the senior hall, and supermarket storage places such as the bathroom, exhaust, return air, wind, and filter. The weight of a single circular pipe blower shall not exceed 20 kilograms, only one person moves round pipe fan easily, and conveniently installation. The circular fan adopted materials meet the RoHS requirement.

Circular pipe fan series main consist of housing, impeller, motor, base, and connection box.

  1. Shell: made from high-quality galvanized steel, which has excellent atmospheric corrosion-resistant performance. Menorca design meets aerodynamics shape to facilitate air into the impeller and convenient installation. Wind and wind using screw connection lid use maintenance and cleaning.
  2. Impeller circular pipe fan adopted new shape plastic impeller both of them are designed by the impeller, in normal operation condition, they can cooperate well with the shell, heavy wind, high efficiency, and low noise. Impeller and exterior rotor motor integral impeller, become the wheel drive motor is the efficiently cold air blower, can prolong life.
  3. Motor: using the phase asynchronous motors. Win the CCC, CE and UL certificates. The motor is characteristic of the impeller directly in the motor shell, being driven directly by motor rotate shell, reasonable structure, mechanical, small volume, saving space. Using three speeds can maintain currents flowing through the way to reduce noise and vibration, automatically reset the thermal protection device, and facilitate power management. Lightweight, smooth operation, high efficiency, long service life.
  4. Junction box: made of ABS materials and flame retardant components, fireproof performance is better. On the surface, the installation and the disassembling connection is very convenient. S

Ferono FKM Series FKM160 Duct Fan

Model| D
(mm)| D1
(mm)| L
(mm)| L1
(mm)| L2
(mm)| F
(mm)
---|---|---|---|---|---|---
FKM100| 100| 237| 204| 25| 25| 42
FKM125| 125| 237| 193| 25| 31| 42
FKM150| 150| 278| 195| 25| 25| 42
FKM160| 155| 278| 215| 30| 28| 42
FKM200| 196| 330| 250| 25| 28| 42
FKM250| 245| 336| 220| 26| 30| 42
FKM315| 315| 402| 265| 30| 25| 42

Notes:

  • This specification describes the fan how is installed used and clean correctly. According to the instructions are used correctly, will ensure good performance, and can fan prolong life.
  • After taking out from the carton of the fan, please check the fan’s appearance and properties No damage or spiral rotor and deformation.
  • If the fan is serious, shall be immediately contacted by qualified personnel who can check the fan properly.
  • Fan receiving requirement: Power and frequency with rated power frequency and consistency. Capacitance can satisfy most high in the fan.
  • Please turn off the power before the fan Maintenance and cleaning. Please turn off the power if the fan needs to move, then dismantle the fan. Put away from the kids will fan or those un-skilled, to ensure safety.
  • Please don’t be this fan is exposed (sunshine, rain, snow, etc), Besides needing cleaning and maintenance, please don’t part of the parts or components fan in other liquids. Clean or routine maintenance please check the fan.
  • To prevent fire, don’t have alcohol, such as gasoline combustibles places. As the gas and air Menorca or other gases must be clean and shall not oily, chemical corrosion elements, inflammable, explosive mixture.
  • Fan when installation should stay away from the main switch, but it must be installed in a separate near fan control fan switch off.
  • To ensure the best operation, with wind and will not Menorca pipe jam.

Installation instruciton

  • Install or move fan must wear gloves or similar protective measures to prevent accidents.
  • According to the method in figure 1, metal buckles will fan ventilation pipe fixed in.
  • Fan hookup sees a terminal box (picture2) after the fan line Connects well. Please send boxes, and then began to fasten the cover.
  • When the fan is for building, please check the rotation direction correctly, current speed, and calibration parameter, the size of the fan does not affect the vibration.

Ferono FKM Series FKM160 Duct Fan - instruciton Maintenance and cleaning

  • The motor and rotor must be periodical, if the fan is an uninterrupted job, about six months a periodic inspection.
  • Fan maintenance must have relevant personnel by the execution.
  • Open junction box cover. Turn off the power to clean and repair the blower. After cleaning please confirm the integrity of the fan, see whether parts all installed.