Ferono FKP100 Plastic Axial Duct Fan Instruction Manual

June 14, 2024
Ferono

Ferono FKP100 Plastic Axial Duct Fan

Product Specifications

  • Model: FKP100, FKP125, FKP150, FKP200, FKP250, FKP315
  • Dimensions:
    • A: 295mm, 170mm, 80mm, 98mm, 204mm, 111mm, 103mm, 60mm
    • B: 295mm, 170mm, 80mm, 122mm, 204mm, 111mm, 103mm, 60mm
    • C: 295mm, 194mm, 80mm, 148mm, 230mm, 126mm, 122mm, 60mm
    • D: 307mm, 203mm, 100mm, 197mm, 240mm, 138mm, 138mm, 75mm
    • E: 380mm, 255mm, 135mm, 247mm, 320mm, 170mm, 146mm, 100mm
    • F: 445mm, 320mm, 185mm, 304mm, 355mm, 195mm, 182mm, 110mm

Product Usage Instructions

Installation

  • Follow the wiring instructions provided for your specific model (FKP100/125 or FKP150/200 or FKP250/315).

Starting Up

  • Ensure the apparatus is securely installed and the electrical connections are correct before starting the machine.

Maintenance

  • Regularly check and maintain the fan to ensure proper functioning.

Recycling

  • Dispose of any leftover materials and packaging in the appropriate recycling containers as per ECC standards.

FAQ

  • Q: How do I determine the correct wiring for my duct fan model?
  • A: Refer to the provided wiring instructions based on your specific model (FKP100/125 or FKP150/200 or FKP250/315).
  • Q: What should I do if the fan is not functioning properly?
  • A: Check the installation and electrical connections to ensure everything is set up correctly. If issues persist, contact our after-sales service or your local dealer for assistance.
  • Q: Is it necessary to perform regular maintenance on the duct fan?
  • A: Yes, regular maintenance is essential to ensure the proper functioning and longevity of the duct fan. Refer to the maintenance instructions in the user manual for guidance.

Wiring instruction

Drawing and Dimensions

Model| A

(mm)

| B

(mm)

| C

(mm)

| øD

(mm)

| E

(mm)

| F

(mm)

| G

(mm)

| H

(mm)

---|---|---|---|---|---|---|---|---
FKP100| 295| 170| 80| 98| 204| 111| 103| 60
FKP125| 295| 170| 80| 122| 204| 111| 103| 60
FKP150| 295| 194| 80| 148| 230| 126| 122| 60
FKP200| 307| 203| 100| 197| 240| 138| 138| 75
FKP250| 380| 255| 135| 247| 320| 170| 146| 100
FKP315| 445| 320| 185| 304| 355| 195| 182| 110

Instruction manual

Thank you for purchasing our products. It has been manufactured following current technical safety regulations and in compliance with EC standards. Please read this instruction carefully before installing or starting up the product. It contains important information on personal and user safety measures to be followed while installing, using, and carrying out maintenance work on the equipment. Once the product has been installed, please hand in this booklet to the end user. Check that the apparatus is in perfect condition while unpacking. Any fault or damage caused in origin is covered by our company guarantee. Please make sure that the apparatus coincides with the product you have ordered and that the details on the instructions plate fulfill your necessities.

Transport and manipulation

  • The packaging user for this apparatus has been designed to support normal transporting conditions. The apparatus must always be transported in its original packaging as not doing so could deform or damage the product.
  • The product should be stored in a dry place in its original packaging, protected from dust and dirt until it is installed in its final location.
  • Do not accept delivery if the apparatus is not in its original packaging or shows clear signs of having been manipulated in any way.
  • Do not place heavy weights on the packed product and avoid knocking or dropping it.

Important information for the safety of installers and user

  • Installation must only be carried out by qualified persons.
  • Make sure that the installation complies with each country’s current mechanical and electrical norms.
  • Once ready to use, the apparatus must fulfill the following standards:
    • Standard for LOW Pressure Installments 2014/35 EU
    • Standard for Electromagnetic Compatibility 2014/30 EU
  • Ventilators, or apparatus that include them, have been designed to move the air in the area stipulated on their characteristics plate.
  • This apparatus must not be used in explosive or corrosive atmospheres.
  • If a ventilator is going to be installed to extract air from premises where a boiler or other combustion apparatus is installed, make sure that the building has sufficient air intake to ensure adequate combustion. The extractor outlet must not be connected a duct used to exhaust smoke or fumes from any appliance that uses gas or any other type of fuel.
  • This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely. Young children should be supervised to ensure that they do not play with the appliance.

Safety during installation

  • Make sure there are no loose elements near the ventilator, as they could run the risk of being sucked up by it. If it is going to be installed in a duct, check that it is clean of any element that could be sucked up by the ventilator.
  • When installing an apparatus, make sure that all the fittings are in place and that the structure that supports it is resistant enough to bear its weight at full full-function ng power.
  • Before manipulating the apparatus, make sure the mains supply is disconnected, even if the machine is switched off.
  • Check that the mains supply voltage and frequency values coincide with the stipulations on the characteristics plate.
  • The electrical installation must include a double pole switch with a contact clearance of at least 3 mm, correctly sized, and under the electrical standards of the country of installation.
  • Please follow the connections diagram for the electrical connections.
  • If an earth connection is necessary, check that it is correctly connected and that adequate thermal and overloading protection has been connected and adjusted to the corresponding limits.
  • If a ventilator is installed in a duct, the duct must be exclusively for the ventilation system.

Starting up

The apparatus is well secured and the electrical connections have been carried out correctly.

  • The safety devices have been adequately connected.
  • No loose material or fitting remains can be sucked up by the ventilator, If the ventilator has been mounted in a duct, make sure it is clear of loose material.
  • The earth fittings are adequately connected.
  • The electrical safety devices are correctly connected, adjusted, and ready for use.
  • The wire and electrical connection inputs are correctly sealed and water-tight.
  • When starting up the machine, make sure that:
  • The propeller turns in the correct direction.
  • There are no abnormal vibrations.
  • If any of the electrical safety devices blow, the apparatus must be quickly disconnected from the main supply. The whole installation should be carefully checked before trying to start up the machine again.

Maintenance

  • Before manipulating the ventilator, make sure it is disconnected from the main supply even if it has previously been switched off.
  • Prevent the possibility of anyone else connecting it while it is being manipulated.
  • The apparatus must be regularly inspected. These inspections should be carried out bearing in mind the machine’s working conditions, to avoid dirt or dust accumulating on the propeller, turbine, motor or grids. This could be dangerous and perceptible shorten the working life of the ventilator unit.
  • While cleaning, great care should be taken not to unstable the propeller or turbine.
  • All maintenance and repair work should be carried out in strict compliance with each country’s current safety regulations.

Recycling

  • According to ECC Standards, together with the responsibility we should assume with future generations in mind, oblige us to recycle all the materials we can. Therefore, please deposit all left-over material and packaging in their corresponding recycling containers and hand in the replaced machines to the nearest handler of this type of waste product.
  • If you have any queries about the products, please contact our after-sales service or your local dealer.

CONTACT

Thermosilesia sp. z o.o. sp. k.

International sales:

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals